Chiller/Chilled System - Low Temperature Refrigeration Circulators

LNEYA - Model LT -45℃~30℃ - Low Temperature Cooling Recirculating Water Chiller

To save water resources, it is possible to use the glycol-water mixture to carry out circulating refrigeration, strict circulation pipeline design, prevent circulating water pollution, and prolong the use time of circulating water; Original imported compressor, overlapping supercooled refrigeration technology; Double condensation high efficiency system; Computer cascade temperature controller, temperature digital display, adjustment unit 0.1 degree, PT100 temperature sensor, -125 degrees ~ -20 degrees wide temperature range; Ambient temperature monitoring function to prevent the system operating environment temperature from being too high; It adopts full-closed design, no water absorption during low-temperature operation, ensuring the purity of cold and heat-conductive medium, preventing ice crystals and improving the life of thermal fluid. view more: https://www.lneya-online.com/industrial-water-chiller/

LNEYA - Model LT -60℃~-20℃ - Glycol Refrigeration Circulator

The use of ethylene glycol and water mixture for circulating refrigeration, saving water resources; using subcooling technology to ensure temperature stability at low temperatures; using a fully enclosed design to ensure the purity of cold and heat transfer medium, preventing ice crystals, and improving the life of thermal fluid; A high-performance circulating pump that boosts the ability to work 24 hours a day; using high-quality and efficient panels.

LNEYA - Model LT -80℃~-20℃ - Low Temperature Refrigeration Cycle System

The use of ethylene glycol and water mixture for circulating refrigeration, saving water resources; using subcooling technology to ensure temperature stability at low temperatures; using a fully enclosed design to ensure the purity of cold and heat transfer medium, preventing ice crystals, and improving the life of thermal fluid; A high-performance circulating pump that boosts the ability to work 24 hours a day; using high-quality and efficient panels.

LNEYA - Model LT -105℃~-60℃ & -120℃~-70℃ - Water-cooled Refrigeration Circulator

To save water resources, it is possible to use the glycol-water mixture to carry out circulating refrigeration, strict circulation pipeline design, prevent circulating water pollution, and prolong the use time of circulating water;

LNEYA - Model LX -25℃~30℃ - Double Condensing Circulator

To save water resources, it is possible to use the glycol-water mixture to carry out circulating refrigeration, strict circulation pipeline design, prevent circulating water pollution, and prolong the use time of circulating water;

TCU (Multi-Reactor Chiller)

LNEYA - Model SR TCU - Single Fluid Heat Transfer Temperature Control System

Excellent performance, high precision, intelligent temperature control, very wide temperature control range, from -120 ° C ~ 350 ° C, suitable for most enterprises temperature control needs. Product temperature control accuracy of ± 0.5 ° C, cooling power from 0.5 kW to 1200 kW can provide the corresponding products.

LNEYA - Model ZLF TCU - Reactor Material Temperature Control System

TCU temperature control system USES the existing heat (such as steam, cooling water and cryogenic liquid - the "primary") system infrastructure are integrated into the single fluid system was used to control the temperature of process equipment or in the secondary loop.This achieves only one type of heat transfer liquid can flow into the jacket of the reaction vessel (not directly flow into steam, cooling water or ultra-low temperature liquid).The temperature of the whole reaction process is controlled by operation.

Cooling&Heating Temp Control System - Dynamic Temperature Control Systems

LNEYA - Model SUNDI-320/420W/430W - Chiller System

Change the control settings of the method, the response as soon as possible in the process of the system lags behind, be the smallest system overshoot. Controlled by two PID (PID is a variable in each group) control loop structure, known as the two sets of control loops: the main circuit and from the circuit, the main control loop from the loop output as the settings.

LNEYA - Model SUNDI -10℃~200℃ - Reactor Temperature Control System

The system with feedforward with PV, the master PID loop operation results of the PV output and feedforward signals as the composite of the settings from the control loop, through such control of the temperature gradient, to ensure the accuracy of temperature control system.

LNEYA - Model SUNDI -25℃ ~ 200℃ - Industrial Chiller Systems

Use high temperature resistant low-temperature magnetic drive pump or a leak-free high and low-temperature shield-driven pump, reduce the risk of system leakage. At the same time, the system has the advantages of low noise and big traffic flow.