Envicomply - ECATT, Inc.
Florida UST Class A/B Certification Program (9 Modules)
This course has been reviewed and approved by the Florida Department of Environmental Protection (DEP). Successfully completing this training will award a certificate which grants UST Class A/B operator certification in Florida.
Most popular related searches
underground storage tank
spill prevention
secondary containment sump
cathodic protection
secondary containment
petroleum spill
emergency response
tank secondary containment
float valve
spill detection
This training course covers the following information:
Module 1: UST Operator Training Requirements
- State UST program requirements
- Operator requirements and training records
- Manning facilities
Module 1A: Class A Operators
- UST Class A and C operator responsibilities and training requirements
- Retraining and documentation
Module 1B: Class B Operators
- UST Class B and C operator responsibilities and training requirements
- Retraining and documentation
Module 2: Underground Storage Tanks
- What an underground storage tank (UST) is
- What tanks qualify as USTs
- Common tank construction materials
- Product compatibility
- Acceptable methods for meeting compatibility requirements
- Tank venting
- Secondary containment
- Sumps
Module 3: Spill and Overfill Prevention
- Why spill prevention is important
- Correct UST filling practices
- Spill prevention equipment
- Spill buckets
- Spill prevention requirements
- Overfill protection devices
- Automatic shutoff devices
- Overfill alarms
- Ball float valves
- Overfill prevention requirements
Module 4: Release Detection
- Why release detection is important
- Automatic tank gauging (ATG) systems
- ATG regulatory requirements
- ATG leak tests that must be performed monthly
- Inventory control
- Common inventory control problems
- Secondary containment with interstitial monitoring
- Interstitial monitoring devices
- Under-dispenser containment (UDC)
- Visual inspections
- Spill detection inspections
Module 5: Corrosion Control
- Corrosion protection requirements
- Cathodic protection
- Cathodic protection testing and recordkeeping
- Interior lining
Module 6: UST Financial Requirements
- Who is responsible for demonstrating financial responsibility
- What tanks are not covered by the financial responsibility requirements
- How to demonstrate financial responsibility
- UST financial responsibility categories
- Financial responsibility for different sets of tanks
- Required dollar amount of financial responsibility
- The required scope of coverage
- General recordkeeping/reporting requirements
- When is coverage no longer necessary
Module 7: Temporary and Permanent Tank Closure
- Facility registration
- Delivery prohibition programs
- Closing a tank temporarily
- Closing a tank permanently
Module 8: Emergency Response
- UST release response
- What constitutes a suspected release
- Requirements for reporting releases
- Interim spill/leak response actions
- Spill/leak long-term actions
- Spill containment materials
- Basic steps to follow when responding to a petroleum spill
- Washing down spills
- Spills reaching water
- Large spills
- Additional information resources
Module 9: Inspections, Recordkeeping, and Reporting
- Tank handling and inspection requirements
- Records that must be available for review
- What records must be kept and for how long