BSR Technologies Pvt. Ltd.
- Home
- Companies
- BSR Technologies Pvt. Ltd.
- Products
- BSR - Model UV-6100 / 6300PC - UV ...
BSR - Model UV-6100 / 6300PC -UV Double Beam
UV-6100 / 6300PC is an advanced double beam design, with fixed bandwidth, the two detectors measure sample and reference respectively and simultaneously for optimizing measurement accuracy. They provide excellent performance for measurements in the range of 190 to 1100nm, the memory is 32K. They are suitable for pharmaceutical, biochemical and clinical lab applications as well as routine applications such as quantitative analysis, kinetics, wavelength scan, multiple components and DNA/Protein, PC Windows application software make these instruments versatile. Both instruments provide excellent performance for measurements.
Most popular related searches
DNA concentration
DNA test
DNA testing
photometric
photometric testing
photometric test
pharmaceutical laboratory
- Fixed Bandwidth
- For Stand-alone models, all software methods are included as built-in standard; this eliminates the need of software
- Online software upgrading via internet helps to keep it updated
- Data Download-to- PC software expands the data storage to unlimited
- The stand-alone model has 5 inch screen and the PC model has UVNis Analyst software
- Data can be saved by USB memory device directly
Quantitative Mode
- Up to 10 standard solutions may be used to establish calibration equation curve
- There is a choice of four methods for fitting curve through the calibration points: Linear fit, Linear fit through zero, square fit and cubic fit
Multi-Wavelength Mode
- Up to 10 wavelengths may be entered, allowing the measurement of multiple wavelengths on a series of Samples
Wavelength Scan
- The Wavelength Scan intervals are 0.1, 0.2, 0.5, 1, 2, 5nm, and High, Medium and Low scan speeds are available
- Scan speeds vary from 100 to 3000 nm/min
- Wavelengths are scanned from high to low so that the instrument stand-by at high wavelength, this minimizes the degradation of UV sensitive samples
Kinetics Mode
- This mode may used for scanning time course or reacting rate calculations
- Abs. VS Time graphs is displayed on the screen in real time.
- Wait time and measurement time up to 12 hours may be entered with time intervals of 0.5, 1, 2.5, 10, 30, seconds and 1 min
DNA/Protein Test
- Concentration and DNA purity are calculated by Absorbance ratios 260nm/280nm or 260nm/230nm with optional subtracted absorbance at 320nm
- Photometric Mode
- Quantitative test
- Wavelength Scan
- Kinetics
- DNA/ Protein
- Multi-Wavelength
- System Utility