IMR Environmental Equipment, Inc.

65 products found

Products

  • Portable Combustion Gas Analyzers

  • IMR - Model 1100F - Vehicle Emissions Analyzer for CO

    IMR - Model 1100F - Vehicle Emissions Analyzer for CO

    The exhaust gas analyzer IMR1100F is designed to measure exhaust gases for vehicle emissions. The analyzer measures the Carbon Monoxide CO content in volume percent as requested by European and worldwide regulations. The measured CO value can be saved or printed. The analyzer comes complete with a flexible probe, IR-printer, additional printer paper (printer and paper only in IMR1100-F/KIT) and a carrying case. The flexible probe, which fits in most...

  • IMR - Model 1400-compact - 2-4 Cell Compact Flue Gas Analyzer

    IMR - Model 1400-compact - 2-4 Cell Compact Flue Gas Analyzer

    Measures: O2, CO, NO, NO2 (SO2); draft/pressure; soot; Flue-gas and ambient temperature. Calculates:CO2, combustion efficiency, heat losses, excess air, CO corrected. Comes with gas-sampling probe, condensation trap, rugged case, battery. Built-to customer specification.

  • IMR - Model 1400-IR - 3-4 Cell Flue Gas Analyzer (Measures CO2)

    IMR - Model 1400-IR - 3-4 Cell Flue Gas Analyzer (Measures CO2)

    Measures: CO2 (NDIR), O2, CO, NO, NO2 (SO2); draft/pressure; soot; Flue-gas and ambient temperature. Calculates:Combustion efficiency, heat losses, excess air, CO corrected. Comes standard with gas-sampling probe, condensation trap, rugged case,battery, printer, CO-bypass, serial interface, memory, 12VDC.

  • IMR - Model 1400P/PL/PS - 2-4 Cell Flue Gas Analyzer for the Professional

    IMR - Model 1400P/PL/PS - 2-4 Cell Flue Gas Analyzer for the Professional

    Measures: O2, CO, NO, NO2 (SO2); draft/pressure; soot; Flue-gas and ambient temperature. Calculates:CO2, combustion efficiency, heat losses, excess air, CO corrected. Comes standard with gas-sampling probe, condensation trap, rugged case,battery, printer, CO-bypass, serial interface, memory, 12VDC.

  • IMR - Model 1400CO - 2x CO-Sensors - Flue Gas Analyzer For The Professional

    IMR - Model 1400CO - 2x CO-Sensors - Flue Gas Analyzer For The Professional

    Measures: O2, CO-low (in ppm), CO-high (in %), draft/pressure; soot; Flue-gas and ambient temperature. Calculates:CO2, combustion efficiency, heat losses, excess air, CO corrected. Comes standard with gas-sampling probe, condensation trap, rugged case,battery, printer, Automatic CO-bypass-switch, serial interface, memory, 12VDC.

  • IMR - Model 1440FL/COFL - Exhaust Gas Analysis for Forklift Trucks

    IMR - Model 1440FL/COFL - Exhaust Gas Analysis for Forklift Trucks

    The exhaust gas analyzer, IMR1440FL/COFL, is designed to measure exhaust gases of Forklift Trucks that are powered by a variety of fuels. According to US regulations, the IMR 1440FL/COFL can measure soot and CO for Forklift Trucks. If state regulations require NOx, the IMR 1440FL/COFL can be equipped with a NOx sensor. The IMR 1440COFL is equipped with two CO sensors. One CO sensor operates in the low range and another CO sensor operates in the high...

  • IMR - Model 2000/2800-IR - 4-9 Cell IR-Flue Gas Analyzer

    IMR - Model 2000/2800-IR - 4-9 Cell IR-Flue Gas Analyzer

    Measures: O2, CO, CO2, NO, NO2, SO2, HC; draft/pressure; soot; Flue-gas and ambient temperature. Calculates: Heat losses, excess air. Comes standard with gas-sampling probe, condensation trap, rugged case,battery, printer, serial interface, memory.

