Zenit Europe S.A.
- Home
- Companies & Suppliers
- Zenit Europe S.A.
- Downloads
- Zenit - DRO - Multi-Channel Open ...
Zenit - DRO - Multi-Channel Open Impeller for Submersible Pump Datasheet
126DRO40 °C6 ÷ 141 mm2/s20 m1 Kg/dm370 dB30 submersible pumps PRODUCT CATALOGUE 2013General characteristicsElectromechanical assemblyMulti-channel open impellerMulti-channel open impellerApplicationsConstruction materialsOperating limitsMaximum operating temperaturePH of treated fluidViscosity of treated fluidMaximum immersion depthDensity of treated fluidMaximum acoustic pressuremax starts per hourCast iron EN-GJL 250 Cast iron EN-GJL-250Stainless steel - Class A2-70 Rubber - NBR Stainless steel - AISI 420 One silicon carbide mechanical seal (SiC) and one carbon-aluminium oxide mechanical seal (AL) Can be used with clear or slightly soiled wastewaters containing small solids, strained water, rainwater, seepage and water pumped from underground. Suitable for heavy-duty domestic and professional applica-tions Electromechanical assembly in GJL-250 cast iron, for submerged operation. Seal set comprising 1 (one) silicon carbide mechanical seal and 1 (one) graphite alumina mechanical seal, installed opposing with oil lubrication. Oil bath motor.CaseImpellerNuts and boltsStandard gasketShaftSet of standard mechanical sealsGAS 1¼” - 2” verticalGAS 2” - DN50 horizontalEcological bicomponent epoxy (medium thickness 80 µm)Paint typemotor powerpolesdischargefree passagemax flow ratemax head13.0 l/s18.4 m0,37 ÷ 1,5 kW2 max 15 mmAll product images are indicative only127DROsubmersible pumpsPRODUCT CATALOGUE 2013HandleMotorIntake strainerStructureMechanical sealsAISI 304 stainless steel lifting and carrying handle.Oil bath motor with thermal protections. Capacitor and overload protection in external cabinet.Intake strainer in stainless steel.Constructed in cast iron.One mechanical seal in silicon carbide (SiC) and one mechanical seal in alumina graphite (AL).Anti-clogging systemThe special design of the hydraulic part ensures the expulsion of suspended solids and prevents fouling of the impeller.223355114466128l/s 0 1 2 3 4 5 6l/min 0 60 120 180 240 300 360 m3/h 0 3.6 7.2 10.8 14.4 18.0 21.6DRO 50/2/G32V A0CM(T)/50 8.8 8.1 6.9 5.2 2.7DRO 75/2/G32V A0CM(T)/50 12.1 11.8 10.8 9.1 6.9 4.2 0.9DRO 50/2/G32V A0CM/50 230 1 - 0.37 2.9 2900 Dir G 1¼” A 15 mmDRO 75/2/G32V A0CM/50 230 1 - 0.55 3.9 2900 Dir G 1¼” A 15 mmDRO 50/2/G32V A0CT/50 400 3 - 0.37 1.1 2900 Dir G 1¼” A 15 mmDRO 75/2/G32V A0CT/50 400 3 - 0.55 1.4 2900 Dir G 1¼” A 15 mmDROV P1 (kW) P2 (kW) A Rpm ØV A Rpm ØP1 (kW) P2 (kW)StartStartsubmersible pumps PRODUCT CATALOGUE 2013PerformancesTechnical dataModels with vertical GAS 1¼” threaded discharge - 2 poles(*) A = H07RN-F 4G1 - 5 m cable length. Optional 10 m cable length Attention: Standard EN 60335-2-41 requires the use of a 10 m cable length in outdoor applicationsPhases Cable (*)FreepassagePhases Cable (*)FreepassageQ (l/min)Q (m3/h)H (m)21212121129l/s 0 2 4 6 8 10 12l/min 0 120 240 360 480 600 720 m3/h 0 7.2 14.4 21.6 28.8 36.0 43.2DRO 100/2/G50V A0CM(T)/50 12.4 11.5 10.0 7.9 5.0 1.1DRO 150/2/G50V A0CM(T)/50 16.3 15.2 13.8 11.9 9.3 6.0 2.1DRO 200/2/G50V A0CM(T)/50 18.4 17.1 15.6 13.9 11.7 8.6 4.5DRO 100/2/G50V A0CM/50 230 1 - 0.88 6.5 2900 Dir G 2” A 15 mmDRO 150/2/G50V A0CM/50 230 1 - 1.1 8.2 2900 Dir G 2” A 15 mmDRO 200/2/G50V A0CM/50 230 1 - 1.5 9.3 2900 Dir G 2” A 15 mmDRO 100/2/G50V A0CT/50 400 3 - 0.88 2.3 2900 Dir G 2” A 15 mmDRO 150/2/G50V A0CT/50 400 3 - 1.1 2.7 2900 Dir G 2” A 15 mmDRO 200/2/G50V A0CT/50 400 3 - 