ProVu - Model PD6000 -Dual Line 6 Digit Process Meter
The ProVu meter boasts specifications and functionality that clearly make it one of the most advanced process meters available. Its dual-line 6-digit display (999,999), advanced signal input conditioning, function keys, Modbus RTU serial communications, and optional expansion modules are only a few of the features found on the ProVu PD6000.
FRONT PANEL DISPLAYPrecise, Accurate, and More Informative
ProVu`s large 0.6" upper display provides a highly accurate and precise 6-digit view of the process measurement. Its 24-bit A/D is accurate to ±0.03% of calibrated span ±1 count.
Configurable
The upper display can be programmed to indicate PV, maximum (peak), minimum (valley), alternating maximum/minimum, one of eight alarm set points, or Modbus input. The lower display can also be configured to display engineering units, set points, user defined legends, or simply turned off.
Optional SunBright Display Models
ProVu`s SunBright display models have an extraordinarily bright LED display. They are perfect for applications where the meter is in direct sunlight or in applications where visibility may be impaired by smoke, fog, dust, or distance. Option is available on all ProVu models.
Function Keys
There are three function keys available to the user. These keys can be programmed to trigger certain events (i.e. acknowledge alarms, reset max and/or min, disable/enable output relays, or hold current relay states), provide direct menu access points, and more.
Learn more about using the ProVu`s Function Keys by watching a video click here to watch.
Rugged
A unique front panel design makes the ProVu digital panel meter nearly impenetrable in typical applications. Here, the ProVu easily survives a direct hit on the display from a heavy 2" solid stainless steel ball dropped from eight feet.
Easy to Use
The user friendly dual-line display makes the ProVu easy to set up
& program. No jumpers to set for input selection. All setup & programming is done via the front panel. Three levels of password protection help maintain the reliability of the programming.
Dual-Scale Display Feature
The ProVu PD6000 has a rather unique and very flexible dual-scale capability; a second scaled display can represent the measured input in a different form (i.e. gallons & height). This is of particular value in level applications. Please see the examples shown below. Both displays are independently scaled and are based on the 4-20 mA input signal. Beyond level, this function has been used for pressure & force, current & power, feet & meters, GPM & CFM, and more.
- 0-20 mA, 4-20 mA, 0-5 V, 1-5 V, and ±10 V Inputs
- NEMA 4X, IP65 Front
- Universal 85-265 VAC or 12/24 VDC Input Power
- Large Dual-Line 6-Digit Display, 0.60" & 0.46"
- Dual-Scale for Level Applications – Single Input
- Sunlight Readable Display Models
- Isolated 24 VDC @ 200 mA Transmitter Power Supply
- Signal Input Conditioning for Flow & Round Horizontal Tanks
- Programmable Displays & Function Keys
- 32-Point, Square Root, or Exponential Linearization
- Multi-Pump Alternation Control
- 2 or 4 Relays + Isolated 4-20 mA Output Options
- External 4-Relay & Digital I/O Expansion Modules
- USB, RS-232, & RS-485 Serial Communication Options
- Tare Function
- Modbus® RTU Communication Protocol Standard
- On-Board Digital Input
- Configure, Monitor, and Datalog
General
- Display:Upper display: 0.60" (15 mm) high. Lower display: 0.46" (12 mm) high. Both are 6 digits (-99999 to 999999), red LEDs.
- Display Intensity: Eight intensity levels
- Display Update Rate: 5/second (200 ms)
- Overrange: Display flashes 999999
- Underrange: Display flashes -99999
- Display Assignment: The upper and lower displays may be assigned to PV1, PV2, PCT (percent), d r-u, d gross, d nt-g, max/min, alternate max & min, set points, units (lower display only), or Modbus input.
- Front Panel: NEMA 4X, IP65
- Programming Methods: Four front panel buttons, digital inputs, PC and MeterView Pro software, Modbus registers, or cloning using Copy function.
- F4 Digital Input Contacts: 3.3 VDC on contact. Connect normally open contacts across F4 to COM.
