Bieler Lang GmbH
  1. Companies
  2. Bieler Lang GmbH
  3. Products
  4. Bieler-Lang - Model ExDetector HC 100 / ...

Bieler-LangModel ExDetector HC 100 / HC 100 K -Detector

SHARE

The ExDetector HC 100 sensor measures the current concentration of explosive gases and vapors. The ExDetector HC 100 is used to detect combustible gases and vapors in the measuring range from 0 to 100 % LEL. The measuring principle is based on catalytic combustion (pellistor). With this measuring principle, a large number of gases can be monitored, e.g. hydrogen and hydrocarbons (other gases on request).

Most popular related searches

The ExDetector HC 100 is a versatile sensor and is especially designed for use in Ex zone 1 and in overall safety systems classified according to SIL-1.

A type examination certificate for the measuring function according to RL 2014/34/EU is available. A measuring function certificate BAM 03 ATEX 0003 X is also available.

Variant: ExDetector HC 100 K

The ExDetector HC 100-T and HC 100-K sensor combination is specially designed for duct installation and has a remote transmitter.

This special combination is used to measure the current concentration of explosive gases and vapors in a pipeline network.

  • EG Type examination according to RL 2014/34/EU,
    Electrical safety of the equipment:
      II 2G
      Ex de [ib] IIC T6 Gb
      PTB 00 ATEX 1075
  • Measuring function:
    BAM 03 ATEX 0003 X
  • detectable gases:
    explosive gases and vapors

  • Measuring range 0 – 100 % UEG (lower explosion limit)
  • Measuring principle catalytic combustion (pellistor)
  • linear measuring signal 4 – 20 mA
  • One-man calibration – direct calibration at the detector (optional operating device)
  • 3-wire technology