Crowcon Detection Instruments Ltd
Xsafe - Robust Flammable Gas Detector for Non-Hazardous Areas Datasheet
CO2H2SCI2NH3O3COO2CH4SO2CO2H2SFixed detectors for flammable, toxic or oxygen gasesXgard Type 1: Intrinsically safe toxic and oxygen gas detectorXgard Type 2: Flameproof toxic and oxygen gas detectorXgard Type 3: Flameproof flammable gas detectorXgard Type 4: Flameproof high temperature flammable gas detectorXgard Type 5: Flameproof flammable gas detector with 4-20mA outputXgard Type 6: Flameproof thermal conductivity type gas detectorXsafe: Safe area flammable gas detectorXgardXgardThe Xgard range of gas detectors has been specifically designed to meet your requirements. The dangers presented by toxic and flammable gases as well as oxygen deficiency vary with each application.Xgard offers three different sensor concepts so you can choose exactly what you need for your site. Xgard is available in flameproof, intrinsically safe or safe area formats for use in all environments, whatever the classification.Low cost of ownership• Xgard detectors are designed for easy installation and maintenance to keep costs down.• The three junction box options are all designed to make replacement of sensors and sinters extremely simple.Spare sensors simply plug-in.• Many spare parts are common to all Xgard models, which keeps spares holding requirements to a minimum.Flexible installation options• Xgard is designed for either wall or ceiling mounting without the need for additional brackets.• Xgard can accommodate M20, 1/2” NPT or3/4” NPT cable glands to suit all site requirements.• High temperature models are available for hot environments (up to 150oC).• Accessories are available for duct mounting and sampling applications as well as remote gassing for simple sensor checking.Wide range of sensorsXgard offers an extremely wide range of sensors for all applications:• Poison resistant pellistors, for all flammable detection needs including hydrocarbons, hydrogen, ammonia, jet fuel, leaded petrol and vapours containing halogens.• Electrochemical sensors are used to detect a vast range of toxic gases and oxygen.• Thermal conductivity sensors are available to monitor volume concentrations of gases.Rugged and reliable• Xgard is manufactured using a choice of three materials: glass reinforced nylon, highly durable aluminium with a tough polyester coating, or 316 stainless steel for ultimate corrosion resistance. All versions are designed to operate even in the harshest conditions.• Spray deflectors and weatherproof caps are available for use in areas subject to regular wash-downs, or offshore environments.• All models have been validated to the functional safety standard IEC 61508 (SIL 1 to SIL 3).Accessories(all accessories require an Accessory Adaptor to be fitted to the Xgard junction box)For outdoor use and protection against wash-down operations.Spray DeflectorFor use where a detector is installed in direct sunlightSun ShieldFor use in very wet conditions, such as offshore installations and ships.Weatherproof CapFor aiding detection of gases which are lighter than air, such as hydrogen and methane.Collector ConeFor use in sampling applications.Flow AdaptorFor fitting accessories to Xgard.Accessory