Maintenance and Inspections Services
Schust provides customers with the most comprehensive preventative maintenance and inspection services to keep air pollution control (APC) systems running as intended. Customers trust Schust because, with over 30 years of experience, they know services are performed by knowledgeable technicians.
With our extensive technical and application experience, Schust provides turnkey services you can’t find anywhere else. Your APC system is thoroughly inspected, and if any repairs are needed, Schust can also supply the parts and installation per the final written report. Preventative maintenance and inspection services can be scheduled to fit your time frame.
The professionals at Schust inspect and repair Scheuch filtration and exhaust gas cleaning equipment that is in use in North America. As part of the Scheuch Group, Schust can offer the world-class, locally sourced service that Scheuch clients have been accustomed to. Find out more about the collaboration between Scheuch and Schust.
A Preventative Maintenance Inspection Typically Includes:
- Conduct system air volume measurements and calculations to determine operating performance.
- Inspect the collector discharge hopper, augers, and rotary valves.
- Check the photohelic and maghelic pressure gauges for proper zero function. Re-set as needed.
- Verify and record the pressure drop across the filters.
- Measure and record fan inlet static and RPM.
- Visual inspection of the general condition of the system(s).
- Ultraviolet leak inspection to locate any leaking filter media.
- Visual inspection of tube sheets, venturis, and blowpipes
- Inspect the cleaning system, including pulse valves, solenoid valves, compressed air pressure, and timer settings.
- Inspect fans, including housings, bearings, and drives.
- Inspect access door seals for leaks.
- OSHA Confined Space Entry program, air monitoring equipment, and attendant
- A written report of each inspection includes the following information:
- Current physical condition of collector(s) and system components.
- Tubesheet layout drawings indicate the location of repaired or defective pulse valves, blowpipes, leaking filter media, and venturies on all baghouse units.
- Tracking of the system air volume, static and velocity pressure, filter pressure, and current test data
- A list of recommended repairs.