Y2K - Model FD-5 - Vacuum Dehydration System
The purpose of the FD-5 Vacuum Dehydration System is to serve as an oil treatment system. By removing water (dissolved, emulsified and free), gasses and solid contaminants the oil can return to its original condition, and be reused in lubricating systems. Having clean, dry oil will allow hydraulic and lubricating systems to perform more efficiently and can result in significant financial gains. The need to purchase new lubricating oils can be reduced and in some cases eliminated completely.
Products Details
To begin, the oil is brought into the chamber and passed over the heater and heated. It then is dispersed over the Pall Rings , located inside the tower, and then exposed to a vacuum, usually between 22-25”Hg.
After the oil has been degassed and dehydrated it is pumped out of the bottom of the tower via the hydraulic pump into the filter to remove any contaminants before it enters the reservoir or system again.
In order to optimize this process the FD-5 Purifier is partially automated with a PLC and series of electrically controlled switches. Data, diagnostics, alerts and many help screens can be accessed on the control panel touch screen display.
Typical Applications:
- Filtering Pulp and Paper lube systems
- Filtering steam turbine lube systems
- Filtering hydraulic reservoirs
- Filtering rolling mill lube tanks
- And many other industrial applications containing oil
Specification
- Flow Rate 5 GPM
- Vacuum Pump Flow Rate 13 CFM
- Heater Capacity 3KW @ 15wsi
- Motors Electric, 480 VAC, 3 Phase
- Plumbing Requirements Inlet: 1-1/2' NPT; Outlet: 1-1/4' SAE
- Approximate Dry Weight 950 lbs
- Dimensions 44.5'L x 30.5'W x 68'H
- Start Up Bypass Standard
- Condenser Optional
- Water Monitor Standard
- Chamber Pall Dispersion Rings; never have to get in chamber to change filter elements
- Chamber Vacuum Adjustable; Ideal range is 22-27' Hg
- Fluid Temperature Factory set at 145°F and is adjustable up to 165°F
- Filtration 1 ea - 6x18 Filter Element
- Seal Material(s) Buna N, Viton, EPDM or EPR
- Max Fluid Viscosity ISO 680 or 4250 SUS
- Inlet Pressure Maximums 10'Hg Vacuum to 15psig
- Outlet Pressure 65psig Max
- Continuous Heater Flow Minimum 2-5 GPM continuous flow through heater to prevent oil coking
Customer reviews
No reviews were found for Y2K - Model FD-5 - Vacuum Dehydration System. Be the first to review!