- Home
- Equipment
Refine by
Aquascat Environmental Equipment & Supplies
6 equipment items found
Manufactured by:Sigrist-Photometer AG based inEnnetbürgen, SWITZERLAND
In-line turbidity measurement for the water treatment. The AquaScat measures the turbidity of potable water according to IEC 27027, with the measurement carried out directly in the water. This reduces maintenance work to a minimum. The calibration is done with a checking unit that is installed when needed. Various customer wishes can be catered for with the different options for data ...
Manufactured by:Aquatec Group Ltd. based inBasingstoke, UNITED KINGDOM
As the flagship model in the AQUAscat® 1000 Range, the 1000R Research model sets the standard in acoustic measurement. It features up to four transducers, each capable of operating at distinct frequencies. This instrument excels in detecting sound scattered by sediment or other suspended materials, with an adjustable resolution range from 2.5 mm to 4 cm. This makes it ideal for a variety of ...
Manufactured by:Aquatec Group Ltd. based inBasingstoke, UNITED KINGDOM
The AQUAscat® 1000S represents a new generation of high frequency acoustic instrumentation. It has applications in sediment transport studies, including measurement of suspended sediment profiles, precision altimetry, dredge plumes and turbulence. The AQUAscat transmits pulses of high frequency sound on up to four transducers, each of which may operate at a different frequency. It measures ...
Manufactured by:Sigrist-Photometer AG based inEnnetbürgen, SWITZERLAND
The AquaScat measures turbidity of potable water according to IEC 27027 in a free-falling water stream. This contactless design eliminates window foiling and minimizes servicing which is especially of importance with the version HT for high turbidity. Calibration check is performed with a calibration unit with a glass reference to be mounted when performing the ...
Manufactured by:Sigrist-Photometer AG based inEnnetbürgen, SWITZERLAND
The AquaScat measures turbidity of potable water according to IEC 27027 and is specially designed for installations with highly gaseous water under pressure. Calibration check is performed with a calibration unit with a glass reference that is mounted when performing the ...
Manufactured by:Sigrist-Photometer AG based inEnnetbürgen, SWITZERLAND
The AquaScat measures turbidity of potable water according to IEC 27027 using 90+° scattered light detection in a free-falling water stream. This contactless design eliminates window foiling and minimizes servicing to a minimum. Calibration check is performed with a calibration unit that is either mounted to perform the check or that is already built in (depending on ...
