Labkotec Oy
SET-2000 Hi Level/Oil Brochure
Labkotec OyMyllyhaantie 6FI-33960 Pirkkala, FINLANDTel. int. +358 (0)29 006 260Fax int. +358 (0)29 006 1260E-mail: info@labkotec.fiwww.labkotec.comwww.labkonet.comData sheetMeasure your successSET-2000 Hi Level/OilDocument nr D15534_e1/2012Labkotec Oy reserves the rights to alterations without prior notice. Due to policy of continuous improvement in R&D, technical specifications may change. Installation shall always be made as documented in manufacturer's instructions.SET-2000 Hi Level/Oiloil separator alarm deviceThe SET-2000 Hi Level/Oil is equipped with twosensors, one indicates the oil layer and the otherindicates blockage detection. i.e. high level incase of sewer blockage or closure of the closingdevice.SET-2000 control unit,SET/DM3AL and SET/V sensorsMounting holes diameter ø 4,5 mmEnclosure depth 75 mmMounting dimension 160 mm Mounting dimension 110 mmDimensionsControl unit SET-2000 Hi Level/OilDimensions: 175 mm x 125 mm x 75 mm (L x H x D)Material: PolycarbonateEnclosure: IP65Operation temperature: -25 °C...+50 °CSupply voltage: 230 VAC ± 10 %, 50/60 HzFuse 5 x 20 mm 125 mAT (IEC/EN 60127-2/3)The device is not equipped with a mains switchPower consumption: 4 VASensors: Two Labkotec SET sensors (SET/DM3AL, SET/V)Max. resistance of thecurrent loop between thecontrol unit and a sensor: 75 ORelay outputs: Two potential-free relay outputs 250 V, 5 A, 100 VAOperational delay 5 sec or 30 sec. Relays de-energizeat trigger point. Operation mode selectable forincreasing or decreasing level.Electrical safety: EN 61010-1, Class II , CAT II/IIIInsulation level probe/mains supply voltage: 375 V (IEC/EN 60079-11)EMC: IEC/EN 61000-6-3 (Emission)IEC/EN 61000-6-2 (Immunity)Ex-classification: II (1) G [Ex ia] IICSpecial conditions (Ta = -25 °C...+50 °C)ATEX VTT 04 ATEX 031XIECEx IECEx VTT 10.0003XElectrical parameters: Uo = 14,7 V Io = 55 mACharacteristic curve of Po = 297 mW R = 404 Othe output voltage istrapezoidalManufacturing year: xxx x xxxxx xx YY xPlease see the serial Where YY = manufacturing yearnumber on the type plate (e.g. 10 - 2010)130 mm 172 mm216 mmø 25 mmReferenceelectrodeMeasureelectrodeSET/DM3ALJunction boxAccessories:Cable jointSensor SET/DM3AL SET/VPrinciple of operation: Conductivity VibrationMaterial: PVC (black), AISI 316, NBR, PA PVC, aluminium, NBR, PAEnclosure: IP68 IP68Temperature: Operation 0 °C...+60 °C Operation 0 °C...+60 °CSafety -30 °C...+60 °C Safety -30 °C...+60 °CSignal: Analog 3 mA/10 mA Digital and analogical 7 mA/13 mASupply voltage: 8 V...16 V (DC) 8 V...16 V (DC)Cable: Shielded oil-proof cable Shielded oil-proof cable2 x 0,75 mm2, standard length 5 m 2 x 0,75 mm2, standard length 5 mEMC: IEC/EN 61000-6-3 (Emission) IEC/EN 61000-6-3 (Emission)IEC/EN 61000-6-2 (Immunity) IEC/EN 61000-6-2 (Immunity)Ex-classification: II 1 G Ex ia IIA T5 Ga II 1 G Ex ia IIB T5 GaATEX VTT 09 ATEX 026X VTT 09 ATEX 025XIECEx IECEx VTT 10.0001X IECEx VTT 10.0006XElectrical parameters: Ui = 16,5 V Ii = 80 mA Ui = 16 V Ii = 80 mAPi = 400 mW Ci = 3,5 nF Pi = 400 mW Ci = 3500 pFLi = 85 µH Li = 85 µHManufacturing year: x xxx x xxxxx xx YY x xxx x xxxxx xx YY xPlease see the serial Where YY = manufacturing year Where YY = manufacturing yearnumber on the type (e.g. 10 - 2010) (e.g. 10 - 2010)plateApplicationOilWaterSET/ DM3ALsensorSET-2000JunctionboxSET/VsensorSET/V100 mm125 mmø 25Sensingelement146 mm
Most popular related searches
