Zero Gravity Filters Inc.
  1. Companies
  2. Zero Gravity Filters Inc.
  3. Products
  4. ZGF - Model MG100 - Maggie Magnetic ...

ZGFModel MG100 -Maggie Magnetic Separator 1-Core

SHARE

Body: Stainless steel 304L. Magnet: Permanent, rare earth, neodymium iron boron. Magnetic tube: Stainless steel 316L. Ball Valve: Outlet/Purge: ¾” 3-way ball valve. The valve has a stainless steel 316 body and ball with PTFE seats. Actuator: Double acting, developing 300 in/lb at 80 psi. Manufactured by Assured Automation, size PD045. Connections: Inlet: ¾” MNPT. Outlet/Purge: ¾” FNPT. O-rings: Viton standard.

Most popular related searches

Controls

  • Electrical Timer Adjustments for purge duration and purge interval between 10ms and 99 hours.
  • Manual purge push button. Housing made of ABS plastic, NEMA 4 (IP65) rated.
  • Air Solenoid Valve ASCO direct mount 24 VDC or 120 VAC
  • Air Manifold Block Aluminum

Site Requirements

  • Air Supply 70 to 80 psi, clean and dry. ¼” air supply connection. Required air flow is 8
  • standard cubic feet per minute (scfm).
  • Electrical Supply 24 VDC or 120 VAC
  • Pneumatic Pipework ¼” pneumatic flexible tubing with push-in connectors.
  • Approximate Dimensions and Weight
    • 4.5 x 7 x 21” (116 x 176 x 532 cm).
    • Dry: 10 lbs, Wet: 11.5 lbs (4.5, 5.2 kgs)
  • Fluid Volume 0.25 gallons

  • Number of Magnetic Shuttles 1 per unit.
  • Flowrate
    • 12 gpm (45 LPM), maximum with water-based fluids.
    • 8 gpm (45 LPM), maximum with oil (30 cSt at 40ºC).
  • Operating Pressures 75 psi (517 kPa), maximum. 25 psi (172 kPa/0.17 mPa), minimum. 125 psi (862 kPa) test pressure.
  • Operating Temperature 170ºF (75ºC) maximum.
  • Backwash Control Automatically using electrical timer or manually using push button.
  • Energy Consumption (per purge) Air: .42 cubic feet (rotate valve and shuttle Maggie)
  • Electrical: 2.5 watts
  • Purge Volume 1.0 gallon (5 seconds at 12 gpm)