SMC - Model ALCM-DT -Delta-Tubed Coriolis Mass Flow Meter
Smart Measurement’s ALCM-DT delta-tubed Coriolis mass flow meters use two tubes formed into a triangle shape, or delta, in a parallel arrangement. These delta tubes are vibrated at their resonant frequency by coils. Any mass flow passing through the tubes will generate Coriolis forces, which are created whenever a mass moves radially in a rotating system. These forces have opposite effects on the inlet and outlet sides, deforming each tube by a minor amount.
The excursion of the tubes in the Coriolis flow meter is detected by sensors located at the meter inlet and outlet, and is measured as a time delay, or phase shift. The phase shift between the rotational frequencies of both tubes is directly proportional to the mass flow rate.
The ALCM-DT delta-tubed Coriolis mass flow meter’s circuitry also makes it possible to determine conversions such as volumetric flow, percent concentration, and percent water-cut.
- Measurement of mass flow, density, temperature & volume flow
- Suitable for aggressive & contaminated media
- Measurement & display of percent water-cut for oil/water mixtures
- Excellent purging & sterilization capabilities thanks to dead spot-free construction
- High rotation frequency & well-balanced measuring tubes
- Operates at temperatures up to 575°F (300°C)
- Individual 8-point calibration including NIST-traceable report
- Optional EX protection
- Flow Range: 150~900,000 kg/hr
- Process Connections: Flanged (ANSI, DIN, Tri-Clamp®)
- Line Sizes: ½”~8”(15-200 mm)
- Process temperature: -76~662 °F (-60~350 °C) – Remote; -76~257 °F (-60~125 °C) – Integral
- Tube geometry: Delta-Tube
- Accuracy: ±0.5% of reading(std), 0.2% or 0.15% (opt)
- Repeatability: ±0.05% of reading
- Engineering Units (Mass): kg, lb, ton
- Display: Dot-Matrix LCD
- Engineering Units (Temp.): °C, °F
- Engineering Units: (Volume): m³, Liter, US Gallon, Imperial Gallon
- Zero Stability: 0.1% full-scale
- Zero Drift (%FS / °C): 0.005
- Max Working Pressure: 580 psig (4.0 MPa)
- Measuring Tube Mat’l: SS #316L
- Power Supply: 12~28 VDC, 86~260VAC,50~60Hz
- Housing Material: SS #304
- Outputs: 4-20 mA, frequency, pulse, RS485
- Power Consumption: Less than 12W
- Density Measuring Range: 43.7-81.2lb/ft³ (0.7~1.3 g/cc)
- Temperature Measuring Range: -76~662 °F (-60~350 °C) – Remote; -76~257 °F (-60~125 °C) – Integral
- Density Accuracy: ±0.06 b/ft³ (0.001 g/cc)
- Temperature Accuracy: ±0.5 °C