Biochrom - a division of Harvard Bioscience

Biochrom Libra - S80 - Double Beam Spectrophotometer Brochure

High performance instruments with added application value for academia, research and industryBiochrom LibraUV-Visible SpectrophotometersNew Double BeamSpectrophotometers Biochrom Libra – Real Choice in SpectrophotometryBiochrom are experts in spectrophotometry andhave manufactured quality scientific instrumentsfor forty years. Our spectrophotometry ranges include not onlyBiochrom Libra spectrophotometers but alsoBiochrom WPA spectrophotometers andcolorimeters for education and life sciences.As LKB Biochrom we launched the now famousUltrospec® range in 1982 followed by theGeneQuant® range of spectrophotometers. Our name may not be familiar but our instrumentsare found in hospitals, universities and industriallaboratories worldwide. We supply ourinstruments through a global network ofindependent distributors and also manufacture forsome of the world’s finest scientific companies.All Biochrom instruments are CE marked and aremanufactured under a rigorous quality system.Biochrom Libra - why compromise?The Biochrom Libra range is about freedom to workthe way you want to. Don’t settle for anything lessthan your perfect solution. From academia toindustry, Biochrom has the spectrophotometer to suityour particular application needs - without requiringyou to compromise on performance or overspend.The Biochrom Libra range of UV/Visiblespectrophotometers extends from the practical, splitbeam laboratory workhorse, to high performance,variable bandwidth, double beam systems ideal forthe highly regulated pharmaceutical environment.With common hardware and software platforms, allBiochrom Libra instruments provide flexible, robust,reliable measurements and are easy to use and afford.Our new instruments are designed to be flexible witha choice of software and a range of interchangeableaccessories that are easy to install. Select theconfiguration that fits your needs and don’t pay forunnecessary features that you won’t use.Many sample measurements taken on aspectrophotometer are straightforwardand benefit from the speed and ease-of-use offered by a stand-alone instrument.The wide ranging applications foundwithin today’s laboratories call forflexibility. Now Biochrom Libra instrumentsdeliver high function applicationcapabilities in a stand-alone instrument. By incorporating the latest technology andcustom written, application-led software,Biochrom Libra spectrophotometers havethe advanced features to meet yourlaboratory’s needs, bringing you thebenefits of both flexibility and walk-upefficiency without compromise.All stand-alone instruments offer:? Colour touchscreen displayFull control of all instrumentparametersOverlay of multiple wavelengthscans and kinetic curvesPost run manipulation of data? USB interfaces for data storageand exportInterface for USB memory sticknext to the display allows storageof methods and data in secureand ASCII formatsInterface for USB cableconnection to PC? Full suite of software applicationsprovided as standardSingle wavelength measurementin Absorbance, % Transmissionand concentration measurementsusing factorsWavelength scanning Calibration curvesKineticsPre-stored Life ScienceapplicationsTrace Manager for manipulationof data stored on the instrumentor USB memory stick? Software security featuresMethod storage including allinstrument and accessoryparameters with passwordprotectionMulti-level user login? Multiple language options? Equation EditorTurn your instrument into a “customapplication analyzer” by setting up storedmethods including calculations based onmeasured sample data, for example:Absorbance difference and ratios.Application examples include: olive oiland chlorophyll analysis and toluene inhexane resolution check.? Choice of data export methodsAll stand-alone Biochrom Librainstruments offer users a choice in exportand print functionality with selectionparameters stored as part of any methodExport to PC via USB cable(standard)Built in printer (optional)Export to a PC via Bluetooth®(optional)Stand-Alone InstrumentsPC ControlModules Resolution Resolution Resolution ResolutionLite Life Science CFRQuick Read and Quick ? ? ? ?ScanWavelength Scanning, Kinetics, ? ? ?Quantitative Calibration Curves Validation ? ? ? ?Method ? ? ?DeveloperLife Science ? ?Methods21 CFR ?Part 11ComplianceAccessory Control? ? ?For many users having an external PC tocontrol their spectrophotometer andmanipulate data gives them the ultimate inflexibility and control. Whether looking forsmall differences in multiple spectraloverlays, carrying out post-run manipulationson large numbers of samples or simplyfulfilling regulatory requirements, Biochrom’sResolution software has the flexibility towork in the way you want.Resolution software is supplied in differentmodules to meet the applicationrequirements of different customer groupsand offers a simple upgrade path