Waltron Bull & Roberts, LLC.
- Home
- Companies & Suppliers
- Waltron Bull & Roberts, LLC.
- Downloads
- Single Point Sample Conditioning ...
Single Point Sample Conditioning Modules - Brochure
WALTRON SERIES Single Point SampleConditioning ModulesWaltron Series Single Point Sample Conditioning Modules help tolower temperature and pressure of single point samples providingversatility to your system. Modules can be used before continuousanalysis instruments or used to obtain grab samples. The mainbenefits of using a sample conditioning module are to protectanalyzers and personnel and to ensure analyzer accuracy.FEATURESModules are pre-engineered to your specifications Module delivered assembled with only cooling water, sample and drain connections required for start-upList of options accommodates conditioning for any sampleConvenient stainless steel sink holds grab sample bottle and acts as drainHandles wide range of samples, pressures and temperatures for peak performanceUnit is compact and lightweightVariety of analyzers can be mounted directly onto unit with larger plateBENEFITSMinimal maintenanceProtection of instrumentationEnsure correct sampling conditionsSAMPLE SPECIFICATIONSPressure: Low Pressure: 0 – 1000 psig / 70 bar; High Pressure: 1000 – 5000 psig / 350 barTemperature: Low Temp: 0 – 450°F / 232°C; High Temp: up to 1000°F / 537°CFlow: Up to 1500 ml/minCOOLING WATER SPECIFICATIONSPressure: 35 – 150 psig / 2.45 – 10.5 barTemperature: Up to 100°F / 37°CFlow: 4 – 12 gpm / 15.14 – 45.43 ml/minCooling water inlet/ from 3/8” FNPT to 3/4” FNPToutlet connections:SYSTEM SPECIFICATIONSBackplate: 17“ x 27“ / 43.1 x 68.58 cm; 304SS Grab sample sink: 304SS with 1/2” FNPT drain connectionHigh pressure inlet valve: 1/4”OD compression type (for hot liquid) or 3/8”OD compression type (for steam). Inlet valve packing can be Teflon, PEEK or Grafoil.Coolant isolation and BNZthrottling valves:High temp thermal 304SS (for 0 – 3000 psi) or 316SS (for > 3000 psi)shut-off valve:High pressure 316SSreducing valve:Temperature gauge: 0 – 200°F / 93°C; 316SSPressure gauge: 0 – 60 psig / 0 – 4.2 bar; 316SSBack pressure regulator: 0 – 50 psig / 0 – 3.5 bar; 316SSAnalyzer flowmeter: 20 – 240 ml/min; acrylic and 316SS; with 1/4“ compression fitting outletGENERA L S P EC I F I CAT IONSWALTRON, L.L.C.50 Tannery Road, PO Box 70, Whitehouse, NJ 08888-0070 Phone: 800-242-7353 • Outside the US: 908-534-5100 Fax: 908-534-5546 • www.waltron.netWALTRON B.V.PO Box 7089, 5980 AB Panningen, The NetherlandsPhone: +31-77-3082955Fax: +31-77-3082956 • www.waltron.netHOW TO ORDER: WALTRON SAMPLE CONDITIONING MODULEPRESSURE REDUCER(provide pressure & flow requirements)0 Not included1 Sample pressure up to 1000 psig / 70 bar2 Sample pressure 1000 to 5000 psig / 350 barSAMPLE COOLER0 Not included1 Standard capacity 1.0 sq ft / 0.09 m22 Medium capacity 2.4 sq ft / 0.22 m23 High capacity 3.5 sq ft / 0.33 m2SAMPLE SHUT-OFF VALVEL Sample temperature up to 450°F / 232°CM Sample temperature 450 to 750°F / 232°C to 399°CH Sample temperature 750 to 1000°F / 399°C to 537°CSAMPLE BLOWDOWN VALVE0 Not included1 IncludedTOTAL SAMPLE FLOW INDICATOR10 Not included1 IncludedPRESSURE & TEMPERATURE GAGES0 Not included1 Pressure gage 0 – 60 psig / 0 – 4.2 bar2 Temperature gage 0 – 200°F / 0 – 93 bar3 Pressure and temperature gageSAMPLE TO ANALYZER CONTROL0 None required1 Shut-off valve22 Flowmeter2 30 – 300 cc/min COOLING WATER CONTROL3 1 Relief valve2 Shut-off valve (inlet)3 Sight flow indicator1. The Total Flow Indicat or is recommended as an indication of Cooler load. Cooler life can be extended by controlling total sample flow.2. Includes Pressure Regulator.3. An outlet Throttling Valve is included as standard. A Relief Valve is recommended for safety purposes when the sample inlet exceeds 450°F / 232°C. The Shut-Off Valve allows for Cooler isolation. The Sight Flow Indicator provides positive indication of coolant flow.
Most popular related searches
