- Home
- Equipment
Refine by
Applications
- High quality gas sensor solutions for process control
- High quality gas sensing solutions for Agriculture industry
- High quality gas sensor solutions for landfill
- High quality gas sensor solutions for mining industry
- Electroluminescence and Photoluminescence Spectroscopy of a Phosphorescent Organic Light Emitting Diode (PhOLED)
- Confocal Raman and Photoluminescence Microscopy for Forensic Investigations
- Luminescence Thermometry with Upconversion Materials
- Determination of Chromaticity Coordinates and Bandgaps of III-V LEDs Using Electroluminescence Spectroscopy
- Observing Phase Transitions in a Halide Perovskite Using Temperature Dependent Photoluminescence Spectroscopy
- High-Resolution Raman & Photoluminescence Imaging of MoS2
- High quality gas sensor solutions for total organic carbon (TOC)
- Gas Detectors for Heating, Ventilation and Air Conditioning (HVAC) industry
- Gemstone Identification Using Raman Microscopy
- Kinetics of Photocatalysis Reactions Studied by Transient Absorption Spectroscopy
- Raman Spectroscopy as a Tool for Studying Polymer Phase Transitions
- Discrimination of Cooking Oils Using Raman Spectroscopy
- Emission Tail of Indium Phosphide Quantum Dots Investigated using the FS5 Spectrofluorometer
- Sn to Mn Energy Transfer Revealed using Time-Resolved Emission Spectroscopy (TRES)
- Identifying Thermally Activated Delayed Fluorescence (TADF) using an FS5 Spectrofluorometer
- Temperature Dependent Triplet States of Benzophenone; Spectral and Lifetime Measurements Utilising Transient Absorption Spectroscopy
- Fluorescence, Delayed Fluorescence and Phosphorescence Spectra of a TADF Emitter Measured using the FLS1000 with a VPL laser and Gated PMT Detector
- Photoluminescence Spectroscopy of Carbon Dots
- Measuring Ethanol Content in Hand Sanitiser Using Raman Spectroscopy
- Relative Quantum Yield of 2-Aminopyridine
- Ligand Binding Assays on the Basis of Fluorescence Anisotropy
- Identification of Microplastics Using Raman Spectroscopy
- Measuring Picosecond Fluorescence Lifetimes Using the FLS1000 Equipped with a Hybrid Photodetector
- Tuning the Photoluminescence of Graphene Oxide
- Photophysical Characterisation of Perovskite Quantum Dots
- SWCNT: Photogenerated Excited States in Solubillized Single-Wall Carbon Nanotubes; Transient Absorption and Oxygen Dependence of the Triplet
- Red-Edge Excitation Spectroscopy of Proteins with the FS5 Spectrofluorometer
- Whisky Analysis by Raman Spectroscopy
- Molecular Beacon Probe Fluorescent Detection of DNA
- Time-resolved Spectroscopy of Phosphorescent Oxygen Sensors in a Relevant in vitro Environment for Biomedical Applications
- Measuring Charge Carrier Lifetime in Halide Perovskite Using Time-Resolved Photoluminescence Spectroscopy
- Kinetics of Persistent Luminescence Phosphors
- Temperature Dependence of Phosphors via Photo-and Thermo-Luminescence
- Water Quality by Monitoring the Natural Organic Matter of Aquatic Systems
- Lipid-Protein Interactions Revealed by Fluorescence Spectroscopy
- Multimodal Raman, Photoluminescence & SHG Imaging of CVD Grown WSe2
- Pesticide Detection on Apple Skin Using SERS
- Plastics Identification Using ATR-FTIR Spectroscopy
- ATR-FTIR of Blood Serum Using a Heated ATR Accessory
- High quality gas sensor solutions for building and IAQ
Edinburgh Environmental Equipment & Supplies
27 equipment items found
Manufactured by:Edinburgh Instruments - TECHCOMP Group based in, UNITED KINGDOM
Ultra compact filter-based fluorescence lifetime spectrometer Short Lifetimes ranging from 25 ps to 10 μs MCS Option for lifetimes from 10 ns to 10 s Integrated electronics with repetition rates up to 100 MHz Ultra-fast blue or red sensitive single photon counting PMT for ultimate sensitivity Fully comprehensive data acquisition and ...
Manufactured by:Edinburgh Instruments - TECHCOMP Group based in, UNITED KINGDOM
AGILE® is a wavelength-tunable, high brightness supercontinuum laser providing picosecond pulses with variable kHz to MHz repetition rates. It features a broadband spectral output from 2000 nm and pulse repetition rates from 10 kHz to 1 MHz, making it the ideal light source for the majority of fluorescence lifetime applications. Using the Time-Correlated Single Photon Counting (TCSPC) technique, ...
Manufactured by:Edinburgh Instruments - TECHCOMP Group based in, UNITED KINGDOM
The EPL picosecond pulsed diode lasers are a family of high performance, cost effective excitation sources for fluorescence lifetime ...
Manufactured by:Edinburgh Instruments - TECHCOMP Group based in, UNITED KINGDOM
Sub-nanosecond pulsed LED light source Optimised for TCSPC Pre-set Repetition Frequencies from 20 KHz to 20 MHz External Trigger Facility Optimised Collimated Beam Spectrally Purified Output Built-In Drive ...
