Gas Calibration Articles

  • Iron Ore Pelletizing Plants - Case Study

    Changing the iron ore processing chain The iron ore being mined globally can approximately be divided equally into boulders and fines. For further processing boulders have to be sized to 10-30 mm for blast furnaces and 6-18 mm for sponge iron plants. Iron ore in a finely ground state is not easily transported or readily processed .The iron ore pelletizing process agglomerates the fine ...

  • Primary Standard Gas Flow Calibration—The Only Guarantee of Accuracy

    At Sierra, we have a saying: “An instrument’s accuracy is only as good as its calibration.” The accuracy of your mass flow controller (MFC) is essential in assuring the efficiency, performance, and quality of your flow meter. In many cases, if your instrumentation is not calibrated, then a decline in performance is possible due to ...


    By Sierra Instruments, Inc.

  • Gas Dilution With The Equal Capillaries Technique

    The advantages of the equal capillaries technique are surprising and leads to reach accuracy values of one order of magnitude higher than all the other dynamic dilution techniques. This comparison will be supported by analyzing the accuracy available with two different techniques. Nozzles (sonic or non-sonic) technique With this technique, a series of different size nozzles is used ...


    By Be.T.A. Strumentazione Srl

  • Providing Precision Flow Control Solutions for Critical Biomolecular Research

    When scientists at the University of Nottingham’s Centre for Biomolecular Sciences (CBS) in the United Kingdom needed instrumentation to control the flow of gases in their research, they turned to Litre Meter, a UK distributor for Sierra Instruments, and the SmartTrak 100 series mass flow meters and ...


    By Sierra Instruments, Inc.

  • Commonly Asked Questions About Calibration Gas

    Argus-Hazco's Becky Schneider answers the most commonly asked questions about calibration gas. The questions range from disposal and refilling protocol to shelf life to MSDS availability. Argus-Hazco offers a complete line of reactive and non-reactive gases in cylinder sizes that range from 17 to 221 liters. We have a large collection of common blends and we can also accommodate virtually any ...


    By Argus-Hazco

  • FFP choose Systech’s oxygen permeation analyser for testing flexible films - Case Study

    FFP Packaging Solutions specialise in high quality printed and plain flexible packaging, heat seal lidding films and films for high temperature/oven use. Offering the food industry innovative flexible packaging solutions, FFP ensure that all the film materials used have been vigorously tested to ensure that the quality of the packaging is stable when used in different environmental conditions ...


    By Systech Instruments Ltd

  • Measurement of Sulfur in Refinery Flare Gas Streams for Compliance with EPA SubpartJ(a) Regulations

    The Challenge Measurement of high range and low range H,S in refinery flare gas streams for compliance with EPA regulation NSPS Subpart J(a). The rule has placed an extra investment and operational burden on petroleum refineries to meet the regulatory requirement. AMETEK offers an economical solution to meet the challenge with an emphasis on lower capital and operating cost along with ...

  • Sonic nozzles for gas calibrators, when simplicity provides accuracy!

    Gas analyser’s calibration is a task required in many applications according to either legislation or quality systems management. This is the case for Air Pollution Monitoring or Continuous Emissions Monitoring devices installed in cabinets, for continuous analysis in remote locations. Measurements in traces range are performed and analytical devices specifications need to be validated and ...


    By LNI Swissgas

  • Fixed Versus Portable Gas Detection – Which Is Better?

    Did you know that workers are needlessly injured every year as a result of leaking toxic or combustible substances? Such incidents are known to involve a wide range of hazardous gases (including ammonia, carbon monoxide, chlorine, hydrogen sulfide, hydrocarbon vapors and so on). The sad reality is that most of these accidents are avoidable if only the workplace is adequately monitored. This leads ...

  • Use of principal component analysis in conjunction with soft computing methods for investigating total sediment load transferability from laboratory to field scale

    This study quantitatively investigates the generalization from laboratory scale to field scale using the soft computing (expert) and the empirical methods. Principal component analysis is utilized to form the input vector for the expert methods. Five main dimensionless parameters are used in the input vector of artificial neural networks (ANN), calibrated with laboratory data, to predict field ...


