NovaCHROM Gas Chromatographs

AGC NovaCHROM - Gas Chromatograph Analyser System

Introducing the AGC NovaCHROM 1000 GC System using our world-famous Discharge Ionisation Detector (DID). This type of GC is used to measure trace levels of impurities within a sampled gas across a wide range of applications from ppm down to ultra-low ppb levels. Impurities such as H2, Ar, O2, N2, CH4, CO, CO2, N2O, C2H2, C2H2, C2H2, Kr, Ne, Xe, CF4, C2F6, SF6, SiH4, SiH3Cl, SiHCl3, SiCl4, SiH2Cl2 …etc. are some typical impurities that can be measured, the list is exhaustive and please contact AGC Instruments if you have a specific impurity and we can examine this further and devise a solution.

AGC NovaCHROM - Gas Chromatograph Analyser System

Introducing the NovaCHROM 2000 GC System which has been specifically designed for the Analysis of Trace Impurities in an Argon Matrix Gas. It utilises our proprietary Argon Discharge Detector (ADD) which is a plasma emission detector to enable low levels to ppb of H2, O2, N2, CH4, CO, CO2 & N2O in quality control for an Argon sample gas. This detector has also proven to be very effective in the analysis of specific impurities in CO2 and is being utilised in many CO2 production sites world-wide. The NovaCHROM 2000 GC uses Argon as a carrier gas which offers many benefits over alternative methods.

AGC NovaCHROM - Gas Chromatograph Analyser System

Introducing the NovaCHROM 2000 GC System which has been specifically designed for the Analysis of Trace Impurities in an Argon Matrix Gas. It utilises our proprietary Argon Discharge Detector (ADD) which is a plasma emission detector to enable low levels to ppb of H2, O2, N2, CH4, CO, CO2 & N2O in quality control for an Argon sample gas. This detector has also proven to be very effective in the analysis of specific impurities in CO2 and is being utilised in many CO2 production sites world-wide. The NovaCHROM 2000 GC uses Argon as a carrier gas which offers many benefits over alternative methods.

AGC NovaCHROM - Gas Chromatograph Analyser System

Introducing the NovaCHROM 4000 GC System which is ideal for permanent gas analysis and its universal applicability ensures that it is both cost effective and reliable. The NovaCHROM 4000 GC contains the latest GC technology based on using an industry proven detector. The AGC Thermal Conductivity Detector (TCD) is world famous. Experts in this detector since 1965, we have developed many variations of the TCD to suit our own applications and those from other GC manufacturers all over the world. We pride ourselves of being about to measure from single ppm figures to 100% concentration, this universal detector has remained a steadfast in our company where many companies also purchase it as an OEM solution for their own use.

IGC NovaCHROM - Gas Chromatograph Analyser System

Introducing the NovaCHROM 5000 GC System which has been specifically designed for the quantification and identification of Sulphur based components in a sample stream. The NovaCHROM 5000 GC contains the latest GC technology based around the industry proven Flame Photometric Detector (FPD). This rugged detector design, of which AGC Instruments has extensive experience, is ideal for both cost effective and reliable gas analysis. Utilising the latest advanced technologies, this GC provides customers with the precise results they require where the measurement and quantification of any sulphur related compounds are required. Typical impurities range from H2S, SO2, COS, CS2, Methyl Mercaptans, Ethyl Mercaptans…etc. depending on the application and background gas.

Others

AGC NovaCHROM - Gas Chromatograph System

The NovaCHROM 9000 ASU is the newest range of Gas Chromatograph Systems from AGC Instruments. Developed specifically for Air Separation Units to cover a wide range of process applications, each NovaCHROM 9000 GC System is custom made to suit the application. The AGC Engineering team will design an analytical solution specific to your requirements using a selection of industry-proven Detectors for which we are a leading supplier worldwide. With an array of ancillary instrumentation to provide a turn-key systems, the NovaCHROM 9000 ASU offers precision, robustness and a long working life.

AGC NovaPRO - Process Gas Chromatograph (PGC) System

Introducing the newest On-Line Gas Chromatograph for the Process market from AGC Instruments. The NovaPRO 9000 Process Gas Chromatograph (PGC) utilises the most up-to-date technology and systems available. This advanced PGC provides custom solutions for a wide range of industries and offers 24-hour monitoring and reporting as needed. Accurate readings are achieved using our range of proven detectors which have been perfected over 50 Years of experience. This Ex approved PGC utilising a Purge method (Ex p) conformity, is housed in a mild steel enclosure that is purged for use in the harshest of environments and suitable for use in Zone 1 and Zone 2 classified areas.

NovaAIR Gas Chromatographs

NovaAIR - Flame Ionisation Detector (FID) System

The NovaAIR 3000 GC System, using the Flame Ionisation Detector (FID) is primarily used for Hydrocarbons analysis. It is used in many applications including ambient air monitoring or industrial hygiene applications such as Methane / Non-Methane / BTEX Hydrocarbon Analysis which is increasingly coming to the forefront as many countries and companies wish to reduce their carbon footprint. Therefore, this application satisfies the governmental environmental regulations introduced in many countries by monitoring emissions to the atmosphere. The NovaAIR GC is based on tried and tested technologies with in-depth reporting back to Control Room, DCS or environmental agencies available. Due to its small footprint, the room required is minimal and provides a big advantage where space is a premium.

AGC NovaAIR - Thermal Conductivity Detector (TCD) System

The NovaAIR 4000 GC System, using the Thermal Conductivity Detector (TCD) is used for the precise analysis of the components in multiple gas mixtures at percentage and ppm levels. The NovaAIR GC is based on tried and tested technologies with in-depth reporting back to Control Room or DCS available. Some of the applications include measuring Helium in Neon, Argon and Nitrogen in Oxygen, ppm impurities in Argon and Nitrogen Pharmacopeia to name but a few. Due to its small footprint, the room required is minimal and provides a big advantage where space is a premium. The TCD is a universal detector, of which AGC Instruments is a leading supplier world-wide has been honed for a wide range of applications using the new NovaAIR GC system platform.

NovaSTREAM 6000 Gas Analysers

AGC NovaSTREAM - Wall Mount Gas Analyser System

The NovaSTREAM 6000-TCD Analyser is explosion proof utilising an ‘Ex p’ Purge method of conformity, and is housed in a mild steel enclosure for use in the hazardous areas of Zone 1 and Zone 2 classification. This specially designed enclosure enables real-time analysis in hazardous areas with reliable and consistent results.