GrayWolf Sensing Solutions
- Home
- Companies & Suppliers
- GrayWolf Sensing Solutions
- Downloads
- Direct Sense RH ThermoHygrometer - ...
Direct Sense RH ThermoHygrometer - Features Brochure
GrayWolf
IAQ Surveyor II and
IAQ SurveyorPro
GRAYWOLF
FEATURES COMPARISON
Page 1 of 4
graywolf iaq monitors
GrayWolf DS
IAQ Kit
GrayWolf DS
IAQ Plus Kit
EASE OF USE
Instrument Uses MS Windows™ Operating System (along
with extremely intuitive WolfSense user interface)
YES YES NO
Extensive on-Screen Sensor Tips, Government and Industry
Guidelines, Application Background Info for each parameter
YES YES NO
On-Screen Help (Text, and even Video) Files YES YES NO
One-click access to Application Related Documents (.pdfs,
etc.)
YES YES NO
On-Screen Product Manual YES YES NO
DISPLAY
Maximum Parameters displayed simultaneously 15 15 6
Color Display YES YES NO
Backlit Display YES YES NO
Tactile Screen YES YES NO
DATALOGGING/ANNOTATION
Maximum number of Parameters monitored/logged
simultaneously
15 15 8
Descriptive (Microsoft folder\\subfolder\\location) data fi le nam-
ing format: “10 Main St\\ABC Co\\2nd Floor\\Childcare Room”
YES YES NO
All Sensors show 90%+ Response in <90 seconds YES YES YES
Text, Graphic, Audio, Digital Photo fi les link to data fi les YES YES NO
Microsoft Word™ Field Forms link to data fi les YES YES NO
Event Notes with Time Stamp link to data fi les YES YES NO
Custom Notes allows manual linking of any PDA fi le (Pocket
CAD, Word, GPS, etc.) to data fi les
YES YES NO
Instrument Stores and Displays Factory and User Calibration
History, linking it to each data fi le
YES YES NO
User-settable alarms for all parameters YES YES NO
Entire Log File may be reviewed without Interrupting Log Ses-
sion
YES YES NO
Min/Max/Average may be displayed while measuring or
logging
YES YES YES
Trend Logging AND Snapshot/Discrete Logging stores
averaged values (user selected averaging period, averaging
over full log interval, or instantaneous capture)
YES YES YES
Standard Memory (sets of readings) in Timed / Trend Log
Mode
1,000,000+ 1,000,000+ 7000
Standard Memory (sets of readings) in Snapshot (aka “sam-
ple”, “discrete”) Log Mode
1,000,000+ 1,000,000+ 7000
REPORTING
Data transfer software for Desktop PC YES YES YES
Simple export to MS Excel YES YES YES
Sophisticated graph generation: 3D Graphs, Multi-Y or Strip
Graphs, Balloon Graph Comments
YES YES YES
Event Notes and Alarm Lines synch to graphs YES YES YES
Bar Graph Comparisons of Parameters at varied locations YES YES YES
Desktop PC Software allows fi les (Photo, CAD, other
Monitor’s Data, etc.) to be associated after data has been
downloaded
YES YES YES
Advanced Report Generator Software produces professional,
automated reports, including photos/graphs/tables in minutes
OPTIONAL OPTIONAL OPTIONAL
Reporting Template allows Text, Drawing, Field Notes, Cal info
etc to auto incorporate
OPTIONAL OPTIONAL NO
Instrument can output data directly to a printer YES YES YES
PARAMETERS
Carbon Dioxide (CO2) 0-10,000ppm
Also µg/m3 for all gasses
0-10,000ppm
Also µg/m3 for all gasses
0-5,000ppm
VOC (Volatile Organic Chemicals-ppb or ppm sensitivity) YES OPTIONAL NO
Carbon Monoxide (CO) YES YES YES
Air temperature with IAQ probe -10 to 70ºC -10 to 70ºC -10 to 70ºC
Relative Humidity 0-100% 0-100% 0-100%
Dewpoint Temperature YES YES YES
Wetbulb Temperature YES YES NO
Absolute Humidity YES YES NO
Humidity Ratio YES YES NO
Specifi c Humidity YES YES NO
Telescoping Hotwire Airspeed OPTIONAL
0-6000 fpm
OPTIONAL
0-6000 fpm
OPTIONAL
0-2500 fpm
Articulating Tip Hotwire Airspeed OPTIONAL OPTIONAL NO
Pitot Tube Airspeed NO* NO* OPTIONAL
(PRO version only)
Basic Volume Flow (CFM, l/s, m3/sec) YES YES YES
Differential Air Pressure NO* NO* YES
(PRO version only)
Surface, Immersion, Air/Gas Temperature NO* NO* OPTIONAL
(PRO version only)
Duct Volume Airfl ow Calculation OPTIONAL OPTIONAL NO
Fumehood Face Velocity Calculation OPTIONAL OPTIONAL NO
% Outdoor Air Ventilation Calculation OPTIONAL OPTIONAL NO
GrayWolf
IAQ Surveyor II and
IAQ SurveyorPro
GrayWolf DS
IAQ Kit
GRAYWOLF
FEATURES COMPARISON
Page 2 of 4
GrayWolf iaq monitors
*By interfacing a GrayWolf Zephyr via serial card to the Mobile PC, this is actually possible.
