Adaptronic - Model NT 628 -Automated Modular Wiring Tester System
The NT 628 modular wiring tester with 512 test points for automated production lines optionally performs high voltage tests up to 1500 VDC and high current tests up to 2 ADC. The NT 628 modular wiring tester is specially designed for automated production lines. With 512 test points, the system guides connection, short-circuit, and component tests as well as optional high voltage tests up to 1500 VDC and high current tests up to 2 ADC. The system offers graphical test result visualization for intuitive fault localization and optional PROFINET remote control for Industry 4.0 integration. The modular design of the NT 628 can be flexibly expanded with four-wire measurement or insulation test up to 10 GΩ. The system meets current test standards. The included NT Control software allows for easy creation of test programs with a wide range of applicators for fault localization and automatic result logging.
NT 628
Metric
- Control software: NT Control
- Test of other components: Diodes, LEDs, Zener diodes, varistors, surge arresters
- Interfaces: Network, 2 x USB, pin number probe, connection option for red-green warning lamp, foot switch, test result indicator
- Dimensions/height: 150 mm
- Width: 450 mm
- Dimensions/depth: 395 mm
- Weight: ca. 8 kg
- Voltage (AC), input max.: 230 V
- Frequency, input min.: 50 Hz
- Frequency, input max.: 50 Hz
- Ambient temperature, operation min.: 10 °C
- Ambient temperature, operation max.: 40 °C
- Ambient temperature, storage min.: 10 °C
- Ambient temperature, storage max.: 60 °C
- Air humidity non-condensing min.: 30 %
- Air humidity non-condensing max.: 70 %
- Test voltage (DC) max.: 1500 W
- Test current (DC) max.: 2 A
- Test points, total max.: 512
- Continuity test via threshold identification min.: 0.001 Ω
- Continuity test via threshold identification max.: 10000000 kΩ
- Short-circuit test via threshold identification min.: 20 kΩ
- Short-circuit test via threshold identification max.: 5 MΩ
- Resistance measurement min.: 0.001 Ω
- Resistance measurement max.: 10000 MΩ
- Capacitance measurement min.: 10 nF
- Capacitance measurement max.: 0.02 F
- High voltage test (DC) max.: 1500 V
- DIO voltage max.: 24 V
Imperial
- Control software: NT Control
- Test of other components: Diodes, LEDs, Zener diodes, varistors, surge arresters
- Interfaces: Network, 2 x USB, pin number probe, connection option for red-green warning lamp, foot switch, test result indicator
- Weight: ca. 17.6 lb
- Voltage (AC), input max.: 230 V
- Frequency, input min.: 50 Hz
- Frequency, input max.: 50 Hz
- Ambient temperature, operation min.: 50 °F
- Ambient temperature, operation max.: 104 °F
- Ambient temperature, storage min.: 50 °F
- Ambient temperature, storage max.: 140 °F
- Air humidity non-condensing min.: 30 %
- Air humidity non-condensing max.: 70 %
- Test voltage (DC) max.: 1500 W
- Test current (DC) max.: 2 A
- Test points, total max.: 512
- Continuity test via threshold identification min.: 0.001 Ω
- Continuity test via threshold identification max.: 10000000 kΩ
- Short-circuit test via threshold identification min.: 20 kΩ
- Short-circuit test via threshold identification max.: 5 MΩ
- Resistance measurement min.: 0.001 Ω
- Resistance measurement max.: 10000 MΩ
- Capacitance measurement min.: 10 nF
- Capacitance measurement max.: 0.02 F
- High voltage test (DC) max.: 1500 V
- DIO voltage max.: 24 V