Use vegetable oil is that it is not flammable, reducing the risk of fire. Reduce energy consumption.

Most popular related searches
  • Transformer Type: Oil immersed
  • Rated capacity: up to 20mva
  • Rated voltage: up to 36kv
  • Frequency: 50/60Hz
  • Phase: 3 Phase
  • Winding material: Copper /Aluminum
  • Tap changer: Off-load or on-load
  • Vector group: YNd1d1
  • Cooling: ONAN /ONAF/ KNAN
  • Ambient temperature:  -20°C to +40°C
  • Dielectric fluids: Mineral oil / Dimethyl Silicone/ Vegetable Oil/
  • Accessories:
    • Bushing
    • Oil level gauge
    • Transformer tank
    • pressure relief valve
    • Tap changer
    • Oil Thermometer
    • Buchholz-Relay

For each transformer are prepared and issued a test report, in accordance with IEC 60076. except for routine tests, we also offer type tests and specialized tests to meet all customer requirements. We make what matters work for our customers in a safe and reliable way.

Routine test

  •  Measurement of winding resistance
  •  Measurement of voltage ratio and check of phase displacement
  •  Measurement of short-circuit impedance and loss
  •  Measurement of no-load loss and current
  •  Dielectric routine tests
  •  Tests on on-load tap-changers, where appropriate
  •  Leak testing with pressure for liquid-immersed transformers(tightness test)
  •  Tightness tests and pressure tests for tanks for gas-filled transformers
  •  Check of the ratio and polarity of built-in current transformers
  •  Check of core and frame insulation for liquid immersed transformers with core or frame insulation

 Type test

  •  Temperature-rise type test
  •  Dielectric type tests
  •  Determination of sound level for each method of cooling for which a guaranteed sound level is specified
  •  Measurement of the power taken by the fan and liquid pump motors
  •  Measurement of no-load loss and current at 90% and 110% of rated voltage

 Special Test

  •  Dielectric special tests
  •  Winding hot-spot temperature-rise measurement
  •  Determination of capacitances windings-to-earth, and between windings
  •  Measurement of dissipation factor(tanδ) of the insulation system capacitances
  •  Determination of transient voltage transfer characteristics
  •  Measurement of zero-sequence impedance(s) on three-phase transformers
  •  Short-circuit withstand test
  •  Measurement of d.c. insulation resistance each winding to earth and between windings
  •  Vacuum deflection test on liquid immersed transformers
  •  Pressure deflection test on liquid immersed transformers
  •  Vacuum tightness test on site on liquid immersed transformers