Secutron
10 products found

Secutron products

Addressable Fire Alarm Systems

Secutron - Model MMX Series - Network Fire Detection & Alarm Control Unit

Secutron`s MMX Series Network Fire Alarm Control Units offer modular components to meet a wide variety of applications. Designed for peer-to-peer network communications, the MMX Series allows for a maximum of 63 nodes, while providing reliability, flexibility and expandability. The MMX Series is a powerful system capabale of providing network control, multi-channel voice evacuation and two-way fire fighter communications over a single pair of wires or fiber-optic cable. Each base unit consists of one intelligent signaling line circuit (SLC) capable of supporting 99 analog sensors and 99 addressable modules.

Secutron - Model MR-2200 Series - Intelligent Fire Alarm Control Unit

Secutron’s MR-2200 Intelligent input fire alarm control panels provide flexible and cost effective operation to satisfy system requirements for both economy and capability.

Secutron - Model MR-3500 Series - Powerful Intelligent Fire / Agent Release Control Units

Secutron’s MR-3500 Series systems are powerful intelligent fire / agent release control panels that are UL/ULC listed and FM Approved.

Conventional Fire Alarms Systems

Secutron - Model MR-2312-DDR - Twelve Zone Conventional Fire Alarm Control Panel

The MR-2312-LDR is equipped with twelve Class “B” (Style “B”) initiating circuits and four Class “B” (Style “Y”) indicating circuits rated @ 1.7 Amps maximum. (Total of 5 Amps). Two MR-2300-A Six Initiating Circuit Class “A” Converter Modules may be used for Class “A” (Style “D”) wiring of the initiating circuits. One MR-2300- NC4 Four Indicating Circuit Class “A” Converter Module may be used for Class “A” (Style “Z”) wiring of the indicating circuits. The MR-2312-LDR is configurable by the keypad (using the CFG-300 Configuration Tool) for onsite programming or by a PC for both onsite and remote programming. The MR-2312-LDR has a built-in UDACT/Digital Communicator and the cabinet will support up to 12 AH batteries. The panel can be semi-flush mounted with the optional MR-2312-FT trim ring.

Conventional Devices - Heat Detectors

Secutron - Model MHD-65-135 - Mircom Series 65 Plug in Heat Detector 135 Degrees

These 135 degree fixed and rate-of-rise heat detectors operate by using a matched pair of thermistors to sense heat.

Secutron - Model MHD-65-200 - Heat Detector

The heat detector operates by using a matched pair of thermistors to sense heat. One thermistor is exposed to the ambient temperature, the other is sealed. In normal conditions the two thermistors register similar temperatures; but, on the development of a fire, the temperature recorded by the exposed thermistor will increase rapidly, resulting in an imbalance that causes the detector to change into the alarm state.

Conventional Devices - Smoke Detectors

Secutron - Model BEAM1224 - Conventional Beam Smoke Detectors

The BEAM1224– CONVENTIONAL BEAM SMOKE DETECTORS is a four-wire conventional reflected beam smoke detector, which is uniquely suited for protecting open areas with high ceilings, where other methods of smoke detection are difficult to install and maintain. This type of conventional smoke detectors is to be used with UL Listed compatible control panels only. An advantage of this single-ended reflective design is that it is much easier to install than the dual-ended projected beam detectors.

Secutron - Model SD-2 / SD-4 Series - Conventional Smoke Detectors

The SD-2 / SD-4 Series photoelectric smoke detectors are engineered to meet strict UL fire safety codes and effectively respond to a wide spectrum of fires.

Secutron - Model MPD-65P Mircom Series - 65 Two-Wire Photoelectric Plug in Smoke Detector

The chamber is designed to exclude light from any external source. At an angle to the LED is a photo-diode which normally does not register the column of light emitted by the LED. In the event of smoke from a fire entering the chamber, the light pulse from the LED will be refracted into and registered by the photo-diode. If the photo-diode “sees” smoke on the two following pulses (alarm confirmation), the detector changes into the alarm state. A highly visible external clear LED fl ashes red when the detector is in operational standby and changes to steady red in alarm state. The clear LED allows for easy floor level detector type identification.

Addressable Devices & Detectors - 4000 Series Devices

Secutron - Model MIX-4001/MIX-4002 - Detector Bases

The NEW MIX-4001 and MIX-4002 mounting bases are used to interface series 4000 detectors to the SLC line and remote devices.