Atomizing Systems, Inc.
- Home
- Companies
- Atomizing Systems, Inc.
- Products
- Atomizing - Fog Controls System
Atomizing - Fog Controls System
Atomizing Systems’ control components are critical to successful performance of the fog system. With standard features ranging from variable-Frequency-Drives to proportional speed control based on feedback of pressure, temperature and humidity sensors; and with optional timing and zone controls. We are prepared to provide just the right level of control for your fog project. All UL approved.
Most popular related searches
variable frequency drive
temperature and humidity sensor
pump station
remote humidity sensor
digital temperature controller
humidity sensor
water pressure too low
pump controller
remote sensor
humidity control
- Enclosure: containing all electrical control devices. Standard Constructionis watertight as in corrosion-proof NEMA-4x (aluminum, stainless steel or fiberglass are available as required). We never use painted enclosures or any galvanized metals.
- VFD: Variable-Frequency-Drive, a programmable AC motor drive, provides motor “soft-start” and optimum (minimum) operating speed, via a built-in speed-pot or up/down keys, to control fog output. Optimizes energy efficiency, audible motor noise and reduces maintenance. Also provides motor protection for overload, low voltage and short circuit, reduces vibration and heat.
- PLC based 18 I/O relay with 4-line display screen, real time digital clock and 100-hour battery back-up. Loaded with our exclusive control program, it provides optimum sequence control on pump station to avoid pump run-dry condition, show system run-time hour-meter and change oil message.
- User remote-control interface: connected to user�s main control panel for remote start and monitoring.
- HAND/OFF/AUTO 3-selector switch.
- 4 pilot lights shown system �Power On�, �Ready�, �Pump Run� and Fault� .
Protection features shut-down the pump station automatically whenever:
- No water supply or inlet water pressure is too low (lower than 12.5 psi)
- FD fault (because of overload or short circuit, etc.)
- Recycle timer: designed to continuously control the pump station On/Off in desired time ranges.
- Disconnect Switch interlocked with door open.
- E-Stop.
- Humidity Control ± 1% RH: humidistat with a remote humidity sensor & digital display provides On/Off relay to control the pump station based on pre-set value. Adjustable range is 0 to 100% RH.
- Temperature Control ± 1°F/C°: temperature controller with a remote thermal sensor provides On/Off relay to control the pump station based on pre-set value.