  • IMR - Model 1020 - Combustion Gas Analyzer

    IMR - Model 1020 - Combustion Gas Analyzer

    The IMR 1020 enables HVAC professionals to accurately test and service all residential combustion appliances. The extra-large backlit LCD displays two parameters at one time. Easily choose the desired combustion parameter with the rotary selector. The optional printer allows you to print your readings to document your test results.

  • IMR - Model 1400–FO - Combustion Gas Analyzer

    IMR - Model 1400–FO - Combustion Gas Analyzer

    The combustion gas analyzer IMR 1400 FO is easy to use, compact and rugged. One CO-sensor is installed for high CO-measurements. This helps to get the best possible accuracy for different applications (e.g. wood fired applications or forklifts).

  • Continuous Flue Gas Monitoring System

  • IMR - Model H2-200 - Hydrogen Analyzer

    IMR - Model H2-200 - Hydrogen Analyzer

    Easy to use menu driven interface. High accuracy H2 analysis. Uses thermal conductivity to measures gas concentration. 0 -30% or 50%~100% H2 FS ranges.

  • IMR - Model 5000 - Continous Flue Gas Monitoring System

    IMR - Model 5000 - Continous Flue Gas Monitoring System

    The IMR 5000 is state-of-the-art continuous flue-gas monitoring system, and is designed for a wide variety of flue-gas monitoring applications. The IMR 5000 is a stand-alone analyzer that works automatically. Available in a 19' rack mount or rugged wall mounted enclosure. The wall mount enclosure meets NEMA type 4X (IP65) standards. The modular approach of the IMR 5000 allows multiple gases (up to 12 gases) to be measured simultaneously. The IMR 5000...

  • Zirconia Oxygen Analyzer

  • IMR - Model 6400 - Zirconia Oxygen Analyzer

    IMR - Model 6400 - Zirconia Oxygen Analyzer

    IMR 6400 intelligent oxygen analyzer uses an advanced anti-interference circuit and an anti-volatile data protection function. The display will automatically switch to any range for the set limit concentration on the alarm. The IMR 6400 series analyzer is a new kind of intelligent industrial instrument. It can test the oxygen content in the kiln on line, analyze, and do the comparison in order to achieve a low oxygen burning control and ensure a safe...

  • Open Path Infrared Methane Gas Analyzer

  • IMR - Model 8000 - Open Path Infrared Gas Detector

    IMR - Model 8000 - Open Path Infrared Gas Detector

    Measures: Methane (CH4). High accuracy, sensitivity, and selectivity of Methane. With out interference by other gases. Resistant to the sun, water, sand, wind and shock. Long life span and low maintenance cost.

  • Portable Ambient Gas Detectors

  • IMR - Model IX616 - Multi Gas Detector

    IMR - Model IX616 - Multi Gas Detector

    Continuous detection of combustible and toxic gases. High quality sensor that detects gases via diffusion. Durable case suitable for any environment.

  • Gas-Conditioning Systems

  • Automotive Flue Gas Analyzers

  • IMR - Model 2800-A - Gas Analyzer for Automotive Emissions

    IMR - Model 2800-A - Gas Analyzer for Automotive Emissions

    Gas analyzer for automotive emissions; Latest sensor technology for a more accurate measurement and a longer life time. Improved interior design for easier service and better unit protection. Measures up to 8 gases. Larger display for better reading. Increased memory. Latest NDIR-technology to measure CO, CO2 and HC. Applications: Cars, Trucks, Motorcycles,  Engines, Turbines, Cogeneration plants .