1.5 3.5 2900 Dir G 2” A 15 mm213213DROV P1 (kW) P2 (kW) A Rpm ØV A Rpm ØP1 (kW) P2 (kW)StartStartsubmersible pumpsPRODUCT CATALOGUE 2013PerformancesTechnical data(*) A = H07RN-F 4G1 - 5 m cable length. Optional 10 m cable length Attention: Standard EN 60335-2-41 requires the use of a 10 m cable length in outdoor applicationsPhases Cable (*)Phases Cable (*)Models with vertical GAS 2” threaded discharge - 2 polesFreepassageFreepassageQ (l/min)Q (m3/h)H (m)213213130l/s 0 2 4 6 8 10 12l/min 0 120 240 360 480 600 720 m3/h 0 7.2 14.4 21.6 28.8 36.0 43.2DRO 100/2/G50H A0CM(T)/50 12.4 11.5 10.0 7.9 4.9DRO 150/2/G50H A0CM(T)/50 16.3 15.2 13.8 11.9 9.3 6.0DRO 200/2/G50H A0CM(T)/50 18.4 17.1 15.6 13.9 11.7 8.6 4.5DRO 100/2/G50H A0CM/50 230 1 - 0.88 6.5 2900 Dir G 2”- DN50 PN10-16 A 15 mmDRO 150/2/G50H A0CM/50 230 1 - 1.1 8.2 2900 Dir G 2”- DN50 PN10-16 A 15 mmDRO 200/2/G50H A0CM/50 230 1 - 1.5 9.3 2900 Dir G 2”- DN50 PN10-16 A 15 mmDRO 100/2/G50H A0CT/50 400 3 - 0.88 2.3 2900 Dir G 2”- DN50 PN10-16 A 15 mmDRO 150/2/G50H A0CT/50 400 3 - 1.1 2.7 2900 Dir G 2”- DN50 PN10-16 A 15 mmDRO 200/2/G50H A0CT/50 400 3 - 1.5 3.5 2900 Dir G 2”- DN50 PN10-16 A 15 mm21321321 3DROV P1 (kW) P2 (kW) A Rpm ØV A Rpm ØP1 (kW) P2 (kW)StartStartsubmersible pumps PRODUCT CATALOGUE 2013PerformancesTechnical dataPhases Cable (*)Phases Cable (*)Models with horizontal GAS 2” threaded - DN50 PN10-16 flanged discharge - 2 poles(*) A = H07RN-F 4G1 - 5 m cable length. Optional 10 m cable length Attention: Standard EN 60335-2-41 requires the use of a 10 m cable length in outdoor applicationsFreepassageFreepassageQ (l/min)Q (m3/h)H (m)213131NAE TTCTCDTCDTTCDGTTCGTCSTTCSGTTSTRTRGNCCCCEFTCGFT2SIC SICM SICAL 2SICALDRO 50/2/G32V A0CM/50DRO 75/2/G32V A0CM/50DRO 100/2/G50V A0CM/50DRO 150/2/G50V A0CM/50DRO 200/2/G50V A0CM/50DRO 100/2/G50H A0CM/50DRO 150/2/G50H A0CM/50DRO 200/2/G50H A0CM/50DRO 50/2/G32V A0CT/50DRO 75/2/G32V A0CT/50DRO 100/2/G50V A0CT/50DRO 150/2/G50V A0CT/50DRO 200/2/G50V A0CT/50DRO 100/2/G50H A0CT/50DRO 150/2/G50H A0CT/50DRO 200/2/G50H A0CT/50A B C D E F kgDRO 50/2/G32V A0CM(T)/50 220 75 330 105 G 1¼” 155 15DRO 75/2/G32V A0CM(T)/50 220 75 330 105 G 1¼” 155 15.5DRO 100/2/G50V A0CM(T)/50 260 95 385 125 G 2” 195 19.5DRO 150/2/G50V A0CM(T)/50 260 95 385 125 G 2” 195 20.5DRO 200/2/G50V A0CM(T)/50 260 95 385 125 G 2” 195 21.5DROsubmersible pumpsPRODUCT CATALOGUE 2013Versions availableMechanical sealsElectrical variants CoolingOverall dimensions and weightsModels with vertical dischargeDimensions in mm All weights and dimensions are indicative only(Key to versions on page 16)132A B C D E F G H J kgDRO 100/2/G50H A0CM(T)/50 250 90 385 65 G 2”-DN50 195 18 125 90° 19.5DRO 150/2/G50H A0CM(T)/50 250 90 385 65 G 2”-DN50 195 18 125 90° 20.5DRO 200/2/G50H A0CM(T)/50 250 90 385 65 G 2”-DN50 195 18 125 90° 21.5A B CDRO 50/2/G32V A0CM(T)/50 385 225 245DRO 75/2/G32V A0CM(T)/50 385 225 245DRO 100/2/G50V A0CM(T)/50 475 285 235DRO 150/2/G50V A0CM(T)/50 475 285 235DRO 200/2/G50V A0CM(T)/50 475 285 235DRO 100/2/G50H A0CM(T)/50 475 285 235DRO 150/2/G50H A0CM(T)/50 475 285 235DRO 200/2/G50H A0CM(T)/50 475 285 235DROB C DAsubmersible pumps PRODUCT CATALOGUE 2013Models with horizontal dischargeDimensions in mmPackaging dimensionDimension in mmNo. pieces per palletInstallations availableFor DRO 50-75 models each pallet (EUR 1000x1200 mm) is able to take 48 pieces.For DRO 100-150-200 models each pallet (EUR 1000x1200 mm) is able to take 32 pieces.All weights and dimensions are indicative onlyAll weights and dimensions are indicative only
Most popular related searches