AdaptorXgard labelAmplifier PCBUniversal junction box‘O’ ringPlug-in sensor moduleWall mounting lugsPCB coverScrew-on lidSensor retainer with sinter on flameproof modelsM20, 1/2” or 3/4” cable entryCeiling mounting lugsThe Xgard range offers a comprehensive selection of fixed point gas detectors that meet the diverse requirements for flammable and toxic gas detection and oxygen monitoring in industries throughout the world.This diagram is designed to help you choose the correct Xgard detector to suit your needs.Detector SelectorOrdering RequirementsThe following code is designed to help in the selection of the correct detector. The product reference number should be compiled by inserting the appropriate integer in each box.*1: Xgard Type 1 ATEX certified detectors will be supplied in a glass-reinforced nylon enclosure as standard, or in a 316 stainless steel enclosure as an option. Xgard Type 1 UL certified detectors and all other Xgard Types will be supplied in aluminium as standard, or in a 316 stainless steel enclosure as an option.*2: The stainless steel option is not available for Xsafe and Xgard type 4. Example product reference for an I.S. 0-25ppm H2S detector with ATEX certification and M20 cable entry in a standard (nylon) junction box: XGARD/1/A/M20/AT/H2S/25.Gas HazardTOXIC OR OXYGEN FLAMMABLE% VolumeGas ConcentrationsCO2, CH4, He, Ar ZONE 1 OR 2, DIV 1 OR 2 ZONE 0,1 OR 2, DIV 1 OR 2 ZONE 1 OR 2, DIV 1 OR 2 ZONE 1 OR 2, DIV 1 OR 2SAFE AREA Xgard Type 6 Xsafe Xgard Type 1 Xgard Type 2 Xgard Type 4 Xgard Type 5 Xgard Type 3Flameproof electrochemical type detector with 2-wire 4-20mA output.Intrinsically Safe electrochemical type detector with 2-wire 4-20mA output. Wide range of sensor options. A zener barrier or galvanic isolator is required for I.S. operation.Flameproof thermal conductivity type detector with 3-wire 4-20mA output. Flameproof high temperature (up to 150oC) catalytic bead type detector with mV bridge output.Flameproof catalytic bead type detector with 3-wire 4-20mA output.Non-certified low cost catalytic bead type detector with 3-wire 4-20mA or mV bridge output.Flameproof catalytic bead type detector with 3-wire mV bridge output. Detector Type No. Code Output Junction Box Code Cable Entry Code Certification Code Gas Type RangeXGARD Type 1 1 Standard*1 A M20 M20 ATEX AT Abbreviated up From selection XSAFE Type 2 2 Stainless Steel*2 S 1/ 2”NPT 1/ 2 UL UL to 8 characters shown on tableType 3 3 3/ 4”NPT 3/ 4Type 4 4Type 5 5Type 6 6XSAFE XS mV or mANotes: Other sensors and ranges may be available, please contact Crowcon. *Ranges not available for Xsafe or Xgard Type 4 †Contact Crowcon for availability LTEL & STEL figures are derived from the UK HSE document: EH40 Oct 07. Alternative thresholds may apply in countries outside of the UK LEL figures derived from EN61779-1: 2000 *1 Current limits advised in the UK *2 Nominal 0-100ppm range with Carbon Monoxide (CO). Contact Crowcon for a full list of gases that can be detected using this sensorXgard Gases and Ranges:Gas type LTEL(ppm) STEL(ppm) Ranges Available: Ranges Available: Ranges Available: Ranges Available: LEL(%vol) UEL(%vol) Type 1 Type 2 Type 3,4,5 & Xsafe Type 6Acetylene (C2H2) 2.3 (2.4) 100 