Model ULTRIX 100 - Ultrasonic Level Transmitter
Loop Powered - 2 wire, 4-20 mA output, Choice of ranges up to: 10, 17, 26, 33, or 50 feet, Intrinsically safe versions, Chemically resistant TeflonĀ® nose section, Nema 6 submersible, IP68, CE certified
Contegra - Model GPX 100 - Gauge Pressure Transmitter
Gauge pressure sensor that`s easily panel mounted. Choice of outputs: 0.5 - 4.5 VDC, 4-20 mA loop powered. Choice of ranges: 5, 10, 15, 30 PSI.Model FS 202 - Dry Well Float Switch
PVC, PBT and Buna N construction for chemical resistance. Selectable, N.O. or N.C. by inverting float on unit stem. Reed switch for reliable extended service. Large float displacement for lower specific gravity liquids.
Station Master 500 - Pump Controllers
Duplex, Triplex or Quadraplex Pump Control. Constant Speed or Variable Speed Control. First On / First Off Pump Alternation. Running Time Meters. Pump Start Counters. Failed Pump Replacement. Accepts 4-20 mA, 0-10 VDC, 0-5 VDC analog input. 0-10 VDC Variable Speed Output. SM500 Series is Pump-down, SM600 is Pump-up.Station Master 2000 - Duplex Pump Controller
User-friendly graphical interface. Ultra-bright daylight viewable LEDs for all setpoints and configuration information. Sealed front, door mounted. Pump Up of Pump Down operation. Isolated analog input. 4 solid state triac outputs, individually fused. Level simulation. SCADA ready, Modbus protocol.CA-2PDA - Pump Controller
Primary analog control of duplex constant speed pump applications. Redundant float control. Abnormal Level output and Alarm Silence input. Pump Running Time Meters and Pump Start counters. Pump alternator sequence selection inputs.CD-2 - Pump Controllers & Protector
Simplex / Duplex pump control. High Alarm output with silence. Monitor output. Pump alternation sequence selection . Model CD-2R Redundant Controller. Redundant control in a duplex pump application as a backup to an analog controller. Timed `lag on` and `off delay` when applied with a single alarm float . Model CD-2P Duplex Control - Primary control for a duplex pump station.Sensors
Model SLX 130 - Submersible Level Transducer
The SLX 130 Submersible Level Transducer is typically used to monitor the level of sewage wet wells, chemical tanks, streams, clearwells, ground storage tanks and other liquid level-sensing applications. The SLX 130`s large 2.5` diameter Teflon(R) faced diaphragm is an excellent choice for liquids with a high concentration of suspended solids.
Model SLX 160 - Submersible Level Transducer
The SLX 160 Submersible Level Transducer is typically used to monitor the level of sewage wet wells, chemical tanks, streams, clearwells, ground storage tanks or other applications with low-to-moderate suspended solids.
Model SLX 220a & SLX 220b - Submersible Transducers
The SLX 220a and SLX 220b submersible transducers consist of two components; a level transmitter (i.e. the SLX 130-E) and a current transmitter (i.e. the T425 or T423 respectively).