Adcon - Model TR1 -Combisensor Temperature / rel. Humidity
The Adcon TR1 was developed in order to offer a highly accurate sensor with excellent long-term stability for a very competitive price. The sensor is virtually maintenance free and provides excellent long-term stability.
A professional radiation shield protects the sensor from direct sunlight and provides sufficient ventilation. Solid UV resistant elements reflect radiation on their white surface, while the black inside absorbs accumulating heat.
A protective coating keeps dust and dirt off the surface of the humidity sensor element to reduce sensor drift, eliminate corrosion and to maintain accuracy over a long period of time. A plastic cap with a metal screen shields both sensing elements against insects, chemicals and all kinds of dirt.
The sensor is delivered completely assembled with its 5-element radiation shield, mast mounting gear for poles with a diameter of ~40mm and a 3m cable with 7-pin Binder connectors for Adcon RTUs.
- Meteorological and hydrographical weather stations
- Livestock monitoring
- Industrial monitoring
- Storage and silo monitoring
- General: :
- Supply Voltage : 4.5 ... 15 VDC
- Current consumption : < 1,5 mA typ.
- Operating Temperature : -40°C ... +60°C
- -40°F ... +140°F
- Operating Humidity : 0 ... 100% rH
- Material of radiation shield : PC
- Mounting material : Aluminum tube, PC brackets, pipe clamps of W4 stainless steel
- Material of sensor body : Tecapet
- Protection class : IP65
- Dimensions : L x W x H 450 x 100 x 170mm
- L x W x H 17.72 x 3.94 x 6.69 in.
- Weight : 600g / 1.3 lb.
- Cable and Connector : 3m cable with male 7-pin M9 Binder
- Mounting : Mast mounting brackets for 40mm pole, with 2 pipe clamps 32-50mm
- Relative Humidity: :
- Measuring Range : 0 ... 100%rH
- Accuracy at +20°C : ±1% rH from 0 - 90% rH
- ±2% rH from 90% - max. rH
- Temperature dependence : ±0.03% rH /°C
- Long-term stability : <1% rH per year
- Output signal : 0 ... 2.5 V
- Sensor element : capacitance, with protective coating (HC01)
- Temperature: :
- Measuring range : -40°C ... +60°C
- -40°F ... +140°F
- Accuracy at +20°C : ±0,1°C
- Repeatability, Linearity, Temp. Dependence : ±0,1°C
- Output signal : 0 ... 2.5V DC
- Sensor element : pt1000 DIN A