General Monitors by MSA
  1. Companies & Suppliers
  2. General Monitors by MSA
  3. Downloads
  4. IR700 Point IR CO2 Gas Detector Data ...

IR700 Point IR CO2 Gas Detector Data Sheet

Toxic GasMODEL IR700Features• No routine calibration required• True fail-to-safe operation • Multiple communication outputs• Event logging • Heated optics • Dirty optics indication• Wireless capabilityBenefits• Low maintenance• True gas detection performance• Provides complete status and control capability in the control room• Stores fault, gas check, calibrationand alarm event history• Eliminates condensation• Discriminates between true fault and cleaning requirements• Compatible with ELPROTechnologies wireless devicesDescriptionThe Model IR700 infrared (IR) point detector is amicroprocessor-based carbon dioxide gas detector thatcontinuously monitors CO2 in ppm levels. The IR700 detection principle is based on measuringthe absorption of infrared radiation passing through avolume of gas using a dual beam, single detector method.The IR detector measures the intensity of two specificwavelengths, one at an absorption wavelength andanother outside of the absorption wavelength. The gasconcentration is determined by a comparison of thesetwo values.All of the IR700’s electronics are contained within anexplosion-proof housing allowing detector information tobe processed at the point of detection. The IR700provides 4-20 mA signal proportional to 0-100% fullscale. In addition, the IR700 is equipped with Modbus orHART. Configurations with relays, Modbus, and HARTare available.The IR700 is calibrated at the factory and needs noroutine field calibration. It requires only a periodiccleaning of the windows and re-zeroing to ensuredependable performance.The IR700 IR point detector is available in either analuminum or stainless steel housing and is designed foruse in Class I, Div. 1, Groups B, C & D and Zone 1 areasfor North America and Zones 1 and 21 internationally. Thehousing is IP66/ Type 4X rated.Applications• Carbon Capture and Storage• Enhanced Oil Recovery• Chemical Plants• Fertilizers• Food & Beverage Bottling Plants• Coal Gasification• Metals• Wastewater Treatment FacilitiesProtection for life.GENERAL MONITORSInfrared Carbon DioxidePoint DetectorToxic GasMODEL IR700System SpecificationsDetector Type: Infrared absorption typeMeasuringRange: 0 to 5000 ppmConsult factory for other rangesGases: Carbon Dioxide (CO2)Detector Life: Greater than 5 yearsAccuracy: ± 5% full scale = 2500 ppm± 10% full scale > 2500 ppmResponse (with 100% FS gas applied)Time: T50 = 4 s, T90 = 8 sModes:? Self test, normal operation,calibration (zero only orcomplete calibration)Accessories: IR4000S CO2 monitor, junctionbox, duct mount junction box,calibration cup, flow block,splash guard, rain guard, portablepurge calibratorClassification: Class I, Divisions 1 & 2, Groups B, C & D (Ta = -40°C to +75°C) Type 4X Ex d, IIB+H2 T5 Gb, IP66(Ta = -60°C to +75°C)Ex t IIIC T100°C DbWarranty: Two yearsApprovals: CSA, ATEX, IECEx, CE Marking. HART Registered. Environmental Specifications Operating Temperature Range:-40°F to +122°F (-40°C to +50°C)Storage Temperature Range:-76°F to +185°F (-60°C to +85°C)Humidity: 10% to 95% RH, non-condensingMechanical SpecificationsDiameter: 2.9 inches (74 mm)Length: 8.87 inches (225 mm)Weight: 3 lbs (1.35 kg) - aluminum6 Ibs (2.7 kg) - stainless steelMounting: 3/4" NPTHousing: Aluminum 6061-T6 alloy or316 stainless steelExplosion Proof, IP66, Type 4xElectrical SpecificationsInput Power: 20-36 VDC24 VDC @ 200 mA max. Analog Signal: 4-20 mA (600 ohms max.)Start up, Fault (non-HART) 0 mAStart up, Fault (HART)* 1.25 mACal, Zero, Gas Check* 1.5 mADirty Optics* 2.0 mA0 to 100% LEL 4 to 20 mA(proportional)Over-range 21.7 mA* Under HART, the analog output minimum level can be configured as3.5 mA or as stated above, depending on user selection.RS-485 Output: Modbus RTU, suitable for linking upto 128 units or up to 247 units withrepeaters Baud Rate: 2400, 4800, 9600, or 19200 BPSHART: HART 6, HART Device Description(Optional) available. AMS Device Manager supportRFI /EMIProtection: Complies with EN 50270,EN 61000-6-4Sample CableRequirements: For cable resistance of 3 ohms/1,000 ft,maximum distance between IR4000Sand power source @ 24 VDC:14 AWG (2.5 mm2) - 3,330 ft (1,110 m)For 16 AWG cable with cableresistance of 5 ohms /1,000 ft,maximum distance of analog output(100 ohms max.): 10,000 ft. (3,050 m)FaultsMonitored: Calibration errors, EPROM andEEPROM Checksum Errors,Optics Failure /Blockage;Low Supply Voltage WirelessCommunication: Available with ELPRO Technologieswireless devicesStandard Configuration: IR700-0-2-1-2-1 0-5000 ppm range, aluminum housing,splashguard w/screen, no junction boxSpecifications subject to change without notice.Represented by:Publication #: DS-IR700-B0312Lake Forest, CA26776 Simpatica CircleLake Forest, California 92630Tel: +1-949-581-4464Fax: +1-949-581-1151email: info@generalmonitors.comHouston, TX9776 Whithorn DriveHouston, Texas 77095Tel: +1-281-855-6000Fax: +1-281-855-3290email: gmhou@generalmonitors.comIrelandBallybrit Business ParkGalwayRepublic of IrelandTel: +353-91-751175Fax: +353-91-751317email: info@gmil.ieSingaporeNo. 2 Kallang Pudding Road#09-16 Mactech BuildingSingapore 349307Tel: +65-6748-3488Fax: +65-6748-1911email: genmon@gmpacifica.com.sgUnited Arab EmiratesP.O. Box 61209Jebel AliDubaiUnited Arab EmiratesTel: +971-4-8143814Fax: +971-4-8857587Email: gmme@generalmonitors.aeUnited KingdomHeather CloseLyme Green Business ParkMacclesfield, CheshireUnited Kingdom, SK11 0LRTel: +44-1625-619583Fax: +44-1625-619098Email: info@generalmonitors.co.ukWuxi General Monitors A joint venture157 Hubin Road, C-11 1F Wuxi, Jiangsu Province 214073People's Republic of ChinaTel: +86-510-8512 2222Fax: +86-510-8512 8222email: sales@wxglt.comGeneral MonitorsWorldwidewww.generalmonitors.com
Most popular related searches