shouldyour requirements change.Choose:? Resolution Lite for Quick Read and fastscanning only? Resolution for all routine measurements? Resolution Life Science for nucleicacids, proteins and cell densitymeasurements? Resolution CFR if you need full 21 CFRpart 11 complianceOffering the familiar look and feel ofMicrosoft® Office 2007, Resolution softwareis compatible with Windows® XP, WindowsVista and Windows 7 operating systems.Data export options include Microsoft Wordand Excel® plus Adobe® PDF formats.European Pharmacopoeia(EP) ComplianceCustomers manufacturingpharmaceutical products incompliance with the EP look for aUV/Visible spectrophotometer thatmeets the specifications defined in EP 2.2.25. This publishesspecifications for the control ofwavelength, Absorbance, stray light,resolution and spectral slit width.The specification for resolution states“When prescribed in a monograph,measure the resolution of theapparatus as follows: record thespectrum of a 0.02 % V/V solution oftoluene R in hexane R. The minimumratio of the absorbance at themaximum at 269 nm to that at theminimum at 266 nm is stated in themonograph.” EP version 6.8 includesseven product monographs thatprescribe this ratio.To claim full compliance aninstrument should give a ratiogreater than 2.0.The Libra S70 with its fixed 1nmbandwidth and the S80 with itsvariable bandwidth both achieve this specification.With a large sample compartment theinstrument can be configured with quickchange accessories including sipper,temperature control accessories, longpathlength, test tube, and film holders.For the complete range of accessoriesplease see our website.Accessorieswww.biochrom.co.uk/select-a-spectrophotometer/This website tool helps you to find the ideal Biochrom spectrophotometerBiochrom Libra Software Functionality ComparisonSoftware Stand-Alone Resolution Resolution Resolution ResolutionModules Instrument Lite Life CFRSoftware ScienceSingle Wavelength MeasurementWavelengthScanningConcentrationStandard CurveKineticsValidationLife ScienceMethodsCustom MethodDevelopment21 CFR Part 11ComplianceQuantitation usingcalibration curveswith multiplestandards and achoice of curve fitsSample overlays, automatic featuredetection and post run datamanipulationSample overlays, automatic feature detection andpost run data manipulation, spectral scans andspectral arithmetic manipulationsSingle or multiple wavelength measurements in Absorbance, % Transmission or concentrationincluding full instrument control, batch processing of sample data and calculations on collected dataGeneration of calibration curves includingfull instrument and accessory control, choice of line fit, QC limit testing and statistical analysisof sample dataSerial (or parallelmeasurements withthe optional cellchanger) includingsample overlaysand post run datamanipulationAbsorbance versus time measurements onsingle or multiple cells (with optional cell changer),multiple sample overlays, batch processing ofsample data and post run sample calculationsand manipulationsDNA, RNA & Oligoconcentration andpurity measurementwith optionalwavelengthscanning.CyDyeTM DNAquantitation.Tm calculation.Proteinconcentration bydirect UVmeasurement orBradford, Biuret,Lowry or BCAcolorimetricmethodsEquation Editorallows the set up of storedmethods that caninclude calculations basedon measuredsample data e.g.Absorbance ratioand difference.Ability to set updifferent users as part of defined groups.Audit trail.ElectronicsignatureSoftware module that allows users to enterand store full details of their Certified Reference Materials(CRMs) and schedule tests to be carriedout at defined intervals to meet their Standard Operating Procedures. Users are prompted to insert the specifiedCRM at the scheduled time and the system automatically checks theperformance against the instrument specification.DNA, RNA & Oligo concentration& purity measurementProtein quantitation via direct UVmethods or BCA, Buiret, Bradford,Lowry & Colloidal Gold methodsCell Density measurementThe Method Developer module allowscustom methods to be set up in all applications.These can include sample prompts containinginformation such as method SOP timings and theability to lock individual method parametersFixed wavelength, Abs/%T,Concentration (factor)Application SectorsQUALITY CONTROL“Our profitability relies on preciseanalytical data. To keep productionrunning at optimal efficiency we needhigh throughput measurements andresults must be entirely dependableacross the long term” Manufacturingquality control (QC) manager.TAKE A LOOK AT THE BIOCHROMLIBRA S70? Fully European Pharmacopoeiacompliant system? Password login to protect methods? High performance system withnarrow bandwidth for precise analysis(toluene hexane ratio of >2.0)? Optional validation logbook forIQ/OQ/PQThe Biochrom Libra S70 is an affordable,high specification instrument with a 1 nmbandwidth intended for busy, multi-useranalysis in