  • Forklift Emissions, Truck, Engine, Turbine

  • IMR - Model RPM Meter - Automotive Multimeter

    IMR - Model RPM Meter - Automotive Multimeter

    This automotive multimeter allows you to measure AC/DC voltage, dwell angle and ENGINE RPM from the comfort of your own garage. With the large easy-to-read LCD display, readings are clearly visible even in low-light settings. Functions on this automotive multimeter include diode test, HFT auto range, resistance measurement, capacitor test, Ohm, tach, low battery, auto zero, continuity and temperature.

  • Measuring Instruments

  • IMR - Model RLD10 - Refrigerant Leak Detector

    IMR - Model RLD10 - Refrigerant Leak Detector

    Adjustable tick rate. Long 18' (45cm) flexible gooseneck. Automatically detects all existing refrigerants and blends. Audio and visual tick rate. Fast response time (< 1 second).

  • Other

  • IMR - Calibration Gas Kit

    IMR - Calibration Gas Kit

    Standard features of the kit include; Calibration hose. Carrying case with shoulder strap (58 liter size only). Regulator for disposable calibration gas cylinder, stainless steel, fixed flow rate 1.5 liter/min.

  • IMR - RIGO Elements - Angular Vice Jaws

    IMR - RIGO Elements - Angular Vice Jaws

    Automaticly centers rectangular workpeices up to a 1:3 ratio. Concentricity and lateral guiding accuracy > 0.02mm. Double Vee block surface for fast and safe clamping. 16MnCr5, case hardened and polished.

  • Obsolete/Discontinued Parts

  • IMR - Model DT150 / DT200 - Digital Thermometer

    IMR - Model DT150 / DT200 - Digital Thermometer

    The DT150 / DT200 digital thermometers accept type J, K or T probes to accommodate your existing process technology. Its backlight displays are easy to read, even in low-light areas. The DT200 allows you to measure two inputs simultaneously.

  • IMR - Model DI-148 U - Starter Kit

    IMR - Model DI-148 U - Starter Kit

    The DI-148U breaks new ground in price and performance, offering advanced features usually reserved for more expensive instruments. They include, but are not limited to, a channel scan list, high sample rate throughput, and an advanced computer interface. These features combine to produce a robust instrument that can be  Applied to nearly any data acquisition situation where pre amplified signals need to be acquired to a PC.

  • IMR - Model DustAlert 60 - Continuous Particulate Monitor

    IMR - Model DustAlert 60 - Continuous Particulate Monitor

    The DustAlert 60 is a continuous particulate monitor for emission control and arrestment plant performance monitoring. Utilising an advanced design Electrodynamic measurement technique, this single channel monitor with dual alarm outputs and scaleable 4-20mA has proven monitoring capabilities and German TA LUFT accreditation.

  • Ambient Gas Detectors

  • IMR - Model 901A-CO2 - Gas Detectors for Carbondioxide

    IMR - Model 901A-CO2 - Gas Detectors for Carbondioxide

    Measuring range: (0~5000)ppm, (0~5)%vol, (0~10)%vol, (0~100)%vol. Resolution ratio: lppm/0.01%vol. Display: Liquid crystal display(LCD) display. Response time: 7SdB. Alarm light: >20m visible. Alarm point: Fully adjustable. Alarm method: Sound, light. Continuous working time: >3 months ( without backlight). Sensor lifetime: £5 year. Working current: < 1mA ( without backlight). Working temperature: -25~55°C, short time: -40~55°C....

  • IMR - Model 901A-CO - Gas Detectors for Carbonmonoxide

    IMR - Model 901A-CO - Gas Detectors for Carbonmonoxide

    Measuring range: (0n00)ppm;(0~1000)ppm, (0~10000)ppm. Resolution ratio: lppm. Display: Liquid crystal display(LCD) display. Response time: 75dB. Alarm light: >20m visible. Alarm point: Fully adjustable. Alarm method: Sound, light. Continuous working time: >3 months ( without backlight). Sensor lifetime: >2 year. Working current: < 1mA ( without backlight). Working temperature: -25~55°C, short time: -40~55°C. Battery:...

