Flame Detection Applications

8 Results found
Only show results available in Virginia?
OK
  • Category: Health & Safety ×

  • Subcategory: Flame Detection ×

Gas detection analyzers for chemical & pharmaceutical processes

by Control Instruments Corporation     based in Fairfield, NEW JERSEY (USA)

Chemical and pharmaceutical facilities use a variety of hazardous gases and solvents in their production processes. Whenever these substances are transported, processed or stored, the potential risks are high for hazardous conditions. These substances must be continuously monitored to protect personnel and facilities from accidental releases or leakage. Our various lines of hazardous gas monitoring systems benefit the chemical and pharmaceutical industry in the following applications.

Methane Sensing for Coal Mining

by Edinburgh Instruments Ltd     based in Livingston, UNITED KINGDOM

Application: The majority (around 60%) of the coal seams currently being extracted worldwide are so far underground that open cast mining cannot take place and, therefore, underground mining techniques need to be used. Consequently, workers have to enter and work in confined spaces. One of the major problems that this creates is the dangers from Methane (CH4) gas which occurs in Mine gas.

Measurement of methyl ethyl ketone, chloroform & carbon tetrachloride in air for remediation & super fund sites

by MOCON - Baseline     based in Lyons, COLORADO (USA)

The Series 8900 Analyzer provides direct measurement of Methyl Ethyl Ketone, Chloroform and Carbon Tetrachloride in ambient air. This instrument is utilized for remediation and Super Fund sites and to monitor workplace exposure limits.

Measurement of C1-C5 with carbon dioxide for oil & gas exploration.

by MOCON - Baseline     based in Lyons, COLORADO (USA)

The PetroAlert Model 8900 combines the selectivity of gas chromatography with the sensitivity, broad dynamic range, and hydrocarbon selectivity of a flame ionization detector (FID) providing fast analysis of C1-C5 hydrocarbons and Carbon Dioxide required in Mud Logging for Oil & Gas exploration. The PetroAlert Model 8900 uses a dual column configuration with timed backflush to vent which is used to strip off moisture and C6+ hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed sample volume is carried to the pre-cut column. Backflush of the pre-cut column is timed from sample injection so that only C1-C5 hydrocarbons are eluted from the pre-cut column to the analytical column. C6+ hydrocarbons on the pre-cut column are then vented. Then a third column is used in conjunction with a second 10-port valve for individual analysis of methane. C1-C5 hydrocarbons are separated on the analytical column and elute to the flame ionization detector (FID) for analysis.

CO gas monitoring for coal pulverising mills

by Codel International Ltd     based in Bakewell, UNITED KINGDOM

Our range of safety analysers can offer early detection of fire / explosive conditions. From CO monitors for pulverising coal mills through to UV flame and smoke detectors installed on oil rigs and the cross-channel passenger shuttles, operated by Eurotunnel.

Fast C1 to C5 - PetroAlert Series 9100

by MOCON - Baseline     based in Lyons, COLORADO (USA)

The PetroAlert® Series 9100 combines the selectivity of gas chromatography with the sensitivity, broad dynamic range, and hydrocarbon selectivity of a flame ionization detector (FID) providing a 30 second analysis of C1-C5 hydrocarbons required in Mud Logging for Oil & Gas exploration, while maintaining C1-C2 separation at 200:1 concentration ratios.

Infrared sources for industrial and safety sector

by Axetris Ag     based in Kaegiswil, SWITZERLAND

Axetris infrared sources are used in a variety of industrial applications: Combustible and Toxic Gas Detection, Refrigerant Monitoring, SF6 Monitoring, Fruit Ripening Monitoring, Flame Detection, Liquid Analysis using Attenuated Total Reflection ATR, Semiconductor Fabrication.

Gas detection analyzers for pollution control

by Control Instruments Corporation     based in Fairfield, NEW JERSEY (USA)

Government and environmental groups are forcing industries with medium to high VOC exhausts to reduce emissions by as much as 98%. Incineration using pollution control devices such as oxidizers and flare stacks is one way to bring the exhaust emissions in line with the regulations. Capturing and reusing solvent in a solvent recovery system is another way.

Need help finding the right suppliers?

Let the XPRTs do the work for you