Most popular related searches
engine emissions
exhaust gas analysis system
engine emissions analysis
engine emissions monitoring
sample handling system
heated sampling system
NO/NO2/NOx
exhaust gas analysis
gas analysis system
analysis system
- Measurement of THC, NO, NO2, NOx, CO, CO2, O2 and NH3
- Designed to measure emissions from all combustion engines regardless of fuel type
STATE-OF-THE-ART SYSTEM DESIGN:
- Modular design with interchangeable bench components
- User-friendly networking technology for analyzer control & host interface (Ethernet-TCP/IP)
- Internal architecture designed for easy access and maintenance
- Wide measuring range for many applications
- Remote control of system and components
- Easy to operate software
- Modular design for maximum system flexibility
- Complies to latest emission regulations
- Positive pressure sample
- Total solutions with full turnkey capabilities
- Unique: SS filter integrated to the primary heated sample line
- Unique optical technology for precise, highly accurate and simultaneous measurement of CO, CO2, NO/NOx, THC, O2, N2O, SO2, NH3 and CH4
- Designed to measure emissions from all combustion engines, regardless of fuel type
- Separate, mobile sample handling system with built-in sample pump or full integration in the main control unit
- External or built-in operating PC with dedicated 40 CFR Part 1065 software package
- Engine manufacturers and testing companies in the automotive, heavy duty, aviation, marine, rail transport sectors, etc.
- Certification Bodies
- Universities and Research Centres
- General engine and/or vehicle performance test
- Development of clean engines
- Optimisation and evaluation of exhaust gas after-treatment devices
- Catalyst system performance evaluation (pre and post cat measurements)
- SCR, raw, diluted exhaust and EGR
- Enclosure: 19” rack cabinet
- Dimension (mm): 1360x600x800 (LxWxD)
- Weight: 150kg / 330lbs (includes all internal components)
- Operating temperature: 5°C to 45°C
- Relative Humidity: max 90%
- Power supply: 230V/50-60Hz or 115V/60Hz
- Nominal power consumption: 3.2 kVA
- Sample dimensions (mm): 1000x540x420 (LxWxD)
- Sample weight: 78kg / 154lbs (includes all internal components)
- Utilities:
- Compressed air for back purge
- H2/He (40/60%) for HFID
- N2 (100%) for zero gas
- O2 (100% ) for CLD
- Span gases function of analyzers
All our EGAS range of products is fully compliant to the worldwide vehicle Emission Standards, including the implementation of the Rule CFR 40 -1065, Diesel 2007/2010 Euro V & Euro VI, the EEM (Engine Emission Monitoring).