  • IMR - Model 901A-O2 - Gas Detectors for Oxygen

    IMR - Model 901A-O2 - Gas Detectors for Oxygen

    Measuring range: (0~25)%vol, (0~30)%vol. Resolution ratio: 0.1%vol. Display: Liquid crystal display(LCD) display. Response time: *35s(T90). Alarm sound intensity: >75dB. Alarm light: >20m visible. Alarm point: Fully adjustable. Alarm method: Sound, light. Continuous working time: >3 months ( without backlight). Sensor lifetime: ?>2 year. Working current: < 1mA ( without backlight). Working temperature: -25~55°C, short time:...

  • IMR - Model 901A-H2S - Gas Detectors for Hydrogen Sulphide

    IMR - Model 901A-H2S - Gas Detectors for Hydrogen Sulphide

    Measuring range: (0~50)ppm,(0~100)ppm,(0~1000)ppm. Resolution ratio: lppm. Display: Liquid crystal display(LCD) display. Response time: *45s(T90). Alarm sound intensity: >75dB. Alarm light: >20m visible. Alarm point: Fully adjustable. Alarm method: Sound, light. Continuous working time: >3 months ( without backlight). Sensor lifetime: ?>2 year. Working current: < 1mA ( without backlight). Working temperature: -25~55°C, short time:...

  • IMR - Model 901A-SO2 - Gas Detectors for Sulphur Dioxide

    IMR - Model 901A-SO2 - Gas Detectors for Sulphur Dioxide

    Measuring range: (0~20)ppm, (0~50)ppm. Resolution ratio: O.lppm. Display: Liquid crystal display(LCD) display. Response time: *45s(T90). Alarm sound intensity: >75dB. Alarm light: >20m visible. Alarm point: Fully adjustable. Alarm method: Sound, light. Continuous working time: >3 months ( without backlight). Sensor lifetime: ?>2 year. Working current: < 1mA ( without backlight). Working temperature: -25~55°C, short time:...

  • IMR - Model 901A-NO - Gas Detectors for Nitrogen Monoxide

    IMR - Model 901A-NO - Gas Detectors for Nitrogen Monoxide

    Measuring range: (0~100)ppm,(0~250)ppm. Resolution ratio: O.lppm. Display: Liquid crystal display(LCD) display. Response time: 3 months ( without backlight). Sensor lifetime: z2 year. Working current: < 1mA (without backlight). Working temperature: -25~55°C, short time: -40~55°C. Battery: PL123450, 3.7V/1500mA. Charging time: 4-5 hours. Protection degree: IP54. Size & Weight: 105*54*32mm/450g.

  • IMR - Model 901A-NO2 - Gas Detectors for Nitrogen Dioxide

    IMR - Model 901A-NO2 - Gas Detectors for Nitrogen Dioxide

    Measuring range: (0~100)ppm,(0~250)ppm. Resolution ratio: O.lppm. Display: Liquid crystal display(LCD) display. Response time: 3 months ( without backlight). Sensor lifetime: z2 year. Working current: < 1mA (without backlight). Working temperature: -25~55°C, short time: -40~55°C. Battery: PL123450, 3.7V/1500mA. Charging time: 4-5 hours. Protection degree: IP54. Size & Weight: 105*54*32mm/450g.

  • IMR - Model 901A-CL2 - Gas Detectors for Chlorine

    IMR - Model 901A-CL2 - Gas Detectors for Chlorine

    Measuring range: (0~100)ppm,(0~250)ppm. Resolution ratio: O.lppm. Display: Liquid crystal display(LCD) display. Response time: 3 months ( without backlight). Sensor lifetime: z2 year. Working current: < 1mA (without backlight). Working temperature: -25~55°C, short time: -40~55°C. Battery: PL123450, 3.7V/1500mA. Charging time: 4-5 hours. Protection degree: IP54. Size & Weight: 105*54*32mm/450g.