0-100% lel*Ammonia (NH3) 25 35 50, 100, 250, 0-25%lel* 15 (15) 33.6 (28) 500, 1000 ppm Argon (Ar) - - Contact CrowconArsine (AsH3) 0.05 - 1 ppmBromine (Br2) 0.1 0.2 3 ppmButane (C4H10) 1.4 (1.8) 9.3 (9) 0-100% lel* Carbon Dioxide 5000 15000 Contact Crowcon (CO2) (0.5%Vol) (1.5%Vol) Carbon Monoxide 30 200 50, 100, 200, 250, 50, 100, 250, 500, (CO) 500, 1000, 2000 ppm 1000, 2000 ppm Chlorine (Cl2) - 0.5 3,5,10,20,50,100 ppmChlorine Dioxide 0.1 0.3 1 ppm (ClO2)Diborane (B2H6) 0.1 - 1 ppmEthane (C2H6) 2.5 (3) 15.5 0-100% lel*Ethylene (C2H4) 2.3 (2.7) 36 0-100% lel*Ethylene Oxide 5 - 10, 50, 100 ppm (C2H4O)Fluorine (F2) 1 1 1 ppmGermane (GeH4) 0.2 0.6 2 ppmHelium (He) - - Contact Crowcon Hydrogen (H2) 4 77 (80) 200, 2000 ppm 200, 2000 ppm 0-100% lel* 0-5%, 10%, 50% vv (in air) 0-20%, 25%, 30%, 50% vv (H2 in N2)Hydrogen Chloride 1 5 10, 25 ppm (HCl)Hydrogen Cyanide - 10 25ppm (HCN)Hydrogen Fluoride 1.8 3 10 ppm(HF)Hydrogen Sulphide 5 10 5, 10, 20, 25, 50, 5, 10, 20, 25, 50 (H2S) 100, 200, 250, 300, 100, 200 ppm 1000 ppmLPG 2 10 0-100% lelMethane (CH4) 4.4 (5) 17 (15) 0-100% lelNitric Oxide (NO) 5*1 15*1 25, 50, 100 ppmNitrogen Dioxide 1 1 10, 50, 100 ppm (NO2)Ozone (O3) - 0.2 1 ppmOxygen (O2) - - 25% Vol 25% VolPentane (C5H12) 1.4 (1.5) 7.8 (7.8) 0-100% lel* 600ppm 1800ppmPetrol Vapour 1.3 6 0-100% lel*Phosgene (COCl2) 0.02 0.06 1 ppmPhosphine (PH3) 0.1 0.2 1 ppmPropane (C3H8) 1.7 (2.2) 10.9 (10) 0-100% lelSilane (SiH4) 0.5 1 1 ppmSulphur Dioxide (SO2) 1 1 10, 20, 50, 100, 250 ppm Vinyl Chloride 3.6 33 0-100% lel*(VCM) (CH2=CHCl) 3 -Volatile Organics - - 0 - 100 ppm*2(VO)*2 * 3/4" cable entry only available on aluminium junction boxes* 3/4" cable entry only available on aluminium junction boxesP03018GB Issue 7 January 2010UK: 2 Blacklands Way, Abingdon Business Park, Abingdon, OXON, OX14 1DY +44 (0) 1235 557700 sales@crowcon.comUS: 21 Kenton Lands Road, Erlanger, Kentucky 41018-1845 +1 859 957 1039 salesusa@crowcon.comNL: Vlambloem 129, 3068JG, Rotterdam +31 10 421 1232 eu@crowcon.comSG: Block 194 Pandan Loop, #06-20 Pantech Industrial Complex, Singapore, 128383 +65 6745 2936 sales@crowcon.com.sgwww.crowcon.comArea reserved for distributor stampXgard Specification:Xgard Model Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 XsafeJunction box ATEX Certified: Glass- Aluminium Aluminium Aluminium Aluminium Aluminium Aluminium material reinforced nylon or or 316 Stainless or 316 Stainless or 316 Stainless or 316 Stainless 316 S/S UL Certified: Steel Steel Steel Steel Aluminium or 316 S/S. Dimensions 156 x 166 x 156 x 166 x 156 x 166 x 195 x 166 x 156 x 166 x 156 x 166 x 156 x 166 x 111mm (6.1 x 6.5 111mm (6.1 x 6.5 111mm (6.1 x 6.5 111mm (7.6 x 6.5 111mm (6.1 x 6.5 111mm (6.1 x 6.5 111mm (6.1 x 6.5 x 4.3 inches) x 4.3 inches) x 4.3 inches) x 4.3 inches) x 4.3 inches) x 4.3 inches) x 4.3 inches)Weight Nylon 0.5Kg (1.1lbs) AL 1Kg (2.2 lbs) AL 1Kg (2.2 lbs) 1.5Kg (3.3 lbs) AL 1Kg (2.2 lbs) AL 1Kg (2.2 lbs) 1Kg (2.2 lbs) Alloy 1Kg (2.2 lbs) 316 S/S: 3.1kg (6.8 lbs) 316 S/S: 3.1kg (6.8 lbs) 316 S/S: 3.1kg (6.8 lbs) 316 S/S: 3.1kg (6.8 lbs) 316 S/S: 3.1kg (6.8 lbs)Ingress IP65 IP65 IP65 IP54 IP65 IP65 IP65 protection Cable entries 1 x M20 or 1 x M20, 1 x M20, 1 x M20, 1 x M20, 1 x M20, 