    By IWA Publishing

  • G100 portable CO2 incubator analyser for incubators gas readings

    The Geotech G100, which measures CO2 from 0-20%, is used to demonstrate accurate and repeatable CO2 readings of the atmosphere inside incubators. In just a few seconds an embryologist is able to take a reading from various incubators, all of which will have a different means of sampling the air inside an incubator, without fully opening the inner door and adversely affecting the environment. It ...


    By Geotech

  • Introduction of ECU Calibration tool, STARS Calibrate

    The control of engine is becoming more complicated over the years for balancing clean exhaust gas with high merchantability in addition to the fuel mileage improvement demand today and is controlled by the computer, ECU (Engine Control Unit). As the example of complexes, there are the implementation of Variable Valve Technology, Direct Injection to Gasoline Engine/Common-Rail Injection to Diesel ...


    By HORIBA Europe GmbH

  • Gas Monitor Bump Testing vs Calibration

    We are often asked to explain the difference between calibrations and bump testing. This is a controversial subject. OHS would have you do a full calibration before each use. In practice, our customers come up with their own intervals. If the gas monitor is used infrequently, say once a month, it should be calibrated every time to give you confidence that the unit is going to respond as it ...

  • Wastewater Treatment Plant Monitors Greenhouse Gas Emissions

    Globally, little attention is paid to gaseous emissions from wastewater treatment processes. This contrasts greatly with the regulatory monitoring that is applied to the quality of water emissions from such facilities. However, in Helsinki, Finland, a large municipal wastewater treatment facility continuously monitors its emissions of greenhouse gases (GHGs) to help in the city’s efforts to ...


    By Gasmet Technologies Oy

  • Effect of the number and length of zonal isolations on pressure behaviour of horizontal wells

    Horizontal wells with multiple zonal isolations have become a common completion technique in the oil and gas industry. Sand problems, damaged zones, and water or gas coning are the main reasons for using isolators to sustain or improve oil and gas recovery. However, they have certain effects on pressure behaviour of horizontal wells. This paper introduces new analytical models for studying the ...


    By Inderscience Publishers

  • How to handle capillaries based dilution in a linear way

    Equal capillaries type gas dividers ara intrinsically digital : given the number of installed capillaries, this is the max number of possible dilutions.  The paper indicates how, by means of an electronic PID pressure regulation system and using calculated set points, the gas divider may be used linearly. The device BetaCAP30 did produce accurately  dilutions producing the set target ...


    By Be.T.A. Strumentazione Srl

  • Biotechnology and International Law

    As its title suggests, this book deals with possible impacts of modern biotechnology on international law and how international law can be adapted to meet the new challenges presented by such technology. It grew out of a collective research project in the period between 2003 and 2005 by a number of scholars and experts in this field, including academics, practitioners and officials of ...


  • Sitelab gains laboratory certification with New Jersey DEP

    Located in New Jersey?  Use UVF instead of Gas Chromatography to save time and money on your next project! The New Jersey Department of Environmental Protection is the first state regulatory agency in the country to approve and certify the use of field analytical methods as part of their "Triad Approach," without compromising data quality and reliability.  Using UVF for ...


    By Sitelab Corporation

  • Comparison of three global optimization algorithms for calibration of the Xinanjiang model parameters

    The Xinanjiang model, a conceptual rainfall-runoff (CRR) model with distributed parameters, has been successfully and widely applied to flood forecasting of large basins in humid and semi-humid regions of China. With an increasing demand for timely and accurate forecasts in hydrology, how to obtain more appropriate parameters for CRR models has long been an important topic. These models have a ...


    By IWA Publishing

  • Gas Safety in Confined Spaces

    Introduction An offshore worker ensures a vessel is safe to enter; a plant manager enters a small plant room; a contractor inspects the lining of a sewage pipe.  All these personnel face common dangers, despite working in widely different industries.  Gas-related injury poses a serious threat in any confined space where the free movement of air is limited. A confined space ...

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you