  • IMR - Model 901A-H2 - Gas Detectors for Hydrogen

    IMR - Model 901A-H2 - Gas Detectors for Hydrogen

    Measuring range: (0~100)ppm,(0~250)ppm. Resolution ratio: O.lppm. Display: Liquid crystal display(LCD) display. Response time: 3 months ( without backlight). Sensor lifetime: z2 year. Working current: < 1mA (without backlight). Working temperature: -25~55°C, short time: -40~55°C. Battery: PL123450, 3.7V/1500mA. Charging time: 4-5 hours. Protection degree: IP54. Size & Weight: 105*54*32mm/450g.

  • IMR - Model 901A-NH3 - Gas Detectors for Ammonia

    IMR - Model 901A-NH3 - Gas Detectors for Ammonia

    Detecting gas : Ammonia (NH3), Measuring range: (0~100)ppm, (0~1000)ppm. Resolution ratio: lppm. Display: Liquid crystal display(LCD) display. Response time: *45s(T90). Alarm sound intensity: >75dB. Alarm light: >20m visible. Alarm point: Fully adjustable. Alarm method: Sound, light. Continuous working time: >3 months ( without backlight). Sensor lifetime: ?>2 year. Working current: < 1mA (without backlight). Working temperature:...

  • IMR - Model 901A-O3 - Gas Detectors for Ozone

    IMR - Model 901A-O3 - Gas Detectors for Ozone

    Detecting gas : Ozone (O3) ; Measuring range: (0~5)ppm, (0~100)ppm. Resolution ratio: O.lppm. Display: Liquid crystal display(LCD) display. Response time: *45s(T90). Alarm sound intensity: >75dB. Alarm light: >20m visible. Alarm point: Fully adjustable. Alarm method: Sound, light. Continuous working time: >3 months ( without backlight). Sensor lifetime: ?>2 year. Working current: < 1mA ( without backlight). Working temperature:...

  • IMR - Model 901A-LEL - Gas Detectors for Combustible Gas

    IMR - Model 901A-LEL - Gas Detectors for Combustible Gas

    Detecting gas : Combustible Gas (LEL); Measuring range: (0~100)%LEL. Resolution ratio: 1%LEL. Display: Digital diode (LED) display. Response time: 75dB. Alarm light: >20m visible. Alarm point: Fully adjustable. Alarm method: Sound, light. ( ontinuous working lime: >10h( without backlight). Sensor lifetime: *1 year. Working current: < 1mA (without backlight). Working temperature: -25~55°C, short time: -40~55°C. Battery: PL123450,...

  • IMR - Model 901A-CH4 - Gas Detectors for Methane

    IMR - Model 901A-CH4 - Gas Detectors for Methane

    Measuring range: ( 0.00~4.00 ) %CH4, (0~100)%CH4. Resolution ratio: 0.01%CH4. Display: Digital diode (LED) display. Response time: 75dB. Alarm light: >20m visible. Alarm point: Fully adjustable. Alarm method: Sound, light. Continuous working time: >10h( without backlight). Sensor lifetime: >lyear. Working current: < 1mA ( without backlight). Working temperature: -25~55°C, short time: -40~55*C. Battery: PL123450, 3.7V/1500mA. Charging...

  • IMR - Model 901A-CH4-IR - Gas Detectors for Methane (CH4 IR)

    IMR - Model 901A-CH4-IR - Gas Detectors for Methane (CH4 IR)

    Measuring range: ( 0.00^5000) ppmCH4, (0.00-5.00) %CH4, (0~100)%CH4. Resolution ratio: 0.01%CH4. Display: Digital diode (LED) display. Response time: 75dB. Alarm light: £20m visible. Alarm point: Fully adjustable. Alarm method: Sound, light. Continuous working time: >10h( without backlight). Sensor lifetime: £l year. Working current: < 1mA (without backlight). Working temperature: -25~55°C, short time:  40~55°C. Battery:...

