Hangzhou Chunlai Technology CO., Ltd.

ZetianModel FT-3000 -Fourier Transform Infrared Spectroscopy (FTIR) Continuous Emission Monitoring System

SHARE

FT-3000 flue gas emission continuous monitoring system is an advanced equipment which adopts in-situ extractive FTIR analyzing technology. It works in the way of full-time high-temperature heat tracing (thermal wet method), and can accurately measure a variety of flue gas components, including SO2 , NOX (NO, NO2 ), HCl, CO, O2 , humidity, temperature, pressure, and flow rate and other parameters.

Most popular related searches
  • Multi-component measurement: simultaneous monitoring of SO2 , NOx (NO, NO2 ), CH4 , HCl, HF, CO, CO2 , N2 O, H2 O, O2 , etc.
  • Strong anti-interference: non-linear least squares iterative algorithm, effectively avoiding cross-interference between components and influence of water vapor;
  • FTIR technology: wide spectral range, multiple measurable components, wide measurement range, low detection limit, able to meet a variety of requirements;
  • High-temperature heat tracing of 180? throughout the whole process to avoid inaccurate measurement caused by flue gas condensation and crystallization;
  • Other parameters and factors expandable according to actual needs.
  • The innovative design and multifaceted analytical capabilities of the FT-3000 continuous flue gas emission monitoring system make it a reliable and comprehensive monitoring solution, widely used in industrial emissions and environmental monitoring.
  • Parameters: SO2 , NO, NO2 , CO2 , H2 O, HCl, HF, CH4 , CO (FTIR), O2  (zirconia)
  • Power supply: AC (220±22)V; (50±1)Hz
  • Rated power: ≈ 5000W (heat tracing pipe included)
  • Ambient temperature: 15℃~35℃ (indoor); -20℃~50℃ (outdoor)
  • Ambient humidity: ≤ 85%RH, non-condensing
  • Heat tracing temperatur: 180ºC
  • Flow rate: 2L/min
  • Indication error: ?2.5%F.S.
  • Repeatability: ≤2%
  • Zero drift: ≤2.5%F.S./d
  • Span drift: ≤2.5%F.S./d
  • Response time: ≤200s