Zenit Europe S.A.
Zenit - DGE - Set-Back Vortex Impeller for Submersible Electric Pumps Brochure
36DGE40 °C6 ÷ 141 mm2/s20 m1 Kg/dm370 dB30submersible pumps PRODUCT CATALOGUE 2013ApplicationsConstruction materialsOperating limitsMaximum operating temperaturePH of treated fluidViscosity of treated fluidMaximum immersion depthDensity of treated fluidMaximum acoustic pressureMax starts per hourCast iron EN-GJL 250Cast iron EN-GJL-250Stainless steel - Class A2-70 Rubber - NBR Stainless Steel - AISI 420Suitable with slightly soiled biological wastewaters and sewage. Suitable for domestic and residential use. Electromechanical assembly in GJL-250 cast iron, for submerged operation. Seal set comprising 1 (one) sili-con carbide mechanical seal and 1 (one) lip seal. Ecological dry motor.CaseImpellerNuts and boltsStandard gasketShaftSet of standard mechanical sealsGeneral characteristicsSet-back vortex impellerElectromechanical assemblyGAS 2” verticalGAS 2”- DN50 horizontalEcological bicomponent epoxy (medium thickness 80 µm)Paint typeset-back vortex impellermotor powerpolesdischargefree passagemax flow ratemax headOne silicon carbide mechanical seal (SiC) and one lip seal11.6 l/s15.7 m0,37 ÷ 1,5 kW2max 50 mmAll product images are indicative only37DGEsubmersible pumpsPRODUCT CATALOGUE 2013HandleMotorImpeller Free passageCapacitor/relayMechanical sealsAISI 304 stainless steel lifting and carrying handle.Ecological dry motor with thermal protections.Cast iron vortex impeller. Wide free passage allowing the expulsion of solids and preventing fouling of the impeller.Single-phase models with internal capacitor. Three-phase models with motor protection relay (option).One mechanical seal in silicon carbide (SiC) and one lip seal.2233551144663838l/s 0 2 4 6 8l/min 0 120 240 360 480 m3/h 0 7.2 14.4 21.6 28.8DGE 100/2/G40V A0CM(T)/50 13.7 11.1 7.9 3.7DGE 150/2/G40V A0CM(T)/50 15.9 13.1 9.8 5.7DGE 200/2/G40V A0CM(T)/50 17.5 14.7 11.6 7.9 3.5DGE 100/2/G40V A0CM/50 230 1 - 0.88 6.0 2900 Dir G 1½” A 40 mmDGE 150/2/G40V A0CM/50 230 1 - 1.1 7.6 2900 Dir G 1½” A 40 mmDGE 200/2/G40V A0CM/50 230 1 - 1.5 8.9 2900 Dir G 1½” A 40 mmDGE 100/2/G40V A0CT/50 400 3 - 0.88 2.0 2900 Dir G 1½” B 40 mmDGE 150/2/G40V A0CT/50 400 3 - 1.1 2.46 2900 Dir G 1½” B 40 mmDGE 200/2/G40V A0CT/50 400 3 - 1.5 3.2 2900 Dir G 1½” B 40 mmV P1 (kW) P2 (kW) A Rpm ØV A Rpm ØP1 (kW) P2 (kW)StartStartDGE213submersible pumps PRODUCT CATALOGUE 2013Phases Cable (*)PerformancesTechnical dataPhases Cable (*)Models with vertical GAS 1½” threaded discharge - 2 polesFree passageFree passage(*) A = H07RN-F 3G1 - 5 m cable length. Optional 10 m cable length with schuko plug. B = H07RN-F 4G1 - 10 m cable lengthAttention: Standard EN 60335-2-41 requires the use of a 10 m cable length in outdoor applicationsQ (l/min)Q (m3/h)H (m)21321321339l/s 