Johnson Controls, Inc.

VD-1330 Series - Control Damper Brochure

Code No. LIT-1923140accordance with accepted industry practices to ensure proper system performance.Repair InformationJohnson Controls VD-1300 dampers have no components that require routine scheduled maintenance.If the VD-1300 Volume Control Damper fails to operate within its specifications, replace the unit. For a replacement VD-1300 damper, contact the nearest Johnson Controls representative. Refer to the VD-1300 Volume Control Dampers Product Bulletin (LIT-1201635) for for important product application information and a list of repair parts available.VD-1300 SeriesControl DamperDescriptionSince 1905, Johnson Controls has provided the highest quality control dampers that fit your application and size requirements.• VD-1330 - Airfoil-shaped aluminum blades/galvanized frame• VD-1320 - Double-piece blades/galvanized frame• VD-1310 - 16-gauge blades/galvanized frame (Not for outdoor air applications)The VD-1300 dampers are designed to control the flow of air in Heating, Ventilating, and Air Conditioning (HVAC) systems, and to meet different application and environmental requirements. These applications include, but are not limited to:• volume (air) control applications, which regulate the flow of air• temperature control applications, which maintain a constant temperature• pressure control applications, which maintain a constant pressureDampers are tested at an Air Movement Control Association (AMCA) Certified Laboratory using instrumentation and procedures in accordance with AMCA Standard No. 500, Test Methods for Louvers, Dampers, and Shutters. The VD-1300 Series includes Class IA, I, and III leakage-rated dampers, available in 1-inch increments.Features• tested to over 100,000 cycles assures long damper life.• 3-year warranty on materials and workmanship provides confidence of company standing behind product.• 3-working-day standard shipping after order entry results in fast response for short lead time projects.• 1-working-day Fast Track shipping provides Fast Track at a cost premium.• factory-installed actuator reduces installation and commissioning time.• factory-installed jackshaft reduces installation and commissioning time.V(ASFVF1mtfsaB1wsoPsaLdscdddt91SatVCSFCdF1mtfsaBeDapsThe performance specifications are nominal and conform to acJohnson Controls, Inc. shall not be liable for damages resultinD-1310 Class III DampersNot for Outdoor Air pplications) Submittal pecificationsurnish and install Johnson Controls® D-1310 Class III volume control dampers.rames are to be constructed of formed 3-gauge galvanized sheet steel, echanically joined with linkage concealed in he side channels to eliminate noise and riction. Compressible spring stainless steel ide seals and self-lubricating bearings shall lso be provided.lades are to be constructed with formed 6-gauge galvanized steel. Damper blade idth shall not exceed 8 inches and shall have eals. Blade rotation is to be parallel or pposed as shown on the schedules.erformance shall be designed for normal hutoff in return air applications and tested in ccordance with AMCA Standard 500. eakage resistance for a 48-inch x 48-inch amper with seals shall not exceed 17 cfm per quare foot at a 1-inch pressure differential, 45 fm per square foot at a 4-inch pressure ifferential. Damper operating force at a 4-inch ifferential shall not exceed 6 lb·in/sq ft. The amper must be rated to operate over a emperature range of -40 to 200°F (-40 to 3°C) standard and -40 to 250°F (-40 to 21°C) high temperature.izing shall be determined by the designer in ccordance with accepted industry practices o ensure proper system performance.D-1320 Class I or VD-1330 lass IA Dampersubmittal Specificationsurnish and install Johnson Controls VD-1320 lass I or VD-1330 Class IA volume control ampers.rames are to be constructed of formed 3-gauge galvanized sheet steel, echanically joined with linkage concealed in he side channel to eliminate noise and riction. Compressible spring stainless steel ide seals and self-lubricating bearings shall lso be provided.lades are to be constructed with 1/16-inch xtruded aluminum in an airfoil shape. amper blade width shall not exceed 8 inches nd shall have seals. Blade rotation is to be arallel or opposed as shown on the chedules.ceptable industry standards. For applications at conditions beyong from misapplication or misuse of its products. © 2009 Johnson1 of 3Issued February 18, 2009VD-1300 Control DampersPerformance shall be designed for very tight shutoff and tested in accordance with AMCA Standard 500. Leakage resistance for a 48-inch x 48-inch damper with seals shall not