Listen Button: Press Listen. The DLD audio processor turns on and listens for sound from the accelerometer.
Most popular related searches

Press Volume. Volume level range is 1 to 29. (Default is 15.)
To select the desired volume:
• Press once to increase the sound by one step.
• Hold down the Volume button to increase DLD volume to the desired level.
The DLD automatically turns off if a button is not pressed for 90 seconds.
Press the Filters button to select the desired precision filter setting:
- SEr Service lines
- Con Hydrants, valves, etc.
- SUr Survey work (default)
- OPn No filter settings
- Gnd Ground listening all surfaces (asphalt, soil, etc.)
Setting Frequency (Hz)
Open 100 - 1800
Ground 100 - 400
Service 250 - 800
Contact 300 - 1800
Survey 150 - 750
While listening, the LCD shows the Leak Analysis number (the detected leak sound level).