Celdar Technology - Fluorides Removal in Lithium Battery Recovery Industry - Case Study
Jul. 14, 2023
Courtesy ofIntecna srl
To design a wastewater treatment plant, the customer asked us to evaluate the ELECTROCOAGULATION for the removal of Fluorides, to be able to avoid corrosion phenomena in installed electrical and mechanical
Most popular related searches
fluoride removal
zero liquid discharge
wastewater treatment plant
wastewater treatment plant engineering
electrocoagulation process
electrocoagulation system
wastewater treatment
electrocoagulation
wastewater plant
zero discharge
- Location: NORTH EUROPE
- PRODUCED WASTEWATER: 40 cubic meter/hour
- Typical problems in wastewater: High Fluorides, Sulphates, COD
TREATMENT PRINCIPLES AND AIMS
Another option required was the ZERO LIQUID DISCHARGE and therefore the possibility of reusing the treated water with the least amount of consumption possible.
This option is possible using an ELECTROCOAGULATION PLANT since no chemicals are used and therefore the physical and chemical characteristics of the water to be treated have little variation compared to the treated water.
The obtained results and working conditions are below
- TYPICAL ANALYSIS PARAMETERS
- Achieved results (first image)
- https://www.replicait.it
ELECTROCOAGULATION PROCESS PARAMETERS
- Number of electrodes: 36
- Type of alloy: CELDAR
- Volt applied: 7
- AMPERES: 48
- Reaction time: 2 hours
- Temperature: 48 °C
- Final treatment: Flocculation