Onset - Model InTemp CX402-TXXX -Wireless Temperature Data Logger with Glycol
InTemp CX402-TXXX (with Glycol Bottle) data loggers monitor temperatures in refrigerators, freezers and other temperature-controlled environments. The loggers communicate wirelessly via Bluetooth Low Energy to mobile devices. Using the InTemp app, you can easily view data, check logger status, set alarms, and create and share secure PDF reports for streamlined reporting and regulatory compliance. All loggers feature a built-in LCD display to view current and daily min and max temperatures, advanced audible and visual alarm capabilities for notification of temperature excursions, an internal sensor for ambient temperature monitoring, and a NIST Certification of Calibration. Models are available with a 2- or 4-meter external temperature probe attached to a Glycol bottle used to insulate the probe and delay thermal response times.
Who is this for?
The InTemp CX402-Txxx data logger (with probe in glycol) is right for you if:
- You work for an organization that’s required to primarily follow GDP/GMP, FDA, USP, and/or EU/CE guidelines for monitoring ambient to frozen temperatures
- Your organization is a pharmaceutical manufacturer, third-party logistics company, Life Science/Biotech storage and transportation company, or other organization looking to monitor temperature-sensitive goods
- You need a 1-Year NIST-certified data logger (probe and ambient temperature sensor), as recommended by the previously mentioned regulatory bodies
Required to follow GDP & GMP requirements, specifically:
- Probe in glycol
- GDP/GMP compliant
- Frozen to ambient monitoring
To see the full specifications for this product, please see our product manual found under the documentation tab if available.
Logger
Radio Power 1 mW (0 dBm)
Transmission Range Approximately 30.5 m (100 ft) line-of-sight
Wireless Data Standard Bluetooth Low Energy (Bluetooth Smart)
Logger Operating Range -30° to 70°C (-22° to 158°F), 0 to 95% RH (non-condensing)
Logging Rate 1 second to 18 hours
Time Accuracy ±1 minute per month at 25°C (77°F)
Battery Type Two AAA 1.5 V alkaline or lithium batteries, user replaceable
Battery Life 1 year, typical with logging interval of 1 minute. Faster logging intervals, remaining connected with the InTemp app, excessive report generation, numerous audible alarms, and paging all impact battery life.
Memory 128 KB (84,650 measurements, maximum)
Full Memory Download Time Approximately 60 seconds; may take longer the farther the device is from the logger
LCD LCD is visible from 0° to 50°C (32° to 122°F); the LCD may react slowly or go blank in temperatures outside this range
Dimensions 9.4 x 4.5 x 2.59 cm (3.7 x 1.77 x 1.02 inches)
Weight 90.2 g (3.18 oz)
Environmental Rating IP54
CE The CE Marking identifies this product as complying with all relevant directives in the European Union (EU).
External Temperature Probe
Range -40° to 100°C (-40° to 212°F)
Accuracy ±0.5°C from -15° to 80°C (±0.9°F from 5° to 176°F), ±1.0°C from -40° to -15°C (±1.8°F from -40° to 5°F), ±0.7°C from 80° to 100°C (±1.3°F from 176° to 212°F)
Resolution 0.024°C at 25°C (0.04°F at 77°F)
Drift <0.1°C (0.18°F) per year
Response Time With 5 mL bottle: 10 minutes typical to 90% in air moving 1 m/s, With 15 mL bottle: 20 minutes typical to 90% in air moving 1 m/s, With 30 mL bottle: 25 minutes typical to 90% in air moving 1 m/s
Cable Length 2 or 4 meter (6.56 or 13.12 feet) flat ribbon cable
Ambient Temperature Sensor
Range -30° to 70°C (-22° to 158°F)
Accuracy ±0.5°C from -15° to 70°C (±0.9°F from 5° to 158°F), ±1.0°C from -30° to -15°C (±1.8°F from -22° to 5°F)
Resolution 0.024°C at 25°C (0.04°F at 77°F)
Drift <0.1°C (0.18°F) per year
Response Time 15 minutes typical to 90% in air moving 1 m/s
- Integrates with mobile and cloud platforms for a 21 CFR Part 11 compliant solution
- Easy-to-read display with current and daily min/max temperatures
- Bluetooth transmission of data and alarm states
- Logger setup and download of data in seconds – without a PC or cable
- Real-time alerts and automatic data downloads with optional CX Gateway device
- +/- 0.5C accuracy for reliable temperature readings
- Battery-powered to guard against local power loss
- Several Glycol bottle/probe-only options available
- Includes 1-year NIST calibration, per USP guidelines