ATI Airtest Technologies, Inc.
- Home
- Companies & Suppliers
- ATI Airtest Technologies, Inc.
- Downloads
- ATI - K30 - CO2 Engine Module - ...
ATI - K30 - CO2 Engine Module - Brochure
AirTestAirTest Confidential11AirTest K30 C02 EngineProduct OverviewPage 1 of 3 EM_CO2-Engine_K30-STA_description_Rev1.02.doc Page 4 of 12 General PCB overview Figure 2 . COCOCOCO2EngineEngineEngineEngine™ K30K30K30K30 I/O notations, terminal positions and some important dimensions for mounting the K30 platform PCB into a host system (Top view). The blue filled pins are defined by default. Figure 3 . COCOCOCO2EngineEngineEngineEngine™ K30K30K30K30 OBA position. test/sample gas ports 11AirTest K30 C02 Engine Page 2 of 3 EM_CO2-Engine_K30-STA_description_Rev1.02.doc Page 11 of 12 COCOCOCO2EngineEngineEngineEngine™ K30K30K30K30----STASTASTASTA - Technical specification General Performance: Storage Temperature Range ................-30 to +70 °C Sensor Life Expectancy ........................> 15 years Maintenance Interval ............................no maintenance required 1 Self-Diagnostics ...................................complete function check of the sensor module Warm-up Time .....................................= 1 min Conformance with the standards ...........Emission: EN61000-6-3:2001 Immunity: EN61000-6-2:2001 RoHS directive 2002/95/EG Operating Temperature Range ............0 to 50 °C Operating Humidity Range ...................0 to 95% RH (non-condensing) Operating Environment ........................Residential, commercial, industrial spaces and Potentially dusty air ducts used in HVAC (Heating Ventilation and Air-Conditioning) systems.4 Electrical / Mechanical: Power Input...........................................4,5-14 VDC, stabilized to within 10% (external protection circuits required) 3 Current Consumption ............................40 mA average < 150 mA peak current (averaged during IR lamp ON, 120 msec) < 300 mA peak power (during IR lamp start-up, the first 50 msec) Electrical Connections4 ........................terminals not mounted (G+, G0, OUT1, OUT2, Din1, Din2, Status, TxD, RxD) Dimensions ........................................5,1 x 5,7 x 1,4 cm (Length x Width x approximate Height) CO2 Measurement: 4 Sensing Method ....................................non-dispersive infrared (NDIR) waveguide technology with ABC automatic background calibration algorithm Sampling Method ..................................diffusion Response Time (T1/e) ...........................20 sec diffusion time Measurement Range ............................0 - 5 000 ppmvol. Sensitivity..............................................± 20 ppm ± 1 % of measured value Accuracy 1.............................................± 30 ppm ± 5 % of measured value Pressure Dependence...........................+ 1.6 % reading per kPa deviation from normal pressure, 100 kPa On-board calibration support .................Din1 switch input to trigger Background Calibration @ 400 ppm CO2 Din2 switch input to trigger Zero Calibration @ 0 ppm CO2 Linear Signal Outputs: 4,5 D/A Conversion Accuracy......................± 2 % of reading ± 20 mV OUT1 D/A Resolution.........................10 mV Linear Conversion Range ........0 - 4 VDC for 0 - 2 000 ppmvol. Electrical Characteristics...........ROUT < 100 ?, RLOAD > 5 k? , Power input > 4,5 V 6 OUT2 D/A Resolution.........................5 mV Linear Conversion Range ........1 - 5 VDC for 0 - 2 000 ppmvol. Electrical Characteristics...........ROUT < 100 ?, RLOAD > 5 k? , Power input > 5,5 V 6 Digital Outputs: 4 Electrical Characteristics High Output level in the range 2.3V min to DVDD = 3.3V. (1 mA source) ............................. Low output level 0.75V max (4 mA sink). Protection 56R resistor in series. Function .................................. High level at CO2 High OUT3, CO2 High Alarm /Reset Level ... 800/700 ppm OUT4, CO2 High Alarm /Reset Level ... 1000/900 ppm UART Serial com port 4 Protocol ...............................................MODBUS open protocol, refer specification and registers definitions Hardware interface ...............................CMOS UART with RxD, TxD Baud Rate ......9600 Note 1: In normal IAQ applications. Accuracy is defined after minimum 3 weeks of continuous operation. However, some industrial applications do require maintenance. Please, contact SenseAir for further information Note 2: SO2 enriched environments are excluded. Note 3: Notice that absolute maximum rating is 14V, so that sensor can be used with 12V+-10% supply Note 4: Different options exist and can be customized depending on the application. Please, contact SenseAir for further information Note 5: During power up, OUT1 and OUT2 are defined to be low. Exact value depends on many factors including temperature. Note 6: For the buffered outputs OUT1 and OUT2 the maximum output voltage range equals power voltage input minus 0,5 V AirTest11AirTest K30 C02 Engine Page 3 of 3
Most popular related searches