0 2 4 6 8 10l/min 0 120 240 360 480 600 m3/h 0 7.2 14.4 21.6 28.8 36.0DGE 50/2/G50V B0BM(T)/50 6.1 4.9 2.6DGE 75/2/G50V B0BM(T)/50 8.0 6.7 4.7 2.0DGE 100/2/G50V B0CM(T)/50 12.0 10.1 7.9 5.6 3.4DGE 150/2/G50V B0CM(T)/50 13.9 11.9 9.6 7.2 4.8 2.4DGE 200/2/G50V B0CM(T)/50 15.7 13.6 11.2 8.8 6.3 3.9DGE 50/2/G50V B0BM/50 230 1 - 0.37 2.8 2900 Dir G 2” A 40 mmDGE 75/2/G50V B0BM/50 230 1 - 0.55 3.6 2900 Dir G 2” A 40 mmDGE 100/2/G50V B0CM/50 230 1 - 0.88 6.5 2900 Dir G 2” A 50 mmDGE 150/2/G50V B0CM/50 230 1 - 1.1 8.2 2900 Dir G 2” A 50 mmDGE 200/2/G50V B0CM/50 230 1 - 1.5 9.4 2900 Dir G 2” A 50 mmDGE 50/2/G50V B0BT/50 400 3 - 0.37 1.1 2900 Dir G 2” B 40 mmDGE 75/2/G50V B0BT/50 400 3 - 0.55 1.3 2900 Dir G 2” B 40 mmDGE 100/2/G50V B0CT/50 400 3 - 0.88 2.2 2900 Dir G 2” B 50 mmDGE 150/2/G50V B0CT/50 400 3 - 1.1 2.6 2900 Dir G 2” B 50 mmDGE 200/2/G50V B0CT/50 400 3 - 1.5 3.6 2900 Dir G 2” B 50 mmDGEV P1 (kW) P2 (kW) A Rpm ØV A Rpm ØP1 (kW) P2 (kW)StartStartsubmersible pumpsPRODUCT CATALOGUE 2013Phases Cable (*)PerformancesTechnical dataPhases Cable (*)Models with vertical GAS 2” threaded discharge - 2 poles(*) A = H07RN-F 3G1 - 5 m cable length. Optional 10 m cable length with schuko plug. B = H07RN-F 4G1 - 10 m cable lengthAttention: Standard EN 60335-2-41 requires the use of a 10 m cable length in outdoor applicationsFree passageFree passageQ (l/min)Q (m3/h)H (m)421534215342153421534040l/s 0 2 4 6 8 10l/min 0 120 240 360 480 600 m3/h 0 7.2 14.4 21.6 28.8 36.0DGE 50/2/G50H A1BM/50 6.7 5.3 3.4 1.0DGE 75/2/G50H A1BM/50 8.3 6.3 4.3 2.2DGE 100/2/G50H A0CM/50 12.6 10.2 7.8 5.3 2.8DGE 150/2/G50H A0CM/50 13.8 11.9 9.8 7.5 5.1 2.7DGE 200/2/G50H A0CM/50 15.5 13.2 10.8 8.3 6.0 3.7DGE 50/2/G50H A1BM/50 230 1 - 0.37 2.8 2900 Dir G2” - DN50 PN10-16 A 40 mmDGE 75/2/G50H A1BM/50 230 1 - 0.55 3.6 2900 Dir G2” - DN50 PN10-16 A 40 mmDGE 100/2/G50H A0CM/50 230 1 - 0.88 6.5 2900 Dir G2” - DN50 PN10-16 A 50 mmDGE 150/2/G50H A0CM/50 230 1 - 1.1 8.2 2900 Dir G2” - DN50 PN10-16 A 50 mmDGE 200/2/G50H A0CM/50 230 1 - 1.5 9.4 2900 Dir G2” - DN50 PN10-16 A 50 mmDGE 50/2/G50H A1BT/50 400 3 - 0.37 1.1 2900 Dir G2” - DN50 PN10-16 B 40 mmDGE 75/2/G50H A1BT/50 400 3 - 0.55 1.3 2900 Dir G2” - DN50 PN10-16 B 40 mmDGE 100/2/G50H A0CT/50 400 3 - 0.88 2.2 2900 Dir G2” - DN50 PN10-16 B 50 mmDGE 150/2/G50H A0CT/50 400 3 - 1.1 2.6 2900 Dir G2” - DN50 PN10-16 B 50 mmDGE 200/2/G50H A0CT/50 400 3 - 1.5 3.6 2900 Dir G2” - DN50 PN10-16 B 50 mmDGEV P1 (kW) P2 (kW) A Rpm ØV A Rpm ØP1 (kW) P2 (kW)StartStartsubmersible pumps PRODUCT CATALOGUE 2013PerformancesTechnical dataPhases Cable (*)Phases Cable (*)Freepassage(*) A = H07RN-F 3G1 - 5 m cable length. Optional 10 m cable length with schuko plug. B = H07RN-F 4G1 - 10 m cable lengthAttention: Standard EN 60335-2-41 requires the use of a 10 m cable length in outdoor applicationsModels