AirData - Model ADM-860C -Electronic Multimeter
The ADM-860C AirData Multimeters include an RS232 communication port, which allows serial output to a printer or computer.
Most popular related searches
- Air balance model
- 25 to 2500 cfm range
- Supply and exhaust
- Air density corrected
- Memory and averaging
- Velocity and pressure
- English and metric units
- Auto range and zero
- Velgrid and airfoil
- Flow and temperature
DIRECT DIGITAL READOUT IN ENGLISH AND METRIC UNITS
- AIR VELOCITY: ±3% of reading ± 7 fpm 50 to 8,000 fpm pitot tube (30,000 fpm FS); 50 to 5,000 fpm AirFoil; 50 to 2500 fpm VelGrid.
- DIFFERENTIAL PRESSURE: ±2% of reading ± 0.001 in wc from 0.0500 to 50.00 in wc, (0.0001 to 60 in wc FS); 20 psid safe pressure.
- TEMPERATURE: ±0.5? accuracy from 32? to 158?.
- AIR FLOW: Accuracy is ±3% of reading ±7 cfm from 100 to 2000 cfm; range is 25 to 2500 supply, 25 to 1500 exhaust with 8400 FlowHood.
- ABSOLUTE PRESSURE: ±2% of reading ±0.1 in Hg from 14 to 40 in Hg referenced to vacuum. 60 psia maximum safe pressure.
- AMBIENT RANGE: Full range compensation from 40? to 140?.
- AIR DENSITY CORRECTION: Local or standard (mass flow) air density correction range is 14 to 40 in Hg and 32? to 158?.
- POSITION SENSITIVITY: Unaffected by position.
- MEMORY: 100 readings, sequence labeled, sum, average, minimum and maximum.
- CALIBRATION: Calibration certified NIST traceable.
- READOUT: 10 digit, 0.4", high contrast, liquid crystal display.
- METER HOUSING: High impact, molded, "T" grade ABS.
- METER WEIGHT: 36 ounces (1.02kg), including batteries
- SIZE: 6.0" x 6.4" x 2.7" (15.2 x 16.3 x 6.9 cm)
- CONNECTIONS: 1/4" OD slip-on for 3/16" ID soft tubing.
- BATTERY LIFE: 3000 readings per charge, 500 recharge cycles.