Pres Block S.P.A. products
Plumbing-
Plastic Modular Manifold
Performances: Fluids accepted: water, glycol solutions, % glycol max: 50%, Working temperature: 5÷55 °C, Max temperature: 90 °C at 3 bar, Working pressure: 0÷6 bar, Max pressure: 10 bar, Burst pressure: > 22 bar at room temperature > 15 bar at 50 °C.
Ultra Block Manifold
Fluids accepted: water, glycol solutions, % glycol max: 50%, Working temperature: 5÷60 °C, Max temperature: 90 °C at 3 bar, Working pressure: 0÷6 bar, Max pressure: 10 bar, Burst pressure: > 15 bar at room temperature, Max torque to adjust F2” inlet: 100 N m, Kv flow coefficient when fully open: 8000 l/h.
Model RTCATM1/2-3/4 - Fill/Drain System
Performances: Fluids accepted: Water, Glycol solution, % glicol max: 50%, Pressure max: 10 bar, Temperature max: 90 °C, Working temperature: 50 °C, Max torque to apply to lock the system to the manifold: 10 kg cm, Condition of life test: Acqua a 4 bar e 80 °C per 3.000 ore, Plastic raw material: Nylon 66 Fv 30%, O’ring raw material: EPDM PEROSSIDICO 70 shore, Spring raw material: AISI 302.
Model 2,6 l/min and P/N ITRGMD026FLM - Standard Flow-Meters
Performances: Fluids accepted: water, glycol solutions, % glycol max: 50%, Working temperature: 5÷55 °C, Max temperature: 90 °C at 3 bar, Working pressure: 0÷6 bar, Max pressure: 10 bar, Burst pressure: > 22 bar at room temperature > 15 bar at 50 °C, Flow-rate range: 0÷2,6 l/min, Deviation percentage: + 15%, Max torque to adjust the flow-rate: 1 N-m (please use the proper adjusting key), Torque to lock the flowmeter to the manifold: Max 5 N-m, Suggested glue to lock the flowmeter: Loctite 5331.