with horizontal GAS 2” threaded - DN50 PN10-16 flanged discharge - 2 polesFreepassageQ (l/min)Q (m3/h)H (m)2413524135241352413541NAE TTCTCDTCDTTCDGTTCGTCSTTCSGTTSTRTRGNCCCCEFTCGFT2SIC SICM SICAL 2SICALDGE 100/2/G40V A0CM/50DGE 150/2/G40V A0CM/50DGE 200/2/G40V A0CM/50DGE 100/2/G40V A0CT/50DGE 150/2/G40V A0CT/50DGE 200/2/G40V A0CT/50DGE 50/2/G50V B0BM/50DGE 75/2/G50V B0BM/50DGE 100/2/G50V B0CM/50DGE 150/2/G50V B0CM/50DGE 200/2/G50V B0CM/50DGE 50/2/G50V B0BT/50DGE 75/2/G50V B0BT/50DGE 100/2/G50V B0CT/50DGE 150/2/G50V B0CT/50DGE 200/2/G50V B0CT/50DGE 50/2/G50H A1BM/50DGE 75/2/G50H A1BM/50DGE 100/2/G50H A0CM/50DGE 150/2/G50H A0CM/50DGE 200/2/G50H A0CM/50DGE 50/2/G50H A1BT/50DGE 75/2/G50H A1BT/50DGE 100/2/G50H A0CT/50DGE 150/2/G50H A0CT/50DGE 200/2/G50H A0CT/50DGEsubmersible pumpsPRODUCT CATALOGUE 2013Versions availableMechanical sealsElectrical variants Cooling(Key to versions on page 16)4242A B C D E F G H J kgDGE 50/2/G50H A1BM(T)/50 220 80 365 65 G 2”-DN50 160 18 125 90° 12DGE 75/2/G50H A1BM(T)/50 220 80 365 65 G 2”-DN50 160 18 125 90° 14DGE 100/2/G50H A0CM(T)/50 270 110 455 110 G 2”-DN50 205 18 125 90° 19DGE 150/2/G50H A0CM(T)/50 270 110 455 110 G 2”-DN50 205 18 125 90° 20DGE 200/2/G50H A0CM(T)/50 270 110 455 110 G 2”-DN50 205 18 125 90° 21A B C D E F kgDGE 100/2/G40V A0CM(T)/50 260 100 405 125 G 1½” 205 19DGE 150/2/G40V A0CM(T)/50 260 100 405 125 G 1½” 205 20DGE 200/2/G40V A0CM(T)/50 260 100 405 125 G 1½” 205 21DGE 50/2/G50V B0BM(T)/50 230 80 385 120 G 2” 165 12DGE 75/2/G50V B0BM(T)/50 230 80 385 120 G 2“ 165 14DGE 100/2/G50V B0CM(T)/50 270 100 425 130 G 2” 205 19DGE 150/2/G50V B0CM(T)/50 270 100 425 130 G 2” 205 20DGE 200/2/G50V B0CM(T)/50 270 100 425 130 G 2” 205 21DGEDN50 PN 10-16submersible pumps PRODUCT CATALOGUE 2013Models with horizontal dischargeOverall dimensions and weightsModels with vertical dischargeDimensions in mmDimensions in mmAll weights and dimensions are indicative onlyAll weights and dimensions are indicative only43A B CDGE 100/2/G40V A0CM(T)/50 475 285 235DGE 150/2/G40V A0CM(T)/50 475 285 235DGE 200/2/G40V A0CM(T)/50 475 285 235DGE 50/2/G50V B0BM(T)/50 385 225 245DGE 75/2/G50V B0BM(T)/50 385 225 245DGE 100/2/G50V B0CM(T)/50 475 285 235DGE 150/2/G50V B0CM(T)/50 475 285 235DGE 200/2/G50V B0CM(T)/50 475 285 235DGE 50/2/G50H A1BM(T)/50 385 225 245DGE 75/2/G50H A1BM(T)/50 385 225 245DGE 100/2/G50H A0CM(T)/50 475 285 235DGE 150/2/G50H A0CM(T)/50 475 285 235DGE 200/2/G50H A0CM(T)/50 475 285 235DGEA B DCsubmersible pumpsPRODUCT CATALOGUE 2013Packaging dimensionNo. pieces per palletInstallations availableFor DGE 50-75 models each pallet (EUR 1000x1200 mm) is able to take 48 pieces.For DGE 100-150-200 models each pallet (EUR 1000x1200 mm) is able to take 32 pieces.Dimensions in mm All weights and dimensions are indicative only
Most popular related searches
