VSI Electronics Pvt. Ltd.
- Home
- Companies & Suppliers
- VSI Electronics Pvt. Ltd.
- Downloads
- Catalog Kits -Water-Soil Analysis
Catalog Kits -Water-Soil Analysis
MICROPROCESSOR BASED WATER/SOIL ANALYSIS KIT (Model : 302) WITH 8 PARAMETERS *pH *ORP *COND. *TDS *SALINITY *D.O. *TURBIDITY *TEMPERATURE Microprocessor Based Water/Soil Analysis Kit (Model : VSI-302) TECHNICAL SPECIFICATIONS: pH MEASUREMENT Range : 0-14 pH Resolution : 0.01pH Accuracy : + 0.01 pH ( relative) Temp. Compensation : Automatic with Pt-100 Probe & Manual By Keys Buffer Recognition : 4.00, 7.00 & 9.20 ( Automatic) Calibration : Automatic & Manual : 2 Point, 3 Point (Programmable) DISSOLVED OXYGEN MEASUREMENT Range : 0 to 20 ppm Resolution : 0. 1 ppm Calibration : Automatic Accuracy : + 0.2 ppm + 1digit Temp. Compensation : Automatic with Pt-100 Probe & Manual By Keys Pressure Comp. : 0-999 mm of Hg ( Manual) Salinity Correction : 0-20 mg/l mV/ORP MEASUREMENT Range : - 1999 to +1999 mV Resolution : 1 mV Accuracy : + 0.1% + 1digit Calibration : Manual TEMPERATURE MEASUREMENT Range : -20.0 to +200 degree C Resolution : 0.1 degree C Accuracy : + 0.2% + 1digit Input : Pt100 Calibration : Manual CONDUCTIVITY MEASUREMENT Range : 0-1000 mS/cm Range Selection : Automatic Resolution : 0.01/ 0.1/ 1 uS/cm or mS/cm as per range No. of Ranges : Six Accuracy : + 0.5% Temp. Compensation : Automatic with Pt-100 Probe Ref. Temperature : 25oC/20 degree C (Programmable) Temp. Co-efficient : 0-4% adjustable Cell Constant : 0.05 to 2.0 adjustable TDS MEASUREMENT Range : 0-200ppt in 5-Ranges Automatic Resolution : 0.01/0.1/1 ppm or ppt as per Range Temp. Comp. : Automatic Accuracy : + 0.5% TDS Factor : 0.50 By Default (Adjustable) Cell Constant : 0.05 to 2.0 Adjustable Ref. Temperature : 25oC/20 degree C (Programmable) TURBIDITY MEASUREMENT Range : 0-1000 NTU in Two Ranges Resolution : 0.1 NTU in Lowest Range Range Selection : Automatic Accuracy : ± 3% FS ± 1 digit Detector : Photodiode/Photocell Sample System : 30 mm Clear Glass Test Tubes Light Source : 6V Tungsten Lamp Calibration : Manual SALINITY MEASUREMENT Range : 0-200ppt in 5-Ranges - Automatic Resolution : 0.01/0.1/1 ppm or ppt as per Range Temp. Compensation: Automatic Accuracy : + 0.5% Salinity Factor : 0.75 By Default( Adjustable) Cell Constant : 0.05 to 2.0 Adjustable Ref. Temperature : 25oC/20 degree C (Programmable) DATA INTERFACE RS232 & Parallel output available for interfacing to computer/printer. GENERAL SPECIFICATIONS Display : 16 Characters X 2 Lines Alpha Numeric BL LCD Display Format : Temp. and Parameter Simultaneously Real Time Display: 24 Hour Mode With Date & Time Controls : By Soft Keys Menu Driven Memory Storage : Up to 1000 samples Power Supply : 230 V + 10%, 50 Hz AC & Inbuilt 12V Rechargeable Battery Digital Output : Serial RS-232 : Parallel Centronics Print Format : All Data / Date Wise (Programmable) Error Indication : pH Error, ORP Error, T-Error STANDARD ACCESSORIES 1. Combined pH electrode 2. Buffer solutions 3. Conductivity/TDS/Salinity Cell 4. Temp. probe 5. DO probe, DO membranes, KCL 6. Operation manual 7. Test Tubes 8. Data Cable ADDITIONAL ACCESSORIES ON REQUEST 1. ORP Electrode AT EXTRA COST 2. Soil Probe AT EXTRA COST Appearance and specifications subject to change due to continuous development : PRINT FORMAT : FEATURES ? Measures 8 parameters - pH, mV/ORP, Conductivity, Salinity, D.O., Temperature, TDS and Turbidity ? Highly Accurate & Stable ? User Friendly & Menu Driven Software ? 16 x 2 Line Alphanumeric Backlit LCD Display ? Computer & Printer Attachment Facility ? Storage for 1000 Samples ? Mains Cum Battery Operated ? Rechargeable Battery The VSI make Portable Microprocessor Based Water/Soil Analysis Kit (VSI-302) is suitable for measurement of eight (8) parameters i.e. pH, ORP, Conductivity, Salinity, Dissolved Oxygen, Temperature, TDS and Turbidity of any solution. This Mains/Battery operated kit is housed in a rugged fibre glass briefcase with provision to keep all the accessories inside. A 12V Rechargeable Battery is provided within the kit that makes it extremely useful for field and laboratory use. The use of latest microcontroller technology makes it reliable, accurate, easy to operate and low power consuming instrument. RS-232 and Parallel output is available for interfacing to Computer/Printer. Manufactured By : VSI ELECTRONICS PVT. LTD., F-330, PHASE VIII-B, INDUSTRIAL FOCAL POINT, S.A.S. NAGAR, MOHALI – 160 071 (PUNJAB). TELEFAX : 0172-2227238 MOBILE : 0-9855076463, 9814016463, 9041931993 E-MAIL : vsielectronicsmohali@gmail.com WEBSITE : http://vsielectronics.webs.com DATE TIME TEMP(Deg.C) PARAMETER MODE SR.No 05/07/10 11:19 T= 020.0 pH= 07.00 MANUL 001 05/07/10 11:19 T= 020.0 mV= 0000 MANUL 002 05/07/10 11:19 T= 020.0 DO= 00.0 ppm MANUL 003 05/07/10 11:20 T= 020.0 C=00.00 us/cm MANUL 004 05/07/10 11:20 T= 020.0 TDS=00.00 ppm MANUL 005 05/07/10 11:20 T= 020.0 SAL=000.5 ppt MANUL 006 05/07/10 11:22 T= 020.0 TUR=400 ntu MANUL 007
Most popular related searches
