Only show results available in Virginia? Ok

Siloxanes Monitoring Equipment

  • Premium

    Model 25398 - SPB-Octyl Capillary GC Column

    L × I.D. 60 m × 0.53 mm, df 3.00 μmApplication: The low polarity of this column approaches squalane, making it substantially less polar than that of the widely used non-polar poly(dimethyl siloxane) columns. This column offers unique selectivity compared to non-polar and intermediate polarity columns, and can be used for confirmational ...

    By MilliporeSigma based in Bellefonte, PENNSYLVANIA (USA). from SPB-Octyl GC-MS Columns for PCB Congeners Product line

  • Premium

    Model 24218-U - SPB-Octyl Capillary GC Column

    L × I.D. 30 m × 0.25 mm, df 0.25 μmApplication: The low polarity of this column approaches squalane, making it substantially less polar than that of the widely used non-polar poly(dimethyl siloxane) columns. This column offers unique selectivity compared to non-polar and intermediate polarity columns, and can be used for confirmational ...

    By MilliporeSigma based in Bellefonte, PENNSYLVANIA (USA). from SPB-Octyl GC-MS Columns for PCB Congeners Product line

  • Premium

    Model 24219-U - SPB-Octyl Capillary GC Column

    L × I.D. 60 m × 0.25 mm, df 0.25 μmApplication: The low polarity of this column approaches squalane, making it substantially less polar than that of the widely used non-polar poly(dimethyl siloxane) columns. This column offers unique selectivity compared to non-polar and intermediate polarity columns, and can be used for confirmational ...

    By MilliporeSigma based in Bellefonte, PENNSYLVANIA (USA). from SPB-Octyl GC-MS Columns for PCB Congeners Product line

  • Premium

    Model 24232 - SPB-Octyl Capillary GC Column

    L × I.D. 30 m × 0.25 mm, df 1.00 μmApplication: The low polarity of this column approaches squalane, making it substantially less polar than that of the widely used non-polar poly(dimethyl siloxane) columns. This column offers unique selectivity compared to non-polar and intermediate polarity columns, and can be used for confirmational ...

    By MilliporeSigma based in Bellefonte, PENNSYLVANIA (USA). from SPB-Octyl GC-MS Columns for PCB Congeners Product line

  • Premium

    Model 24233-U - SPB-Octyl Capillary GC Column

    L × I.D. 60 m × 0.25 mm, df 1.00 μmApplication: The low polarity of this column approaches squalane, making it substantially less polar than that of the widely used non-polar poly(dimethyl siloxane) columns. This column offers unique selectivity compared to non-polar and intermediate polarity columns, and can be used for confirmational ...

    By MilliporeSigma based in Bellefonte, PENNSYLVANIA (USA). from SPB-Octyl GC-MS Columns for PCB Congeners Product line

  • Protea - ATEX Gas Analyser

    atmosFIR EX is an ATEX certified gas analyser system for measurement of industrial gases in a Zone 1 or Zone 2 area, providing a complete EX certified gas measurement system that meets both the sampling of non-flammable and flammable gases, utilizing Protea’s multigas atmosFIR FTIR gas analyser platform.

    By Protea Limited based in Middlewich, UNITED KINGDOM. from Gas Analyser Products Product line

  • Siloxane Monitor

    In-situ, online, simple -siloxane monitoring • Measurement of total Siloxanes in gas supply to CHP engines• Suitable for Anaerobic Digestion derived Bio Gas and Landfill gases• Constant monitoring once an hour, 24hrs a day 365 days a year• Data logging and remote communications available• Minimal maintenance and operator inputThe STS Siloxane ...

    By Safe Training Systems Ltd based in Wokingham, UNITED KINGDOM.

  • SAGPack - Siloxane Removal System

    The SAGPack system is designed to condition, compress, and remove moisture and siloxanes from biogas. It includes patented technology for stratifying the media and calibration of the siloxane removal capabilities of the system based on the different species identified during gas testing. System size is based on gas velocity, temperature, pressure, ...

    By Robinson Group LLC based in Bothell, WASHINGTON (USA).

  • Activated Carbon Process

    The system consists of a minimum of two towers, each having a bed of activated carbon. The gas travels through the carbon bed from bottom to top. Pressure drop through the bed and outlet concentrations are monitored to alert to a change in performance signaling the need to replace the carbon. To replace the carbon, the tower must be put ...

    By AirScience Technologies Inc. based in Montreal, QUEBEC (CANADA). from Siloxanes & VOC Removal Product line

  • SOXSIA - H2s Removal from Biogas System

    SOXSIA® (Sulphur Oxidation and Siloxane Adsorption) is a catalyst, for the adsorption of siloxanes from biogas in combination with H2S removal from dry gas. The favourable adsorption properties result in high-adsorption capacity and removal efficiency for contaminants present at moderate concentrations in gas flows. The selected extruded ...

    By Gastreatment Services B.V. based in Bergambacht, NETHERLANDS. from Biogas Installations Product line

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you