- Home
- Companies
- CSS Electronics
- Products
- CSS Electronics - Model CL2000 - CAN ...
CSS Electronics - Model CL2000 -CAN Bus Logger & USB Interface
The CL2000 is a versatile CAN bus logger designed for standalone data logging and real-time USB streaming. Equipped with an 8 GB SD card, it can record CAN bus data with precise timestamping facilitated by its real-time clock, essential for accurate post-analysis. This device is particularly suited for vehicle fleet management, diagnostics, reverse engineering, and prototype testing due to its compact size and low cost. Its CAN interface supports various protocols like J1939, CANopen, NMEA, and OBD2, making it adaptable for numerous vehicles, including cars, trucks, and motorcycles. The CL2000 can also detect bit-rate automatically and be powered directly via a CAN connector or USB for configuration without additional power sources. Moreover, its support for cyclical logging ensures continuous data collection by overwriting old data when space runs out, providing a continuous logging solution. Its low power consumption allows it to be left connected without excessive drain on the vehicle’s battery.
The plug & play CL2000 CAN logger records CAN bus data to an 8 GB SD card and timestamps it with a real-time clock.
Further, the CL2000 can operate as a CAN bus interface for real-time USB streaming.
The CAN logger is ideal for vehicle fleet management (trucks, buses, harvesters, cars, ...), prototype field testing, diagnostics or reverse engineering.
GENERAL :
- Functionality : Data logger and real-time CAN interface
- LEDs : Logger status via three externally visible LEDs
- Firmware : Supports free firmware updates for adding features
- Software : Free executables for conversion to ASC/TRC [Windows/Linux]
- Free open source SavvyCAN software for streaming/analyzing CAN data + DBC decoding [Windows/Linux]
- The .INI config / .TXT log files can also simply be opened in text editors or scripts [Windows/Linux]
- Safety : CE, FCC, IC, RoHS certified
CAN BUS :
- Standard : Compliant with physical layer standard ISO 11898-2
- Identifiers : Compliant with CAN specifications 2.0A (11-Bit ID) and 2.0B (29-Bit ID)
- Bit Rate : Bit rates up to 1 Mbps (manually configured or automatically detected)
- Bit-rate auto-detection : Yes
- Protocol Support : Protocol independent (i.e. able to log CAN, J1939, CANopen, OBD2, ...)
- Filters : Advanced message filtering on four configurable channels
- Silent Mode : Yes (does not affect CAN-bus transmission)
- Fail-Safes : The device does not terminate the CAN-bus internally
DATA LOGGING :
- SD Card : Replaceable 8 GB SD card (optional 32 GB)
- Real-Time Clock : Yes (CAN messages are time-stamped with 1ms resolution)
- Control Signal : Logging state (enabled/disabled) can be changed run-time using a CAN-bus control message
- Heartbeat Signal : Supports heartbeat signal to periodically indicate logger status
- Cyclic Logging : Supports cyclic logging mode (oldest log file is deleted when file system is full)
- Down Sampling : CAN ID specific message down-sampling to reduce frequency of logged messages
- Transmit : Transmit up to 20 customized CAN bus messages (e.g. for OBD2). Full real-time transmit control via USB
- File System : Standard FAT file system
- Frames/Second : The CL2000 can log/stream ~800-1000 frames/sec without loss. For higher busloads, see the CANedge
- SUPPLY :
- Power via CAN connector : Power can be supplied from the DB9 CAN connector (log/stream) or via USB (data extraction)
- Via CAN connector (DB9) : Power supplied by the CAN bus (+7.0V to +32V DC)
- Protection : Reverse voltage protection on CAN-bus supply
- Transient voltage pulse protection on CAN-bus supply
- Power via USB : Power supplied by USB (+5.0V DC) for data extraction/configuration
- Consumption : The logger's power consumption is approximately 1 W
MECHANICAL :
- Enclosure : Robust, small enclosure
- Dimensions : 66.7 x 42.7 x 23.5 mm (L x W x H)
- Weight : 45 grams
- Connector : Standard D-sub 9 (DB9) connector (OBD2, J1939, "generic" adaptor optional)
- USB : Standard mini USB (B) connector for extracting data & streaming (cable not included)
- Temperature : Operating temperature: -20degC to +65degC
- Real-Time Clock : Built-in real-time-clock with calendar and battery backup
- Date and time information are added to log files
- Battery backup with more than two years of battery capacity
- IP Rating : IP Rating 40