S4000TH H2S Gas Detector

H2SMODEL S4000THFeatures• Event logging• 4-20mA output• HART and Modbus communication• Detection Ranges(0-20 ppm, 0-50 ppm, 0-100 ppm)• Warning, Alarm & Fault Relays • Calibration, Calibration Check,Set-up Mode• Remaining Sensor Life Indication• Wireless capabilityBenefits• Stores fault, gas check, calibration,and alarm event history• Industry standard output for remotealarm and fault indication• Provides complete status and controlcapability in the control room• Wider range of applications• Provides local alarm capability• Simplifies operation and maintenance• Reduces downtime by providing anestimate of remaining sensor life• Compatible with ELPRO Technologieswireless devicesDescriptionThe Model S4000TH Intelligent Sensor is amicroprocessor-based transmitter designed for use withGeneral Monitors ' Metal Oxide Semiconductor (MOS)sensor. This unit features one person calibration andcan virtually self-calibrate by simply activating amagnetic switch and applying gas. It is designed todetect hydrogen sulfide in parts per million (ppm) levelsand provide status indication and alarm outputs.All of the S4000TH electronics are contained within anexplosion-proof housing so that sensor information canbe processed at the sensor site. It provides a 4-20 mAsignal which is proportional to 0 to 100% of the detectionrange at the sensor. In addition, the S4000TH includeswarning, alarm and fault relay contacts that can be usedto indicate an alarm or fault condition, and dualredundant Modbus or HART communications.Configurations with relays, Modbus and HART are availableto meet many needs.The S4000TH includes a three (3) digit LED display.This local digital display continuously indicates gasconcentrations during normal operation and in thecalibration check mode, calibration prompts duringcalibration mode, display codes during the setup modeand eight fault codes. The S4000TH has four different operating modes. First,the normal operating mode in which alarms are active andthe display and 4-20 mA readings are proportional to thegas concentration at the sensor. Second, the gas checkmode that allows the user to apply a gas and check thesensor response while alarm outputs are inhibited. Third,a calibration mode in which gas is applied to the sensor tocalibrate the unit. Finally, a set-up mode which allows theuser to review or change setup options such as relaysettings, sensor range, and Modbus parameters.Selecting Setup Mode on the S4000TH is accomplishedby using the magnetic switch, HART or Modbus command.Options• Sensor Range (0-20 ppm, 0-50 ppm, 0-100 ppm)• Energized/de-energized relays• Latching/non-latching relays• Alarm setpoints for relays• Baud rate, data format, and address for eachModbus channelProtection for life.GENERAL MONITORSIntelligent Sensor forH2S Gas DetectionH2SMODEL S4000THwww.generalmonitors.comLake Forest, CA26776 Simpatica CircleLake Forest, California 92630Tel: +1-949-581-4464Fax: +1-949-581-1151Email: info@generalmonitors.comHouston, TX9776 Whithorn DriveHouston, Texas 77095Tel: +1-281-855-6000Fax: +1-281-855-3290Email: gmhou@generalmonitors.comIrelandBallybrit Business ParkGalwayRepublic of IrelandTel: +353-91-751175Fax: +353-91-751317Email: info@gmil.ieSingaporeNo. 2 Kallang Pudding Road#09-16 Mactech BuildingSingapore 349307Tel: +65-6748-3488Fax: +65-6748-1911Email: genmon@gmpacifica.com.sgUnited Arab EmiratesP.O. Box 61209Jebel AliDubaiUnited Arab EmiratesTel: +971-4-8143814Fax: +971-4-8857587Email: gmme@generalmonitors.aeUnited KingdomHeather CloseLyme Green Business ParkMacclesfield, CheshireUnited Kingdom, SK11 0LRTel: +44-1625-619583Fax: +44-1625-619098Email: info@generalmonitors.co.ukGeneral MonitorsWorldwideSystem SpecificationsSensor Type: Continuous diffusion,adsorption type Metal OxideSemiconductor (MOS)Sensor Life: 3 to 5 years typicalRepeatability: ±2 ppm or 10% of the appliedgas, whichever is greaterResponse Time: T50 <10 seconds (screen)T50 <30 seconds (sintered)with full scale gas appliedMeasuringRanges: 0-20 ppm, 0-50 ppm, 0-100 ppmModes: Calibration, calibration check, setupElectrical Classification:CSA/FM Class I, Division 1, Groups B,C & D; Class I, Zone 1 IIB+H2, T6. Type 4X(Tamb = -40°C to +60°C)ATEX EEx d IIB+H2, T5 II2G, IP66(Tamb = -40°C to +70°C)Warranty: Two yearsApprovals: ATEX, CSA, FM, CE Marking,HART registered, SIL 2 and 3suitable*, FM certified to IEC 61508Environmental Specifications Operating Temperature Range:Electronics -40°F to 167°F (-40°C to 75°C)Std. Sensor (CSA) -40°F to 167°F (-40°C to 75°C)Std. Sensor (FM) -40°F to 140°F (-40°C to 60°C)Std. Sensor (ATEX) -40°F to 248°F (-40°C to 120°C)Storage TemperatureRange: -58°F to 185°F (-50°C to 85°C)Operating HumidityRange: 5% to 100% RH, non-condensingMechanical SpecificationsLength: 6.4 inches (161mm) Height: 3.4 inches (86mm)Width: 4.1 inches (104mm)Weight: 5.5 lbs. (2.5 kg)Mounting Holes: 5.0 inches (127mm)(center to center)Electrical SpecificationsInput Power: 24 VDC nominal, 20 to 36 VDC350 mA max.Relay Ratings: 8A @ 250 VAC / 8A @ 30 VDC(optional) res. max.(3x) SPDT - Warning, Alarm & FaultAnalog Signal: 0-20 mA (650 Ohms max. load)Malfunction 0 mA**Gas Check/Cal 1.5 mA***Setup mode 1.5 mA***Zero reading 4 mA+0.2 mA0-100% scale 4-20 mAOver-range 20-22 mARFI/EMIProtection: Complies with EN50270,EN61000-3-2, EN61000-3-3Status Indicators: Three-digit LED display with gasconcentration, Warn and AlarmLED's, calibration prompts, faultcodes, and setup options RS-485 Output: Modbus RTU, suitable for(optional) linking up to 128 units or up to247 units with repeatersBaud Rate: 2400, 4800, 9600, or 19200 BPSHART: HART 6, HART Device (optional) Description Language available.AMSAwareWirelessCommunication: Available with ELPROTechnologies wireless devicesFaults Monitored: Calibration error, sensorheater error, low DC supply,EEPROM, EPROM, setup error,gas check time exceeded,switch input error, internal errorsCable Requirements: 3 wire shielded cable. Max. distancebetween S4000TH and powersource or remote sensor @ 24 VDCnominal (20 Ohm loop):14 AWG - 2240 ft. (824 m)Max. distance for analog output(600 Ohms max):14 AWG - 8000 ft. (2400 m)Standard Configuration: S4000TH-1-0-01-1(4-20 mA, P/N 50445-1, 0-100 ppmaluminum sensor, push terminals)Specifications subject to change without notice.Represented by:Publication #: DS-S4000TH-C1010* Use in typical environments has a lower safety rating than in clean environments** Under HART, current values can be either 3.5 mA or 1.25 mA, depending on user selection*** Under HART, current value can be either 3.5 mA or 1.5 mA, depending on user selection
Most popular related searches