exceed 2.2 cfm per square foot at a 1-inch pressure differential, 3.7 cfm per square foot at a 4-inch pressure differential. Damper sealing force at a 4-inch differential shall not exceed 6 lb·in/sq ft. The damper must be rated to operate over a temperature range of -40 to 200°F (-40 to 93°C) standard and -40 to 250°F (-40 to 121°C) high temperature.Sizing shall be determined by the designer in d these specifications, consult the local Johnson Controls office. Controls, Inc. www.johnsoncontrols.comControl Damper (Continued)Selection ChartOrdering Code Number1 V - w w w x h h hApplication V = Volume ControlBlade Operation O = OpposedP = ParallelAccessoriesDescription11. For complete listing and pictures, refer to the Damper Accessory Kits and Replacement Parts Product Bulletin (LIT-2681100).Kit NumberBlade Pin Extension Support Bracket DMPR-KC0013-1/4 in. Blade Pin Extension DMPR-KC00215 in. Blade Pin Extension DMPR-KC004Blade Pin Extension Coupler DMPR-KC0065 in. Blade Pin Extension DMPR-KC007Crank Arm, 7/16 in. Shaft, Adjustable 1 to 2-3/4 in. Radius DMPR-KC050Blade Arm DMPR-KC054Internal Vertical Blade-to-Blade Linkage DMPR-KC100External Vertical Pin-to-Pin Linkage DMPR-KC101Linkage Rod, 4 ft DMPR-KC102Horizontal Face/Bypass Bracket DMPR-KC150Horizontal Blade-to-Blade Bracket DMPR-KC15190° Blade-to-Blade Linkage DMPR-KC152Support Bar DMPR-KC200Damper Fastener DMPR-KC201Pin-to-Pin Coupling DMPR-KC202Drive Arm and U-Bolt DMPR-KC203Manual Locking Quadrant DMPR-KC250Factory OptionsE Exact whole inch size, no undercutF 1.5 in. L flange air entering side(cannot be used with option G or H)G 1.5 in. L flange air leaving side(cannot be used with option F or H)H Double flange(cannot be used with option F or G)I Indicator switch (DMPR-KC014)J Jackshaft (field installed) (factory assembles and breaks down for shipping)M Jackshaft (factory installed and assembled)Q Internal mount actuatorThe performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office.Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. © 2009 Johnson Controls, Inc. www.johnsoncontrols.com2 of 31. Not all combinations are available, check selector tool for valid combinations.Blade/Frame A = Aluminum Airfoil/13-gauge GalvanizedP = Double-Piece/13-gauge GalvanizedV = 16-gauge/13-gauge GalvanizedBearing/Seal S = Standard (Acetal/Santoprene)E = Extended (Bronze/Santoprene)H = High (Bronze/Silicone)Actuator A = M9206-AGB or M9220-AGCB = M9206-GGB or M9220-HGCC = M9206-BAB or M9220-BACD = M9206-BGB or M9220-BGCF = M91xx-AGC-2G = M91xx-xGC-2N = NoneP = Pneumatic 8-13 lb spring rangeWidth VD-1310: 008 to 108 inches, 1 in. incrementsVD-1320/VD-1330: 008 to 192 inches, 1 in. incrementsHeight VD-1310: 006 to 076 inches, 1 in. incrementsVD-1320/VD-1330: 006 to 228 inches, 1 in. incrementsOptions(limit two)See Factory Options for descriptions and combinations.Control Damper (Continued)Technical SpecificationsVD-1300 Series Control Dampers11. All Performance data is determined using instrumentation and procedures at an AMCA Certified Laboratory in accordance with AMCA Standard No. 500, Test Methods for Louvers, Dampers, and Shutters.Leakage Resistance VD-1310 17 cfm/sq ft maximum at 1 in. static pressure45 cfm/sq ft maximum at 4 in. static pressureVD-1320 3.4 cfm/sq ft maximum at 1 in. static pressure6.0 cfm/sq ft maximum at 4 in. static pressureVD-1330 2.2 cfm/sq ft maximum at 1 in. static pressure3.7 cfm/sq ft maximum at 4 in. static pressureOperating Torque 0.5 in. static pressure and 100 fpm fully open approach velocity1 in. static pressure and 1,000 fpm fully open approach velocity4.5 lb·in/sq ft5.5 lb·in/sq ftPressure Drop (inches WG) - Fully OpenSize (in.) Approach Velocity (fpm)1,000 2,000 3,000 4,00012 x 12 0.16 0.42 -- --24 x 24 0.05 0.20 0.42 0.5748 x 48 0.03 0.10 0.25 0.45Velocity Requirements Width (in.)12 24 36 48VD-1310 6,000 fpmat 6 in. static4,500 fpmat 6 in. static3,000 fpmat 4.5 in. static1,500 fpmat 3 in. staticVD-1320 8,000 fpmat 8 in. static6,000 fpmat 8 in. static4,000 fpmat 6 in. static2,000 fpmat 4 in. staticVD-1330 8,000 fpmat 12 in. static8,000 fpmat 10 in. static6,000 fpmat 10 in. static4,000 fpmat 4 in. staticTemperature Rating Normal and Extended Operating Conditions -40 to 200°F (-40 to 93°C)High (with Bronze Bearings and Silicone Seals) -40 to 250°F (-40 to 121°C)Actuator -4 to 122°F (-20 to 50°C)Approximate Weight Damper 5 pounds/square foot (2.7 kg/sq ft)Actuator 2.9 pounds (1.6 kg) per actuatorThe performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office.Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. © 2009 Johnson Controls, Inc. www.johnsoncontrols.com3 of 3
Most popular related searches