TEK 3000
  1. Companies
  2. TEK 3000
  3. Products
  4. MKIII - Model MK-III - Weather Station ...

MKIIIModel MK-III -Weather Station with Rain Gauge

SHARE

This version of the MK-III has the gauge connected to the back of the MK-III. The advantage of this season is that the sensors are centralized in a single compact unit. This version of the MK-III has the gauge connected to the back of the MK-III. The advantage of this season is that the sensors are centralized in a single compact unit and does not need battery gauge. The only requirements are that the MK-III station is properly aligned vertically for adjusting the gauge.

Most popular related searches

Anemometer - wind speed

Scale: 0-67 meters / sec; 0-240 km / h; 0-130 knots.

Resolution: 1.0 unit

Accuracy: + -2% scale principle.

Veleta-Wind direction

Scale: II Display Oracle 16 points display with  LED, while the direction comes from one point he  led flashes indicating the current wind direction. With the CC2000 datalogger indicates the direction in degrees.

Example: 360 = North, SE = 220 ° ..... etc.

Temperature

Scale: from -54 to + 74 ° C; -66º To 166º F

Resolution: 1 whole unit at Oracle and tenths.

(0.1) in datalogger CC2000.

Accuracy: + -0.5 ° C, + - 1 ° F.

RH

Scale: 0 to 100% RH

Resolution: 1 unit.

Accuracy: + - 2% to 25ºC.Compensanción.

temperature-40C to + 85C.

Dew point

Scale: - 40 to + 60 ° C.

Resolution: 1 whole unit at Oracle and tenths.

(0.1) in datalogger CC2000.

Accuracy: + - 1 ° C, + -2 F.

Wind-chill factor

 Scale: -80 ° C, 127 ° F.

Resolution: 1 whole unit at Oracle and decimas.

(0.2) in datalogger CC2000.

Accuracy: + -1 ° C, 1 ° F.

Barometer-Atmospheric Pressure:

 Scale: from 551 to 1084 millibars (hPa).

Accuracy: + - 1.69 millibars (hPa) Compensation.

temperature 40 ° to 85 ° C.

Precipitation Pluviómetro-

Scale: Unlimited capacity, diameter of the mouth.

20.32cm rain gauge.

Resolution: 0.25 mm.

Accuracy: + - 2% to 25.4 mm / h.

Transmission

 Range: 50 to 200 meters, depending on the location and structure of the walls.

 Transmission frequency: 433MHz. Certified CE, FCC.

Antenna: omnidireccionable Integrated.

Agency consulted: CTMS Cambridge Test & Mesurament.

Services Ltd.

Measurements 

C ensor MKIII-WS2000, Interface, solar panel: 25x38x71 cm.

Scale: 0-67 meters / sec; 0-240 km / h; 0-130 knots.

Resolution: 1.0 unit

Accuracy: + -2% scale principle.

Veleta-Wind direction

Scale: II Display Oracle 16 points display with  LED, while the direction comes from one point he  led flashes indicating the current wind direction. With the CC2000 datalogger indicates the direction in degrees.

Example: 360 = North, SE = 220 ° ..... etc.

Temperature

Scale: from -54 to + 74 ° C; -66º To 166º F

Resolution: 1 whole unit at Oracle and tenths.

(0.1) in datalogger CC2000.

Accuracy: + -0.5 ° C, + - 1 ° F.

RH

Scale: 0 to 100% RH

Resolution: 1 unit.

Accuracy: + - 2% to 25ºC.Compensanción.

temperature-40C to + 85C.

Dew point

Scale: - 40 to + 60 ° C.

Resolution: 1 whole unit at Oracle and tenths.

(0.1) in datalogger CC2000.

Accuracy: + - 1 ° C, + -2 F.

Wind-chill factor

 Scale: -80 ° C, 127 ° F.

Resolution: 1 whole unit at Oracle and decimas.

(0.2) in datalogger CC2000.

Accuracy: + -1 ° C, 1 ° F.

Barometer-Atmospheric Pressure:

 Scale: from 551 to 1084 millibars (hPa).

Accuracy: + - 1.69 millibars (hPa) Compensation.

temperature 40 ° to 85 ° C.

Precipitation Pluviómetro-

Scale: Unlimited capacity, diameter of the mouth.

20.32cm rain gauge.

Resolution: 0.25 mm.

Accuracy: + - 2% to 25.4 mm / h.

Transmission

 Range: 50 to 200 meters, depending on the location and structure of the walls.

 Transmission frequency: 433MHz. Certified CE, FCC.

Antenna: omnidireccionable Integrated.

Agency consulted: CTMS Cambridge Test & Mesurament.

Services Ltd.

Measurements 