1 x M20, or 1 /2” NPT 1 /2” NPT or 3 /4” NPT* 1 /2” NPT or 3 /4” NPT* 1 /2” NPT or 3 /4” NPT* 1 /2” NPT or 3 /4” NPT* 1 /2” NPT or 3 /4” NPT* 1 /2” NPT on right-side on right-side on right-side on right-side on right-side on right-side on right-sideTerminations 0.5 to 2.5mm2 0.5 to 2.5mm2 0.5 to 2.5mm2 0.5 to 2.5mm2 0.5 to 2.5mm2 0.5 to 2.5mm2 0.5 to 2.5mm2 (20 to 13awg) (20 to 13awg) (20 to 13awg) (20 to 13awg) (20 to 13awg) (20 to 13awg) (20 to 13awg)Sensor type Electrochemical Electrochemical Catalytic bead 316 s/s Catalytic bead Thermal Catalytic bead sensor housing conductivity with catalytic beadsOperating -20 to +50oC -20 to +50oC -40 to +80oC -20 to +150oC -40 to +55oC +10 to +55oC -40 to +80oCtemperature (-4 to 122oF) (-4 to 122oF) (-40 to 176oF) (-4 to 302oF) (-40 to 131oF) (50 to 131oF) (-40 to 176oF) (sensor dependant) (sensor dependant) (mV version) -40 to +55oC (-40 to 131oF) (mA version)Humidity 15-90% RH 15-90% RH 0-99% RH 0-99% RH 0-99% RH 0-90% RH 0-99% RH non-condensing non-condensing non-condensing non-condensing non-condensing non-condensing non-condensingRepeatability <2% FSD (Typ.) <2% FSD (Typ.) <2% FSD (Typ.) <2% FSD (Typ.) <2% FSD (Typ.) <2% FSD (Typ.) <2% FSD (Typ.)Zero drift <2% FSD / month <2% FSD / month <2% FSD / month <2% FSD / month <2% FSD / month <2% FSD / month <2% FSD / month (Typ.) (Typ.) (Typ.) (Typ.) (Typ.) (Typ.) (Typ.)Response time T90 <10s Oxygen T90 <10s Oxygen T90 <15s (Typ) T90 <15s (Typ) T90 <15s (Typ) T90 <15s (Typ) T90 <15s (Typ) T90 <30s to 120s T90 <30s to 120s Toxic (sensor Toxic (sensor dependant) dependant)Operating 8 – 30V dc 8 – 30V dc 2.0V dc +/- 0.1V 2.0V dc +/- 0.1V 10 – 30V dc 10 – 30V dc 10 – 30V dc voltage (Typ) (Typ) (mA version) 2.0V dc (mV version)Power 24mA max. 24mA max. 300mA (Typical) 300mA (Typical) 50mA @ 24V 50mA @ 24V mA version: requirements dc 1.2W dc 1.2W 50mA @ 24V dc 1.2W. mV version: 300mA (Typ.)Electrical 2-wire 4-20mA 2-wire 4-20mA 3-wire mV bridge 3-wire mV bridge 3-wire 4-20mA 3-wire 4-20mA mA version: output (current sink) (current sink) Typical signal Typical signal (current sink or (current sink or 3-wire 4-20mA 12-15mV / %lel >10mV / %lel source) source) (current sink or CH4 CH4 source) mV version: 3-wire mV bridge Typical signal 12-15mV / %lel CH4Approvals ATEX: II 1 G ATEX: II 2 GD ATEX: II 2 GD ATEX: II 2 G ATEX: II 2 GD ATEX: II 2 GD Not certified Exia IIC T4 Exd IIC T6 Exd IIC T4 Exd IIC T3 Exd IIC T6 Exd IIC T6 for use in a (Tamb –40 to (Tamb –40 to (Tamb –40 to (Tamb –20 to (Tamb –40 to (Tamb –40 to hazardous +55oC) +50oC) +80oC) +150oC) +50oC) +50oC) environment. UL/cUL: Cl I, Div 1 UL: Class 1, Div. 1 Exd IIC T6 Exd IIC T4 Exd IIC T4 Groups A,B,C,D Groups B,C,D Tamb (-40 to +50oC) (Tamb –40 to +80oC) (Tamb -40 to +80oC) IECEx IECEx UL: Class 1, Div. 1 UL: Class 1, Div. 1 UL: Class 1, Div. 1 MED Marine MED Marine Groups B,C,D Groups B,C,D Groups B,C,D (Oxygen Only) (Oxygen Only) IECEx IECEx IECEx GOST-R GOST-R GOST-R GOST-R GOST-R EMC EN 50270 EN 50270 EN 50270 EN 50270 EN 50270 EN 50270 EN 50270 compliance FCC Part 15 FCC Part 15 FCC Part 15 FCC Part 15 FCC Part 15 FCC Part 15 FCC Part 15 ICES-003 ICES-003 ICES-003 ICES-003 ICES-003 ICES-003 ICES-003
Most popular related searches
