Forestry Suppliers, Inc.
215 products found
Forestry Suppliers, Inc. products
Electronic Stream Flow Meter
Revolutions of impeller are sensed electronically and transmitted to a hand-held counter unit that features start, stop, and clear functions. Revolutions per unit of time can be translated into stream velocity using a conversion chart. May be used in brackish water or salt water. Fitted with a re-settable LCD counter, this flowmeter eliminates the need for tiresome calculations. Comes complete with PVC pole mounted with an impeller which collapses into four sections for easy storage and carrying, three stream bed elevation rods, protective carrying pouch for counter, weather-proof storage case, instruction manual, and comparison charts. Optional 3-cup, hand-held anemometer is available for use with the flowmeter for measuring air velocity. Range of the anemometer is 2 mph to 65 mph. Materials: PVC impeller poles, stainless steel impeller shaft, plastic impeller. Dimensions: Overall pole length: 3.3´. Four individual sections: 9.8ý each. Cable: 3.3´. Elevation rods: 9.8ý, 4.9ý, and 2.5ý. Data Readout: LCD counter; 800 counts per minute; re-setting. Sensor Type: Magnetic. Range: Approximately 0.05m/sec to 8.0m/sec. Accuracy: ±7%. Power: 2 AAA batteries (included).Specific Gravity Hydrometer
Designed to measure ratio density of liquid at 60°F to the density of water at 60°F. Specific gravity range: 1.000 to 1.070. Graduations: .0005 with ±.005 accuracy. Requires hydrometer jar (53630), sold separately.EcoBailer - Pro Big Mouth Bailers
Designed to sink rapidly without creating turbidity in the well sample, the EcoBailer Pro features a “big mouth” hydrodynamic design that creates less drag during descent and minimizes dissolved oxygen in the well sample. The easy-to-handle emptying device allows for greater control of liquid flow into a sample bottle, and the EcoBailer Pro’s pour spout and ball retainer also allow for easy pouring from the top of the bailer. Cleaned to EPA standards and individually packaged. Choose from weighted or non-weighted clear PVC bailers. Case of 24.Waterproof pH 52 Tester
Accurate waterproof pH/°C tester has a double junction replaceable pH glass electrode which allows it to be used in heavy-duty applications such as waste water treatment and agriculture. The pH52 is housed in an IP67 waterproof case and features automatic temperature compensation and auto shut-off after 8 minutes. Operating Environment: -5° - 60°C/100% RH. pH: Range: -2.0 - 16.0 pH. Resolution: 0.1 pH. Accuracy: ±0.1 pH. Calibration: Automatic, 1 or 2 points. Temperature: Range: -5.0° - 60.0°C. Resolution: 0.1°C. Accuracy: ±1°C. Battery: three 1.5V. Battery Life: 200 hours of continuous use.Global Water Composite/Discrete Water Sampler
This composite/discrete sampler allows you to control sample size and take either individual, time-weighted composite samples or full-bottle discrete grab samples in a two-gallon sample bottle. You can set the time between individual composite samples or use the external trigger mode for flow-proportional sampling. Use the start delay timer to start multiple samplers in the field at the same time or delay drawing a water sample following a triggering event so that the sample better represents the water source. The automatic 15 second backflush cycle ensures that the next composite sample is not contaminated. Sample size can be adjusted to one of 15 composite sample sizes from 50 ml to 2 liters, and the time interval can be set to one of 15 time settings from 5 minutes to 12 hours. Comes complete with a two-gallon polyethylene sample bottle, a peristaltic sampling pump, a circuit board controller, a sample pickup hose, a rechargeable gel cell battery, and a battery charger. Specifications Sample Size: Composite, 50 ml to 2 liter samples as set by user. Two gallon composite sample maximum. Size: 9˝D X 17˝W X 22˝H. Weight: 20 lbs. Operating Temperature: 0°C to 70°C. Materials: Enclosure, Expanded UV