B & B Chlorination
Production of dry pellet chlorinators for treating water problem.
Company details
Find locations served, office locations and our distributors
- Business Type:
- Manufacturer
- Industry Type:
- Drinking Water
- Market Focus:
- Nationally (across the country)
About Us
It would be nice if all wells delivered sparkling clear, good tasting water straight from the ground.
Unfortunately, many wells contain naturally occurring minerals that can cause the following:
- Reddish or orange stains on plumbing and fixtures.
- Black or gray stains on fixtures.
- Premature plugging of pumps and water treatment equipment.
- Metallic, iron taste in water.
Well water also may become contaminated with bacteria that can result in:
- Slimy, red or black deposits on pumps, filters and water treatment equipment.
- Embarrassing 'rotten egg odor'.
- Disease in humans or livestock.
- Reduced water pressure.
- Increased maintenance costs.
Treat Problem Water with B&B's Dry Pellet Chlorinators
Many water problems, such as iron, manganese, hydrogen sulfur and iron bacteria, begin in the well. Doesn't it make sense to tream them there? The MARK III treats well water before it gets to your house. Early sanitation results in:
- Better filtration of iron and manganese
- Reduced staining
- Control/elimination of nuisance bacteria
How a Dry Pellet Chlorinator Works
A dry pellet chlorinator is a device that mounts on the well and drops a compressed chlorine tablet down the well shaft into the well water. It is wired into the pump's electrical circuit and runs whenever the pump is pumping water, metering chlorine in proportion to water usage. An adjustment mechanism accounts for variations in pump sizes and water quality. As the pellet sinks to the bottom of the well and dissolves in the water, it releases chlorine that reacts with contaminants in the well. The chlorine OXIDIZES iron and manganese ions, preventing staining and allowing more efficient filtration, and SANITIZES contaminants like hydrogen sulfur, iron bacteria, algae, etc. preventing further growth.
Advantages of B&B Chlorinators
- Only one moving part, means low maintenance
- Easy to fill hopper
- Easy adjustment to any chlorine level
- Field Serviceable
- User Friendly
- Clear design to view operation and pellet level
What Will it Treat?
Hydrogen Sulfide Bacteria
Iron Bacteria
Manganese
Coliform Bacteria
Iron
Algae and Pond Scum
Hydrogen Sulfide Bacteria
Hydrogen Sulfide is a by-product of a sulfur-feeding bacteria and is noted by its distinct smell. Rotten egg, sulfur, and sewer gas are common descriptions. It is also accompanied by black slimy build up that can cause many of the same problems as iron bacteria.
Iron Bacteria
Iron Bacteria is most noticeable by the slimy red coating it leaves in the water system. Severe cases can plug pumps and pipes, increase operating costs, and lead to premature pump failure. Low water pressure is a common symptom of severely plugged pumps and pipes. Water-conditioning equipment (softeners, filters) can become plugged easily, leading to frequent service calls and inconsistent operation. Stains on porcelain fixtures, (i.e. tubs, showers stalls, etc.) are common. On the farm, waterers can be coated with a red or black slime, which can discourage livestock from drinking and promote more bacteria growth.
Manganese
Manganese is characterized by black to grayish deposits, or black water with a metallic taste. Chemically, its treatment is similar to iron. Manganese appears in the same forms and exhibits the same problems. While not as common as iron, it will show up at much lower levels: .05 ppm is enough to cause problems. Dissolved manganese is slower to oxidize than iron so early chlorination is helpful. Unlike iron, any build ups in pipes are difficult to remove, so ignoring the problem can lead to more expense in the future.
Coliform Bacteria
Coliform bacteria si the standard used in well testing. Coliform is present in many warm-blooded animals as a normal part of the digestive tract. Its presence in a water supply is an indication that animal or human waste is making its way into a water supply. Coliform bacteria has no detectable smell or taste. The coliform itself may not be a problem, but is an indicator that other pathogenic bacteria may be present. These bacteria can cause disease such as typhoid, cholera, hepatitis, giardiasis, and dysentery. Although these are common in many underdeveloped countries, the lack of these diseases in the United States is largely attributed to the chlorinated water supply.
Because chlorine is a sanitizer, it will kill these bacteria id applied properly. In laboratory conditions, chlorine at 1ppm residual takes 20 minutes contact time to achieve 100% kill of coliform bacteria. If the bacteria is exposed for less time or at lower levels, it may still be present when the water is consumed. By dropping dry pellets into the well, treatment is started at the earliest possible time, and in most cases, the 20-minute mark will be met. Testing is the only way to confirm the effectiveness of chlorination. If bacteria is still present, a higher level of chlorine or more retention time through the addition of holding tanks may be necessary.
Iron
Because 5% of the earth's crust is iron, it is no surprise that many wells contain it in various amounts. It takes just a trace of iron to cause problems: as little as .2ppm can stain plumbing, fixtures, and laundry. In larger amounts, water can become rust colored and have a metallic taste. Iron can coat the insides of pipes with hard, red scale, which reduces flow rates and plugs filter screens.
Because iron is found in different forms the treatment can vary.
- Ferrous iron is dissolved and appears clear out of the tap. At lower levels, it can be removed by ion exchange (water softening), but if iron bleed through occurs(red stains, rusty water, etc.), it may have to be oxidized and filtered
- Ferric iron is oxidized (precipitated) and appears red out of the tap. It consists of particles in the 30- to 50- micron range and will pass through most water softeners. An iron filter will probably be needed.
- Heme iron is iron bound up with organic material (often referred to as tannins). It needs to be oxidized by chlorine to destroy the bond between the organic material and iron to precipitate the iron out of the solution.
- Iron bacteria needs to be sanitized and the precipitated iron filtered.
Ferrous iron and iron bacteria occur most often.By pre treating with Dry Pellet Chlorination, the different types of iron can be converted to ferric which can be filtered. Adequate contact time is necessary, since the iron may not precipitate immediately, especially if it is bound up with tannins or iron bacteria. Generally, 30 minutes are thought to be sufficient. Over time, continuous chlorination will remove built up iron deposits from plumbing.
Algae and Pond Scum
Shallow wells and water drawn from ponds may be contaminated with surface runoff and biological debris from both plants and animals. Ponds are particularly prone to this since they contain numerous forms of life that can be drawn easily into the pump. These contaminants can be filtered out physically, but the water should be sanitized for human or livestock consumption and for aesthetic and health reasons. Whether they are pathogenic or not can be determined only by a test, but these types of water sources are subject to many variables affecting their quality.