DJA Inspection Services
  1. Companies
  2. DJA Inspection Services
  3. Services
  4. API 510 Internal Inspections Services

API 510 Internal Inspections Services

SHARE

Complete inspection following API-510 Out-of Service inspection checklist. Thickness reading on shell plates. Thickness reading on heads. Visual inspection with photographs and/or a record of any visible defects. Thickness reading on all accessible nozzles. Magnetic particle test nozzle welds and bottom-to-shell weld (or corner box) if tank is properly prepared. Shell layout drawings. Nozzle layout drawings. Layout of defects. Post inspection meeting to discuss findings. Recommendations and/or observations. Summary of inspection findings. Final formal report.