- Home
- Companies
- Emco Controls A/S
- Products
- EMCO - Model ISB/1 EP - Orifice Plate
EMCO - Model ISB/1 EP -Orifice Plate
The EMCO Orifice Plate is used as a primary element in flow measurement of liquid, gas and steam applications based on the differential pressure principle. According to this working principle, the orifice plate creates a flow restriction in the pipeline to allow measurement of the resulting pressure drop and flow rate. Our orifice plates have been tested and tried for over 50 years and measure up to the highest industry and compliance standards. The Orifice Plate Series ISB/1 EP is especially designed for installations with limited space due to the flow conditioning effect created by the 5 hole design. The design therefore combines a traditional single bore orifice plate with a flow conditioner which can reduce the flow meter from 20 times inner pipe diameter to 5 times inner pipe diameter upstream in a straight pipe run.
Construction
Design and calculation standards: ISO 5167, ASME MFC-3M, ASME
Sizes: 2” - 24" according to ANSI B 16.36
Pressure rating: 300 - 600 lbs RF
Plate thickness: 3 - 16 mm depending on plate size
β (d/D): 0,5 - 0,6
Material: AISI 316, 22Cr Duplex 25Cr Duplex, Monel, 6Mo Hastelloy, titanium and others on request
Mounting style: Between raised face flanges according To ANSI B16.36 or DIN 19214, other standards on request
Orifice plate shapes: Square edge
Handle: With name plate in AISI 316 with the following inscription : TAG no., serial no., pressure rating, inner pipe diameter., beta equivalent, material.
Technical Data
Accuracy: +/- 1 %
Pressure loss: Depending on β, for β equal to 0,6 : ca. 60 % of the differential pressure measured
Limits for Reynolds No: Re > 5000
Allowable differential pressure: 2,5 bar
Limits for Reynolds No: Re > 1260 x β^2 D according to ISO 5167 2000 < Re < 10^8 according to ASME MFC-3M