Workplace Monitoring Applications

25 Results found
Only show results available in Virginia?
OK
  • Category: Health & Safety ×

  • Subcategory: Workplace Monitoring ×

Sound level measurement for safety regulations

by Casella     based in Kempston, UNITED KINGDOM

Hand held instruments for the measurement of an employee`s noise exposure. Frequency analysis within Sound Level Meters can also be used to determine the correct selection of hearing protection.

Indoor quality monitoring for health and safety

by Enviro Technology Services plc     based in Stroud, UNITED KINGDOM

Indoor air quality (IAQ) is a major influence on the health, comfort and productivity of a building’s occupants. With 90% of our time spent indoors, determining the quality of the air that surrounds us is important.

Short term noise measurement for safety consulting

by Casella     based in Kempston, UNITED KINGDOM

For environmental noise monitoring when short measurements are required using a hand held Sound Level Meter. This could be for boundary monitoring of industrial sites or noise surveys for planning purposes.

Gas monitoring instruments and systems for nickel refining

by Gasmet Technologies Oy     based in Helsinki, FINLAND

The mining industry uses chemicals as ‘flotation’ agents in the recovery of sulphide minerals containing metallic elements (e.g., copper, nickel, silver, gold) from ore slurries. Sodium ethyl xanthate (SEX) is one of most common flotation agents, and it decomposes to form ethanol, carbon disulfide CS2, and Carbonyl Sulfide COS. These harmful gaseous compounds must be monitored from the indoor air at the enriching plant.

Measurement solution for ambient air workplace monitoring

by Protea Limited     based in Middlewich, UNITED KINGDOM

Protea can supply fixed workplace monitoring systems that can measure single or multi-points about the workplace. Specifically designed analytical systems can ensure detection limits down to ppb levels can be achieved for multiple gases with a single instrument. Controlling software can run automatically, providing instantaneous or time-weighted average readings.

Measurement of acrylonitrile in ambient air for monitoring workplace exposure limits

by MOCON - Baseline     based in Lyons, COLORADO (USA)

The Series 8900 Acrylonitrile Analyzer provides direct measurement of Acrylonitrile in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits. The Series 8900 Acrylonitrile Analyzer employs a flame ionization detector (FID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Acrylonitrile and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. Acrylonitrile is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

Pulsar noise testing equipment for workplace sector

by Pulsar Instruments plc     based in Filey, UNITED KINGDOM

Workplace noise monitoring is an interesting subject that can appear complex, but it is always worth remembering what you are trying to achieve. This can be summarised as: ““Minimising or avoiding the risk of noise-induced hearing loss in the workplace to comply with local, noise-based, legislation”” Such legislation is usually based on a European Directive that is then modified to suit the needs of each particular country. For example, in the United Kingdom, the ‘The Control of Noise at Work Regulations 2005’ are based on the European Union Directive 2003/10/EC; usually called “The physical agents (noise)” directive and expanded upon by the Health & Safety Executive.

Measurement of diacetyl in ambient air to monitor workplace exposure limits.

by MOCON - Baseline     based in Lyons, COLORADO (USA)

The Series 8900 Diacetyl Analyzer provides direct measurement of Diacetyl in ambient air. This instrument is utilized for environmental monitoring and to monitor workplace exposure limits. The Series 8900 Analyzer for Diacetyl employs a photoionization detector (PID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Diacetyl and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. The Diacetyl is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

Measurement of formaldehyde in ambient air for monitoring workplace exposure limits

by MOCON - Baseline     based in Lyons, COLORADO (USA)

The Series 8900 Formaldehyde Analyzer provides direct measurement of Formaldehyde in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits. The Series 8900 Formaldehyde Analyzer employs a flame ionization detector (FID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Formaldehyde and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. Formaldehyde is separated from potentially interfering components on the analytical column and elute to the detector for analysis.