pharmaceutical, QC, analyticaland research laboratories. Forlaboratories requiring high performanceand 21 CFR compliance consider addingResolution CFR module.MULTI-USER LABORATORIES“We need a flexible system that scientistscan walk up to and use for theirindividual projects. It needs to be easy touse, hardworking and robust, but havethe flexibility to cover the whole range of applications” Academic PhDsupervisor.TAKE A LOOK AT THE BIOCHROMLIBRA S50 OR S60? Long life Xenon lamp technology forlow cost of ownership? All application software is built in - noextra modules to buy? Multi-user analytical instrument withsecure login? Custom calculation facility usingEquation Editor? Large sample compartment makingchanging accessories easy ? Built in Life Science methodsincluding nucleic acid concentrationand purityThe Biochrom Libra S50 and S60 modelsare robustly designed to deliver reliable,low maintenance UV/Visiblespectrophotometry in environments withmultiple users. Users can quickly andeasily walk up to the instrument, set up asample, select the appropriatemeasurement protocols and collect theresults. The convenient USB port enablesindividual users to load personal methodsand transport data. Good LaboratoryPractice (GLP) performance qualificationacross multiple user accounts is facilitatedvia a different security level access. The Biochrom Libra S60 offers theadditional flexibility and familiarity of adouble beam optical design. For moreadvanced data manipulation featuresconsider adding Resolution software.RESEARCH/METHOD DEVELOPMENT“We develop methods for our factoriesworldwide so we need a highperformance system and worldwideregulatory compliance with full traceabilityis an absolute must. However we can’tpredict the future, so we need theflexibility to handle all UV-Vis applications”Pharmaceutical method developmentscientist.TAKE A LOOK AT THE BIOCHROMLIBRA S80PC UPGRADED WITHRESOLUTION CFR? High performance variable bandwidthUV-Visible spectrophotometer? Full European Pharmacopoeiacompliance ? 21 CFR part 11 compliance usingResolution CFR ? Custom calculation facility formethod development in theResolution Software? Wide range of accessories that areeasily changedBiochrom’s new ‘top of the range’ high performance instrument. The Biochrom Libra S80 gives consistentresults of the highest quality. Satisfying allrequirements for EuropeanPharmacopoeia (EP) and optional systemqualification. The Biochrom Libra S80delivers Biochrom’s ultimate resolutionand precision.For a full list of accessories and technical specifications for all instrumentssee www.biochrom.co.ukBiochrom Libra Options and Order CodesS50 S50PC S60 S60PC S70 S70PC S80 S80PCS50 S50PC S60 S60PC S70 S70PC S80 S80PCBeamConfigurationLampWavelength RangeBandwidthDetectorPhotometricRangeColour TouchScreenBuilt in SoftwareResolution PCControl SoftwareUSB StorageAccessoriesBuilt in ThermalPrinterMethod StorageCE MarkEP ComplianceIQ/OQ/PQLanguagesCell CompatibilityPowerRequirementWeightDimensions(WxDxH)Instrument onlyWith ThermalPrinterWith Bluetooth®With ThermalPrinter andBluetooth®Split beam(with reference beamcompensation)190-1100nm2nm 1nm Variable (0.5,1,2,4nm)Double BeamXenon Deuterium/TungstenDual Solid State Silicon photodiode-4.000A to 4.000A? ? ? ?? ? ? ?Optional Standard Optional Standard Standard Standard Standard Standard ???? ? ? ? ? ? ? ? ?Optional Optional Optional OptionalUp to 90 Up to 90 Up to 90 Up to 90on-board, Unlimited on-board, Unlimited on-board, Unlimited on-board, Unlimitedunlimited on PC unlimited on PC unlimited on PC unlimited on PCvia USB via USB via USB via USB ? ? ? ? ? ? ? ? ? ? ? ?Optional Optional Optional Optional Optional Optional Optional OptionalEnglishEnglishEnglishEnglishEnglishEnglishEnglishEnglishFrench French French FrenchGerman German German GermanSpanish Spanish Spanish SpanishCuvette, Microcell*, 1-100mm Pathlength Cell*, Test Tube*, Film*100-240V AC, 50/60Hz, 150VA17kg (37.5lb)54 x 46 x 32cm (21.3 x 18.1 x 12.6 inches)80-7000-01 80-7000-00 80-7000-11 80-7000-10 80-7000-21 80-7000-20 80-7000-31 80-7000-3080-7000-02 80-7000-12 80-7000-22 80-7000-32 80-7000-03 80-7000-13 80-7000-23 80-7000-3380-7000-04 80-7000-14 80-7000-24 80-7000-34Order Codes* optional accessoriesMicrosoft, Windows and Excel are registered trademarks ofMicrosoft CorporationCyDye is a trademark of GE Healthcare CompaniesAdobe is a registered trademark of Adobe SystemsIncorporatedUltrospec and GeneQuant are registered trademarks ofBiochrom Ltd.Bluetooth is a registered trademark of the Bluetooth SIGBiochrom Ltd 22 Cambridge Science Park,Milton Road, Cambridge CB4 0FJ UKTel: +44 (0)1223 423723Fax: +44 (0)1223 420164Email: enquiries@biochrom.co.ukwww.biochrom.co.ukBiochrom US 84 October Hill Road,Holliston, MA 01746-1388 USATel: 877- BIO-CHROM (877-246-2476)(Toll free)Fax: 508-429-5732email: sales@biochrom-us.comwww.biochrom-US.comDistributors worldwide:80-7000-35 issue 1
Most popular related searches