Ultrasonic sensors for flow measurement in slight to heavily polluted media. Wedge shape for installation on channel wall or channel bottom.

Most popular related searches
  • Latest fourth-generation intelligent Doppler technology
  • Cost-effective pricing
  • Suitable for all channel cross sections
  • Easy to install without the need for additional constructions
  • Cables can be extended without any problems
  • Measurement in heavily polluted and abrasive media
  • Built-in pressure cell mechanically protected

KDA flow velocity sensors are suitable for continuous measurement of slight to heavily polluted media. The wedge-shaped sensors are designed for installation on either the channel wall or the channel bottom.

Combined with transmitter types such as PCM F and OCM F the result is a complete flow measurement system.

Typical applications for KDA wedge sensors

  • Wastewater treatment plants: intake, discharge, activated sludge tank intakes, return sludge, recirculation, surplus sludge, digester discharge and flocculant dosage
  • Permanent measurements on stormwater treatment facilities such as stormwater overflow tanks, rainwater sedimentation and retention tanks
  • Direct discharge control, infiltration (extraneous water) or leakage detection
  • Industrial wastewater networks
  • Measurement campaigns in channel networks
  • and many more

General

  • Measurement principle:
    • Doppler (flow velocity)
    • Piezo-resistive pressure measurement (level measurement)
  • Sensor types:
    • v-sensor with T-compensation
    • v-sensor with T-compensation and h measurement (hydrostatic)
  • Protection: IP 68
  • Ex-Approval:
    • II 2 G Ex ib IIB T4 gb (ATEX)
    • Ex ib IIB T4 Gb (IECEX)
  • Operating temperature:
    • -20 °C to +50 °C
    • -20 °C to +40 °C if using the sensors in Ex Zone 1
  • Storage temperature: -30 °C to +70 °C
  • Operating pressure: max. 4 bar (combi sensor with pressure cell max. 1 bar)
  • Cable lengths: 10/15/20/30/50/100 m pre-configured, can be extended upon request; a pressure compensation element is required if cables longer than 30 m are used with sensors featuring an integrated pressure measurement cell. The compensation element can be used also to connect the extension.
  • Cable types:
    • Combi sensor with pressure measurement:: LiYC11Y 2x1.5 + 1 x 2 x 0.34 + PA 1.5/2.5
    • Sensors without pressure measurement: LiYC11Y 2 x 1.5 + 1 x 2 x 0.34
  • Outside cable diameter:
    • Combi sensor with pressure measurement:: 9.75 mm ±0.25 mm
    • Sensors without pressure measurement: 8.4 mm ±0.25 mm
  • Sensor connection: Cable end pre-configured for connection to OCM F / FR, cable types "K" or "L"
  • Medium-contacting materials:
    • PVDF (wedge sensor body); stainless steel 1.4571 (ground plate); Polyurethane (cable sheath, screw joint and pipe sensor head)
    • Additionally for sensors with pressure measurement cell: Hastelloy© C276 (pressure cell); Viton; PA/PR (pressure cell gasket)
    • Optional: cable with FEP coating (sensors without pressure measurement only)

Flow velocity measurement

  • Measurement range: -600 cm/s to +600 cm/s
  • Measurement uncertainty: ±1 % of measurement range end value
  • Zero point drift: absolutely stable zero point
  • Beam angle: ±5 degrees

Level measurement – Pressure

  • Measurement range: 0 to 500 cm
  • Zero point drift: max. 0.75 % of final value (0 – 50 °C)
  • Measurement uncertainty: standing medium:
  • +/- 0.5 of final value (within a range of 0.05 – 3.5 m)

Temperature measurement

  • Measurement range: -20 °C to +60 °C
  • Measurement uncertainty: ±0.5 K