GrayWolf Sensing Solutions

Direct Sense RH ThermoHygrometer - Features Brochure

GrayWolf IAQ Surveyor II and IAQ SurveyorPro GRAYWOLF FEATURES COMPARISON Page 1 of 4 graywolf iaq monitors GrayWolf DS IAQ Kit GrayWolf DS IAQ Plus Kit EASE OF USE Instrument Uses MS Windows™ Operating System (along with extremely intuitive WolfSense user interface) YES YES NO Extensive on-Screen Sensor Tips, Government and Industry Guidelines, Application Background Info for each parameter YES YES NO On-Screen Help (Text, and even Video) Files YES YES NO One-click access to Application Related Documents (.pdfs, etc.) YES YES NO On-Screen Product Manual YES YES NO DISPLAY Maximum Parameters displayed simultaneously 15 15 6 Color Display YES YES NO Backlit Display YES YES NO Tactile Screen YES YES NO DATALOGGING/ANNOTATION Maximum number of Parameters monitored/logged simultaneously 15 15 8 Descriptive (Microsoft folder\\subfolder\\location) data fi le nam- ing format: “10 Main St\\ABC Co\\2nd Floor\\Childcare Room” YES YES NO All Sensors show 90%+ Response in <90 seconds YES YES YES Text, Graphic, Audio, Digital Photo fi les link to data fi les YES YES NO Microsoft Word™ Field Forms link to data fi les YES YES NO Event Notes with Time Stamp link to data fi les YES YES NO Custom Notes allows manual linking of any PDA fi le (Pocket CAD, Word, GPS, etc.) to data fi les YES YES NO Instrument Stores and Displays Factory and User Calibration History, linking it to each data fi le YES YES NO User-settable alarms for all parameters YES YES NO Entire Log File may be reviewed without Interrupting Log Ses- sion YES YES NO Min/Max/Average may be displayed while measuring or logging YES YES YES Trend Logging AND Snapshot/Discrete Logging stores averaged values (user selected averaging period, averaging over full log interval, or instantaneous capture) YES YES YES Standard Memory (sets of readings) in Timed / Trend Log Mode 1,000,000+ 1,000,000+ 7000 Standard Memory (sets of readings) in Snapshot (aka “sam- ple”, “discrete”) Log Mode 1,000,000+ 1,000,000+ 7000 REPORTING Data transfer software for Desktop PC YES YES YES Simple export to MS Excel YES YES YES Sophisticated graph generation: 3D Graphs, Multi-Y or Strip Graphs, Balloon Graph Comments YES YES YES Event Notes and Alarm Lines synch to graphs YES YES YES Bar Graph Comparisons of Parameters at varied locations YES YES YES Desktop PC Software allows fi les (Photo, CAD, other Monitor’s Data, etc.) to be associated after data has been downloaded YES YES YES Advanced Report Generator Software produces professional, automated reports, including photos/graphs/tables in minutes OPTIONAL OPTIONAL OPTIONAL Reporting Template allows Text, Drawing, Field Notes, Cal info etc to auto incorporate OPTIONAL OPTIONAL NO Instrument can output data directly to a printer YES YES YES PARAMETERS Carbon Dioxide (CO2) 0-10,000ppm Also µg/m3 for all gasses 0-10,000ppm Also µg/m3 for all gasses 0-5,000ppm VOC (Volatile Organic Chemicals-ppb or ppm sensitivity) YES OPTIONAL NO Carbon Monoxide (CO) YES YES YES Air temperature with IAQ probe -10 to 70ºC -10 to 70ºC -10 to 70ºC Relative Humidity 0-100% 0-100% 0-100% Dewpoint Temperature YES YES YES Wetbulb Temperature YES YES NO Absolute Humidity YES YES NO Humidity Ratio YES YES NO Specifi c Humidity YES YES NO Telescoping Hotwire Airspeed OPTIONAL 0-6000 fpm OPTIONAL 0-6000 fpm OPTIONAL 0-2500 fpm Articulating Tip Hotwire Airspeed OPTIONAL OPTIONAL NO Pitot Tube Airspeed NO* NO* OPTIONAL (PRO version only) Basic Volume Flow (CFM, l/s, m3/sec) YES YES YES Differential Air Pressure NO* NO* YES (PRO version only) Surface, Immersion, Air/Gas Temperature NO* NO* OPTIONAL (PRO version only) Duct Volume Airfl ow Calculation OPTIONAL OPTIONAL NO Fumehood Face Velocity Calculation OPTIONAL OPTIONAL NO % Outdoor Air Ventilation Calculation OPTIONAL OPTIONAL NO GrayWolf IAQ Surveyor II and IAQ SurveyorPro GrayWolf DS IAQ Kit GRAYWOLF FEATURES COMPARISON Page 2 of 4 GrayWolf iaq monitors *By interfacing a GrayWolf Zephyr via serial card to the Mobile PC, this is actually possible. GrayWolf DS IAQ Plus Kit Outdoor Air Ventilation Rate (per person or per area) Calculation OPTIONAL OPTIONAL NO 3-Function Probe (Air Velocity, %RH, Temperature) NO NO OPTIONAL Ozone (O3) OPTIONAL OPTIONAL NO Ammonia (NH3) OPTIONAL OPTIONAL NO Sulfur Dioxide (SO2) OPTIONAL OPTIONAL NO Nitrogen Dioxide (NO2) OPTIONAL OPTIONAL NO Nitric Oxide (NO) OPTIONAL OPTIONAL NO Hydrogen Sulfi de (H2S) OPTIONAL OPTIONAL NO Hydrogen Cyanide (HCN) OPTIONAL OPTIONAL NO Hydrogen Chloride (HCl) OPTIONAL OPTIONAL NO Chlorine (Cl2) OPTIONAL OPTIONAL NO Ethylene Oxide (CH2CH2O) OPTIONAL OPTIONAL NO Oxygen (O2) OPTIONAL OPTIONAL NO Hydrogen (H2) OPTIONAL OPTIONAL NO Hydrogen Fluoride (HF) OPTIONAL OPTIONAL NO Chlorine Dioxide (ClO2) OPTIONAL OPTIONAL NO Phosgene (COCl2) OPTIONAL OPTIONAL NO Phosphine (PH3) OPTIONAL OPTIONAL NO Silane (SiH4) OPTIONAL OPTIONAL NO Arsine (AsH3) OPTIONAL OPTIONAL NO Diborane (B2H6) OPTIONAL OPTIONAL NO Fluorine (F) OPTIONAL OPTIONAL NO Particle Counts OPTIONAL OPTIONAL NO Particulate Concentration (mg/m3) OPTIONAL OPTIONAL NO INSTRUMENTATION Keyboard YES* YES* YES Handwriting Recognition YES YES NO Built-in Voice Recorder YES YES NO Compact Flash Card Slot YES YES NO Secure Digital Card Slot YES YES NO Battery Life 14 hours** 14 hours** 130 hours Instrument Comes With Pocket Word, Excel, Contacts, Tasks, Calculator and other Microsoft Applications YES YES NO ACCESSORIES Hands-Free Operational Soft Case and Probe Pouch YES YES NO GrayWolf IAQ Surveyor II and IAQ SurveyorPro GrayWolf DS IAQ Kit GRAYWOLF FEATURES COMPARISON Page 3 of 4 graywolf iaq monitors *Virtual keyboard included. Optional folding or roll-up, full-sized keyboards **Mobile PC with backlight off. Not including probe battery life (typically 120+ hours) (probe may be worn behind to minimize breathing on sensors) GrayWolf DS IAQ Plus Kit (probe may be worn behind to minimize breathing on sensors) Hard shell Security Case secures instrument and probe during fi eld use and can be used as a shippable enclosure YES (unit is truly designed for both semi-permanent and walk-thru surveys) YES (unit is truly designed for both semi-permanent and walk-thru surveys) NO (yet not so small that it is easily “pocketed”) Extended Life Batteries OPTIONAL OPTIONAL NO 2 ½ inch Belt IR printer OPTIONAL OPTIONAL NO 8 ½ inch serial printer OPTIONAL OPTIONAL OPTIONAL 8 ½ inch Bluetooth wireless printer OPTIONAL OPTIONAL NO Full-sized Bluetooth Fabric or Folding Keyboard OPTIONAL OPTIONAL NO Portable Air Pump to draw samples across sensors OPTIONAL OPTIONAL OPTIONAL User Gas Calibration Kit OPTIONAL OPTIONAL OPTIONAL User %RH Calibration Kit OPTIONAL OPTIONAL OPTIONAL Barcode Wand OPTIONAL OPTIONAL NO GPS Kit OPTIONAL OPTIONAL NO 3rd Party HVAC, IH, FM & other application software OPTIONAL OPTIONAL NO GrayWolf DS IAQ Kit GRAYWOLF FEATURES COMPARISON Page 4 of 4 graywolf iaq meters GrayWolf DS IAQ Plus Kit GrayWolf IAQ Surveyor II and IAQ SurveyorPro
Most popular related searches