- F4 Digital Input Logic Levels: Logic High: 3 to 5 VDC
- Logic Low: 0 to 1.25 VDC
- Noise filter: Programmable from 2 to 199 (0 will disable filter)
- Filter Bypass: Programmable from 0.1 to 99.9% of calibrated span
- Recalibration: Calibrated at the factory. Recalibration is recommended at least every 12 months.
- Max/Min Display: Max / min readings reached by the process are stored until reset by the user or until power to the meter is turned off.
- Password: Three programmable passwords restrict modification of programmed settings.
- Non-Volatile Memory: All programmed settings are stored in nonvolatile memory for a minimum of ten years if power is lost.
- Power Options: 85-265 VAC 50/60 Hz, 90-265 VDC, 20 W max, or jumper selectable 12/24 VDC ±10%, 15 W max.
- Fuse: Required external fuse: UL Recognized, 5 A max, slow blow; up to 6 meters may share one 5 A fuse.
- Isolated Transmitter Power Supply: Terminals P+ & P-: 24 VDC ± 10%. 12/24 VDC powered models selectable for 24, 10, or 5 VDC supply (internal jumper J4).
- ProVu Series (PD6000):
- 85-265 VAC models rated @ 200 mA max, 12/24 VDC powered models
- rated @ 100 mA max, @ 50 mA max for 5 or 10 VDC supply.
- ProtEX-MAX (PD8 Series):
- All models transmitter supply rated @ 25mA max.
- Normal Mode Rejection: Greater than 60 dB at 50/60 Hz
- Isolation: 4 kV input/output-to-power line. 500 V input-to-output or output-to-P+ supply.
- Overvoltage Category: Installation Overvoltage Category II: Local level with smaller transient overvoltages than Installation Overvoltage Category III.
- Environmental:
- ProVu Series (PD6000):
- Operating temperature range: -40 to 65°C
- Storage temperature range: -40 to 85°C
- Relative humidity: 0 to 90% non-condensing
- ProtEX-MAX (PD8 Series):
- T6 Class operating temperature range Ta = -40 to 60°C
- T5 Class operating temperature range Ta = -40 to 65°C
- See LIM8 ProtEX-MAX instruction manual for additional details.
- Max Power Dissipation: PD8 Series: Maximum power dissipation limited to 15.1 W. See PD8 instruction manual for additional details.
- Connections: Removable screw terminal blocks accept 12 to 22 AWG wire, RJ45 for external relays, digital I/O, and serial communication adapters.
- Enclosure: 1/8 DIN, high impact plastic, UL 94V-0, color: black
- Mounting: 1/8 DIN panel cutout required: 3.622" x 1.772" (92 mm x 45 mm). Two panel mounting bracket assemblies are provided.
- Tightening Torque: Screw terminal connectors: 5 lb-in (0.56 Nm)
- Dimensions: 4.68" x 2.45" x 5.64" (119 mm x 62 mm x 143 mm) (W x H x D)
- Weight: 9.5 oz (269 g)
- UL File Number: UL & C-UL Listed. E160849; 508 Industrial Control Equipment.
- Warranty:3 years parts&labor
Process Input
- Inputs: Field selectable:0-20, 4-20 mA, ±10 VDC (0-5, 1-5, 0-10 V), Modbus PV (Slave)
- Accuracy: ±0.03% of calibrated span ±1 count, square root & programmable exponent accuracy range: 10-100% of calibrated span
- Temperature Drift: 0.005% of calibrated span/°C max from 0 to 65°C ambient, 0.01% of calibrated span/°C max from -40 to 0°C ambient
- Signal Input Conditioning: Linear, square root, programmable exponent, or round horizontal tank volume calculation.
- Multi-Point Linearization: 2 to 32 points for PV or PV1. 2 to 8 points for PV2 (Dual-Scale Level feature)
- Programmable Exponent: 1.0001 to 2.9999
- Low-Flow Cutoff: 0-999999 (0 disables cutoff function)
- Decimal Point: Up to five decimal places or none: d.ddddd, dd.dddd,ddd.ddd, dddd.dd, ddddd.d, or dddddd.