  • IMR - Model 902A-CH4-CO2 - Gas Detectors for CH4, C02

    IMR - Model 902A-CH4-CO2 - Gas Detectors for CH4, C02

    Measuring range: ( 0.00^5000) ppmCH4, (0.00-5.00) %CH4, (0~100)%CH4. Resolution ratio: 0.01%CH4. Display: Digital diode (LED) display. Response time: 75dB. Alarm light: £20m visible. Alarm point: Fully adjustable. Alarm method: Sound, light. Continuous working time: >10h( without backlight). Sensor lifetime: £l year. Working current: < 1mA (without backlight). Working temperature: -25~55°C, short time:  40~55°C. Battery:...

  • IMR - Model 903A-CH4-CO2-H2S - Gas Detectors for CH4, C02, H2S

    IMR - Model 903A-CH4-CO2-H2S - Gas Detectors for CH4, C02, H2S

    Measuring range: CH4:(0~100)%vol C02: (0~100)%vol H2S:(0~1000)ppm. Resolution ratio: CH4: l%vol H2S:lppm C02: l%vol. Display: Liquid Crystal Display(LCD). Response time: CH4: S70S ( T90 ) CO2:20M visible. Alarm point: Fully adjustable. Continuous working time: >13hours. Working current: 80mA. Sensor lifetime: ;>5years(CH4,C02) 5>2years(H2S). Battery model: PL123450,3.7V/1500mA. Charging time: 4-5 hours. Protection degree: IP65. Size &...

  • IMR - Model 904A-CH4-O2-H2S-CO - Gas Detectors for CH4, 02, H2S, CO

    IMR - Model 904A-CH4-O2-H2S-CO - Gas Detectors for CH4, 02, H2S, CO

    Measuring range: CH4: (0.00-5.00)°/oVol 02: (0~30.0)%vol, (0~100)%vol H2S:(0~100)ppm CO: (0~1000) ppm. Resolution ratio: CH4: 0.01%vol, 02: 0.1%vol H2S:lppm, CO: lppm. Display: Liquid Crystal Display(LCD). Response time: CH4: *20S (T90 ), 02: *35s(T90), H2S:<45S(T90),CO:75dB; >20M visible. Alarm point: Fully adjustable. Continuous working time: *12hours. Working current: 95mA. Sensor lifetime: *2year( CO, 02, H2S) *lyear(LEL,  ...

  • IMR - Model 904A-LEL-O2-H2S-CO - Gas Detectors for LEL, O2, H2S,CO

    IMR - Model 904A-LEL-O2-H2S-CO - Gas Detectors for LEL, O2, H2S,CO

    Measuring range: CH4: (0.00-5.00)°/oVol 02: (0~30.0)%vol, (0~100)%vol H2S:(0~100)ppm CO: (0~1000) ppm. Resolution ratio: CH4: 0.01%vol, O2: 0.1%vol H2S:lppm, CO: lppm. Display: Liquid Crystal Display(LCD). Response time: CH4: *20S (T90 ), O2: *35s(T90), H2S:<45S(T90),CO:75dB; >20M visible. Alarm point: Fully adjustable. Continuous working time: *12hours. Working current: 95mA. Sensor lifetime: *2year( CO, O2, H2S) *lyear(LEL, CH4). Battery...

  • Analyzer - Gas Conditioning Systems

  • Flue Gas Conditioning Systems

  • IMR - Model 550P - Combustion Gas Dryer

    IMR - Model 550P - Combustion Gas Dryer

    The IMR 5 5 Op device is for the cleaning of gases and is suitable for use in conjunction with all gas measuring and analysis instruments.It is encased in a handy portable case. It is especially designed for use with the IMR 1400 and IMR 2800 series or any other type of combustion gas analyzer. The dust free gas is led directly to the IMR550P via heated tube without being cooled. Leading the gas through a tube, the outside of that has dry gas...