GrayWolf DS
IAQ Plus Kit
Outdoor Air Ventilation Rate (per person or per area)
Calculation
OPTIONAL OPTIONAL NO
3-Function Probe (Air Velocity, %RH, Temperature) NO NO OPTIONAL
Ozone (O3) OPTIONAL OPTIONAL NO
Ammonia (NH3) OPTIONAL OPTIONAL NO
Sulfur Dioxide (SO2) OPTIONAL OPTIONAL NO
Nitrogen Dioxide (NO2) OPTIONAL OPTIONAL NO
Nitric Oxide (NO) OPTIONAL OPTIONAL NO
Hydrogen Sulfi de (H2S) OPTIONAL OPTIONAL NO
Hydrogen Cyanide (HCN) OPTIONAL OPTIONAL NO
Hydrogen Chloride (HCl) OPTIONAL OPTIONAL NO
Chlorine (Cl2) OPTIONAL OPTIONAL NO
Ethylene Oxide (CH2CH2O) OPTIONAL OPTIONAL NO
Oxygen (O2) OPTIONAL OPTIONAL NO
Hydrogen (H2) OPTIONAL OPTIONAL NO
Hydrogen Fluoride (HF) OPTIONAL OPTIONAL NO
Chlorine Dioxide (ClO2) OPTIONAL OPTIONAL NO
Phosgene (COCl2) OPTIONAL OPTIONAL NO
Phosphine (PH3) OPTIONAL OPTIONAL NO
Silane (SiH4) OPTIONAL OPTIONAL NO
Arsine (AsH3) OPTIONAL OPTIONAL NO
Diborane (B2H6) OPTIONAL OPTIONAL NO
Fluorine (F) OPTIONAL OPTIONAL NO
Particle Counts OPTIONAL OPTIONAL NO
Particulate Concentration (mg/m3) OPTIONAL OPTIONAL NO
INSTRUMENTATION
Keyboard YES* YES* YES
Handwriting Recognition YES YES NO
Built-in Voice Recorder YES YES NO
Compact Flash Card Slot YES YES NO
Secure Digital Card Slot YES YES NO
Battery Life 14 hours** 14 hours** 130 hours
Instrument Comes With Pocket Word, Excel, Contacts, Tasks,
Calculator and other Microsoft Applications
YES YES NO
ACCESSORIES
Hands-Free Operational Soft Case and Probe Pouch YES YES NO
GrayWolf
IAQ Surveyor II and
IAQ SurveyorPro
GrayWolf DS
IAQ Kit
GRAYWOLF
FEATURES COMPARISON
Page 3 of 4
graywolf iaq monitors
*Virtual keyboard included. Optional folding or roll-up, full-sized keyboards
**Mobile PC with backlight off. Not including probe battery life (typically 120+ hours)
(probe may be worn
behind to minimize
breathing on
sensors)
GrayWolf DS
IAQ Plus Kit
(probe may be worn
behind to minimize
breathing on
sensors)
Hard shell Security Case secures instrument and probe
during fi eld use and can be used as a shippable
enclosure
YES
(unit is truly designed for
both semi-permanent and
walk-thru surveys)
YES
(unit is truly designed for
both semi-permanent and
walk-thru surveys)
NO
(yet not so small that
it is easily “pocketed”)
Extended Life Batteries OPTIONAL OPTIONAL NO
2 ½ inch Belt IR printer OPTIONAL OPTIONAL NO
8 ½ inch serial printer OPTIONAL OPTIONAL OPTIONAL
8 ½ inch Bluetooth wireless printer OPTIONAL OPTIONAL NO
Full-sized Bluetooth Fabric or Folding Keyboard OPTIONAL OPTIONAL NO
Portable Air Pump to draw samples across sensors OPTIONAL OPTIONAL OPTIONAL
User Gas Calibration Kit OPTIONAL OPTIONAL OPTIONAL
User %RH Calibration Kit OPTIONAL OPTIONAL OPTIONAL
Barcode Wand OPTIONAL OPTIONAL NO
GPS Kit OPTIONAL OPTIONAL NO
3rd Party HVAC, IH, FM & other application software OPTIONAL OPTIONAL NO
GrayWolf DS
IAQ Kit
GRAYWOLF
FEATURES COMPARISON
Page 4 of 4
graywolf iaq meters GrayWolf DS
IAQ Plus Kit
GrayWolf
IAQ Surveyor II and
IAQ SurveyorPro
Most popular related searches