- Calibration Range: 4-20 mA: minimum span input 1 & input 2: 0.15 mA. ±10 V: minimum span input 1 & 2: 0.10 V. An Error message will appear if input 1 and input 2 signals are too close together.
- Input Impedance: Voltage ranges: greater than 1 MΩ. Current ranges: 50 - 100 Ω (depending on resettable fuse impedance).
- Input Overload:Current input protected by resettable fuse, 30 VDC max.
Relays
Rating:2 or 4 SPDT (Form C) internal and/or 4 SPST (Form A) external; rated 3 A @ 30 VDC and 125/250 VAC resistive load; 1/14 HP (≈ 50 watts) @ 125/250 VAC for inductive loads such as contactors, solenoids, etc.
Noise Suppression: Noise suppression is recommended for each relay contact switching inductive loads.
Deadband: 0-100% of span, user programmable
High or Low Alarm: User may program any alarm for high or low trip point. Unused alarm LEDs and relays may be disabled (turned off).
Relay Operation: automatic (non-latching), latching (requires manual acknowledge), sampling (based on time), pump alternation control (2 to 8 relays), Off (disable unused relays and enable interlock feature, manual on/off control mode).
Relay Reset: User selectable via front panel buttons or digital inputs.
1. Automatic reset only (non-latching), when input passes the reset point.
2. Automatic + manual reset at any time (non-latching).
3. Manual reset only, at any time (latching).
4. Manual reset only after alarm condition has cleared (latching).
Note: Front panel button or digital input may be assigned to acknowledge relays programmed for manual reset. Time Delay: 0 to 999.9 seconds, on & off relay time delays. Programmable and independent for each relay. Fail-Safe Operation: Programmable and independent for each relay. Note: Relay coil is energized in non-alarm condition. In case of power failure, relay will go to alarm state. Auto Initialization:When power is applied to the meter, relays will reflect the state of the input to the meter.
Serial Communications
- Protocol:Modbus® RTU
- Meter Address/Slave ID: 1 - 247
- Baud Rate: 300 - 19,200 bps
- Transmit Time Delay: Programmable between 0 and 199 ms or transmitter always on for RS-422 communication
- Data: 8 bit (1 start bit, 1 or 2 stop bits)
- Parity: Even, odd, or none with 1 or 2 stop bits
- Byte-to-Byte Timeout: 0.01 - 2.54 seconds
- Turn Around Delay: Less than 2 ms (fixed)
- Note: Refer to the PD6000/PD7000 Modbus Register Tables for details
Isolated 4-20 mA Transmitter Output
- Output Source:Process variable (PV), max, min, set points 1-8, manual control setting, or Modbus input
- Scaling Range: 1.000 to 23.000 mA for any display range
- Calibration: Factory calibrated: 4.000 to 20.000 = 4-20 mA output
- Analog Output Programming: 23.000 mA maximum for all parameters:
- Overrange, underrange, max, min, and break
- Accuracy: ± 0.1% of span ± 0.004 mA
- Temperature Drift: 0.4 µA/°C max from 0 to 65°C ambient, 0.8 µA/°C max from -40 to 0°C ambient
- Note: Analog output drift is separate from input drift.
- Isolated Transmitter Power Supply: Terminals I+ & R: 24 VDC ±10% . May be used to power the 4-20 mA output or other devices.
- ProVu Series (PD6000): All models rated @ 40 mA max.
- ProtEX-MAX (PD8 Series): All models @ 25 mA max.
Digital I/O Expansion Module
- Channels:4 digital inputs & 4 digital outputs per module
- System: Up to 2 modules for a total of 8 inputs & 8 outputs
- Digital Input Logic: High: 3 to 5 VDC Low: 0 to 1.25 VDC
- Digital Output Logic: High: 3.1 to 3.3 VDC Low: 0 to 0.4 VDC
- Source Current: 10 mA maximum
- Sink Current: 1.5 mA minimum
- +5 V Terminal: To be used as pull-up for digital inputs only