protected by PVC; Bottle, 2 gallon polyethylene; Sample Tubing, Polyethylene. Sample Pump: Flow Rate, 1,000 mL per minute at 4 ft. head; Type, Peristaltic; Maximum Lift, 20´. Logic Timer/Controller: CMOS Solid State (fully potted in epoxy). Sample Hose: One 15´ PVC reinforced 1/4˝ ID polyethylene flexible tubing section with intake strainers. Hoses may be extended, as required, using standard 1/4˝ tubing and fittings. Battery: Rechargeable 5 AH Gel Cell. Battery Life: one hour, continuous pumping under load; standby, three months while still retaining enough power to run the pump to capacity.Smart Water Analysis Laboratory
This complete, portable lab kit measures 24 water quality parameters for pollution detection, environmental studies, and industrial water and wastes. The digital SMART2 Colorimeter analyzes test sample color reactions and provides direct readouts for 15 factors. Two Direct Reading Titrators that provide titration results directly in ppm for six additional factors are also included in the kit. This digital meter features automatic temperature compensation and measures pH with a range of 0-14, and conductivity in three ranges: 0-19.99 µS/cm, 200-1,999 µS/cm, and 2.00-19.99 mS/cm. Also includes 15 reagents and five titrator tests. Reagents Included In Lab Kit Factor Method Range (# Tests) Ammonia Nesslerization 0-3.0 ppm (50) Chlorine DPD 0-4.0 ppm (100) Bromine DPD 0-10 ppm (100) Iodine DPD 0-15 ppm (100) Chromium (Hexavelent) Diphenylcarbazide 0-1.0 ppm (100) Copper Diethyldithiocarbamate 0-5.0 ppm (100) Fluoride SPADNS 0-2.0 ppm (50) Iron Bipyridyl 0-5.0 ppm (50) Nitrate Cadmium Reduction 0-3.0 ppm (20) Nitrite Diazotization/Coupling 0-0.7 ppm (20) Phosphate Ascorbic Acid Reduction 0-3.0 ppm (50) Silica Heteropoly Blue 0-4.0 ppm (50) Sulfate Barium Chloride 0-100 ppm (50) Sulfide Methylene Blue 0-3.0 ppm (50) Turbidity Absorption (No Reagents) 7-400 NTU (Unlimited) Direct Reading Titrator Tests Included In Kit Factor Method Range (# Tests) Alkalinity Neutralization 0-200 ppm (50 at 200 ppm) Carbon Dioxide Neutralization 0-50 ppm (50 at 50 ppm) Chloride/Salinity Argentometric 0-200 ppm (50 at 200 ppm) Dissolved Oxygen Azide Modification of Winkler Method 0-10 ppm (50 at 10 ppm) Hardness (Calcium, Magnesium, and Total) Complexometric 0-200 ppm (50 at 200 ppm)Shallow Water Test Kit
Turbidity is measured by direct comparison of sample water to turbidity standards selected to match formazin standards. Also allows you to accurately test for dissolved oxygen, temperature, pH, and turbidity. Measures dissolved oxygen from 0 to 10 ppm; readable to 0.1 ppm. Thermometer measures temperature from -5°C to +45°C in 0.5° increments. Two octet comparators are used to measure pH from 3.0 to 10.5 in 0.5 increments.Coliform Test Kit
A simple five-tube method to indicate the presence or absence of Total Coliform Bacteria in drinking water. No incubation equipment required. Highly portable, no accessory labware required. Ideal test for well water and coliform breakthrough in distribution systems. Results compare favorably to five-tube MPN method. Includes five glass tubes marked at 10 ml level and containing one Coliform Test Tablet. Sterile water sampling bag with dechlorinating tablet is included for chlorine removal. Performs one test only.Environmental Test Kits
Innovations in comparator methods permit the detection of extremely low levels of many water factors that previously could not be detected colorimetrically. Each outfit includes the necessary test reagents, glassware, accessories and full instructions for conducting the chemical analysis covered by the kit. Refill reagents and replacement parts are available for all units – call for details. Each set is furnished in a carrying case.CHEMets - Water Test Kits
Designed for low-to-medium-range colorimetric analysis, each kit includes 30 prescored ampoules filled with reagents sealed under vacuum, color comparators, a snap cup, and instructions to perform 30 tests.