Manufactured by:Edinburgh Instruments - TECHCOMP Group based in, UNITED KINGDOM
Optimised for TCSPC; Pre-set Repetition Frequencies from 20 KHz to 20 MHz; Spectrally Purified Output; Optimised Collimated Beam; Drive Electronics Included; Fully Integrated, Compact ...
Manufactured by:Edinburgh Instruments - TECHCOMP Group based in, UNITED KINGDOM
The RM5 is a compact and fully automated Raman microscope for analytical and research purposes. The truly confocal design of the RM5 is unique to the market and offers uncompromised spectral resolution, spatial resolution, and ...
Manufactured by:Edinburgh Instruments - TECHCOMP Group based in, UNITED KINGDOM
The RMS1000 is an open architecture research grade confocal Raman microscope. It has been designed so it can be adapted to almost any modern, state-of-the-art Raman ...
Manufactured by:Edinburgh Instruments - TECHCOMP Group based in, UNITED KINGDOM
The IR5 is a high-performance benchtop Fourier Transform Infrared (FTIR) spectrometer from Edinburgh Instruments. The IR5 is the perfect choice for analytical and research applications such as polymer, semiconductor, and pharmaceutical samples, offering simple operation as well as fast and accurate results. IR absorption, transmission, reflectance, and infrared photoluminescence can all be ...
Manufactured by:Cervic Environment S.A based inIbi (Alicante), SPAIN
Economic multiwaste bin with an excellent value for money. Available for 2, 3 or 4 types of waste. Self-extinguishing certified (specific version). Collection system: inner ring bag holder or metal inner liner. An accessory to storage the cups stacked is available. Made of galvanized ...
Manufactured by:Edinburgh Instruments - TECHCOMP Group based in, UNITED KINGDOM
Optimised for MCS 14 Pre-Set pulse widths from 50 ns to 1 ms External trigger capability Adjust pulse width and repetition rate with input trigger pulse Operation in CW mode Spectrally Purified Output Compact plug-and-play ...
Manufactured by:Edinburgh Instruments - TECHCOMP Group based in, UNITED KINGDOM
Optimised for MCS; 14 Pre-Set pulse widths from 50 ns to 1 ms; External trigger capability; Adjust pulse width and repetition rate with input trigger pulse; Operation in CW mode; Spectrally Purified Output; Compact plug-and-play ...
Manufactured by:Edinburgh Instruments - TECHCOMP Group based in, UNITED KINGDOM
Optimised for TCSPC; Repetition rates up to 80 MHz; Standard and high-power operation mode; External trigger capability; Spectrally purified output; Compact plug-and-play design ...
Manufactured by:Edinburgh Analytical, Subdivision of Edinburgh Instruments Ltd based inLivingston, UNITED KINGDOM
A staple for any lab, the IA30 Fourier Transform Infrared (FTIR) Spectrometer is a high-performance benchtop instrument. Perfect for everyday analysis, it delivers fast, accurate IR measurements for all ...
Manufactured by:Edinburgh Instruments - TECHCOMP Group based in, UNITED KINGDOM
The DS5 UV-Vis Spectrophotometer is a high performance dual beam instrument that measures absorption and transmission as a function of wavelength and is suitable for many analytical applications where accuracy and precision measurements are key to your ...
Manufactured by:Edinburgh Sensors Ltd - TECHCOMP Group based inLivingston, UNITED KINGDOM
The IRgaskiT® infrared gas sensor is engineered for precise measurement of carbon dioxide concentrations, ensuring speedy and reliable integration across diverse systems. Its electronics module accommodates a variety of sensors via extendable cables, catering to the flexibility modern OEM instruments demand. Notably, it features a temperature compensated bench, facilitating single-button ...
Manufactured by:Edinburgh Instruments - TECHCOMP Group based in, UNITED KINGDOM
The LP980 spectrometer sets the standard for technical performance required in a premier research instrument, offering unsurpassed measurement capabilties across a broad range of chemical, physical and biological applications. ...
Manufactured by:Edinburgh Instruments - TECHCOMP Group based in, UNITED KINGDOM
The FLS1000 Spectrometer sets the standard in both steady state and time-resolved photoluminescence spectroscopy for both fundamental research and routine laboratory ...
Manufactured by:Edinburgh Instruments - TECHCOMP Group based in, UNITED KINGDOM
The FS5 Spectrofluorometer is designed to meet the highest measurement specifications in the research and analytical markets. To achieve optimal sensitivity, resolution, and acquisition speed, we select only the optimal performance photomultipliers in temperature stabilised housings, and utilise an optical design that includes plane, spherical, toroidal, ellipsoidal mirrors and optimised mirror ...
Manufactured by:Edinburgh Instruments - TECHCOMP Group based in, UNITED KINGDOM
Fastest TCSPC instrument on the market due to zero temporal dispersion Subtractive double‐monochromators result in zero temporal dispersion 5 ps – 10 μs lifetimes (detector and laser dependent) Extended NIR range – spectral coverage up to 1610 nm Compact footprint Multi-laser integration through two excitation ports; super‐continuum, Ti:Sapphire, and ...
Manufactured by:Edinburgh Analytical, Subdivision of Edinburgh Instruments Ltd based inLivingston, UNITED KINGDOM
A high sensitivity, user-friendly analytical fluorescence spectrometer. Designed and built to satisfy both routine work and ever-changing research requirements. ...
