142 products found
ENVEA Products
-
Process - Flow Measurement
-
ENVEA - Model DensFlow HP - Flow Measurement for Dense-Phase Conveying
Continuous flow measurement of powder or granules in high pressure dense-phase conveying. Designed to measure solid flows during pneumatic dense phase transport. The sensor measures density and speed. ...
-
ENVEA - Model SlideControl 2.0 - Flow Monitoring on Air Slides
Microwave sensor for contactless of material flow in air slides. Easy to install, it gives trending information by 4… 20mA ...
-
ENVEA - Model PicoFlow - Continuous Flow Measurement Instruments
Perfectly adapted for control and regulation of reagent in flue gas treatment and transport lines with very low material ...
-
ENVEA - Model DensFlow - Flow Measurement for Dense-Phase Conveying
Continuous solids mass flow measurement in dense-stream conveying and high levels of throughput. Designed to measure solid flows during pneumatic dense phase transport. The sensor measures density and speed. No wear thanks to the ceramic inner ...
-
ENVEA - Model MaxxFlow HTC - Massflow Measurement for Dry Bulk Solids
Contact-less and maintenance free measurement of high mass flow rates of dry bulk solids independent of pipe run. Electromagnetic flowmeter, designed to measure bulk material flows up to 300 t/h. The meter has no mechanical parts in the flow, is 100 % dustproof and erosion free thanks to the ceramic inner pipe: arbitrary mounting position (inclined/free fall), low headroom required, easy to ...
-
ENVEA - Model SolidFlow 2.0 - Dry Bulk Solids Measurement Instruments
Continuous mass flow measurement of all types of dust, powder and granules in free fall and pneumatic conveying. Microwave sensor for on-line mass flow measurement of solids up to 20 ...
-
ENVEA - Model DensFlow - Flow Metering in Dense-Stream
The measuring system for continuous flow metering in dense-stream conveying and high levels of throughput. Reliable flow metering in pneumatic dense-stream. Unlimited throughput volumes can be measured. optionally pressure-resistant up to 25 bar. Installation creates no obstacle in the profile, hence no dead spots in which residue can form. Measurement independent of the flow speed of the material. Simple retrofitting. Maintenance-free. Contactless ...
-
ENVEA - Model AirFlow-P - Volume Flow Measurement
Measurement of the volume flow, especially in dusty applications. Easy installation on existing ducts, no Venturi or similar conversions are required. Can be used in environments with low dust loads or in harsh conditions with e. g. high dust loads. AirFlow P is the perfect measuring device for volumetric flow measurement at positions where differential pressure measurements can not be used due to excessive dust loading or where duct conversions are not ...
-
Process - Flow Detection
-
ENVEA - Model FlowJam-S - Material Flow Monitoring Detector
Microwave sensor for contactless monitoring of material flows with trend ...
-
ENVEA - Model FlowJam-A - Material Flow Monitoring on Flexible Hoses
Material flow monitoring on flexible hose lines for small quantities. FlowJam A is a sensor which has been specially developed for monitoring the flow of solids conveyed by hose lines. The system can be applied to hose lines made of non-conducting materials such as plastic or rubber with external diameters of between 2 and 10 ...
-
ENVEA - Model FlowJam Plus - Material Flow Monitor with Blockage Detector
Material flow monitoring with Flow/No Flow information plus additional “Detection of blockage” or “Material flow interruption” function ...
-
ENVEA - Model FlowJam - Continuous Material Flow Detection (Flow / NoFlow)
Microwave sensor for contactless monitoring of material flow and detection of material blockage. The system operates with no contact in a process in which the material movement is detected by using the Doppler effect. The FlowJam is a process-secure device, since the microwave technology used can penetrate material coating on the sensor and reliably detect the material movement behind it. If container walls, housings or pipelines are not metal, it is ...
-
ENVEA - Model FlowJam-T - Powder Flow Monitoring In Flexible Pipelines
FlowJam T is a sensor that has been specially developed for monitoring the flow of solids that are conveyed through thin pipelines. The sensor can be used for tubes made of electrically non-conductive material, such as plastic or rubber, with outside diameters between 4 and 25 mm. The sensor is mounted around the tube for ...
-
ENVEA - Model FlowJam - Continuous Material Flow Detection (Flow / NoFlow) Application
System features: Areas of use: The FlowJam detects streams of solids of all types by monitoring material movement. It distinguishes between the following switch conditions: Material flow, Material blockage / standstill or empty pipe. The FlowJam is completely insensitive to coatings on the sensor window and measures straight through all non-metallic pipelines. No contact with the material is required. The distance for this can be up to 2 metres. The ...
-
Process - Moisture measurement
-
ENVEA - Model M-Sens 3 - Moisture Measurement with Temperature Display and Material Flow Monitoring
Microwave sensor for continuous moisture measurement in dry bulk solids, with flow detection and process temperature ...
-
ENVEA - Model M-Sens WR - Online Residual Moisture Measurement
Sensor for continuous moisture measurement in dry bulk solids. Sensors for continuous moisture measurement and installation on conveyor belts, screw feeder or hoppers. Two types of sensor-technology to cover a wide range of applications. Both sensors penetrate the product for most reliable ...
-
ENVEA - Model M-Sens 2 - Online Humidity Measurement Sensor
Microwave sensor for continuous moisture measurement in dry bulk solids. Sensors for continuous moisture measurement and installation on conveyor belts, screw feeder or hoppers. Two types of sensor-technology to cover a wide range of applications. Both sensors penetrate the product for most reliable ...
-
ENVEA - Model M-Sens2 - Online Moisture Measurement Microwave Sensor
The microwave sensor for continuous humidity measurement in dry bulk solids. Simple retrofitting for measurement in container outlets, conveyor screws, on conveyor belts, slides ...
-
ENVEA - Model M-Sens 2 FD - Online Moisture Measurement with Flow Detection
The microwave sensor for continuous moisture measurement including flow detection for solids. Simple retrofitting for measurement in container outlets, conveyor screws, on conveyor belts, slides ...
-
Process - Velocity measurement
-
ENVEA - Model SpeedFlow 2.0 - Pipe Velocity Measurement, Material Transport
Velocity measurement in full cross-section version. Continuous velocity measurement in tube version for careful material transport. Measures in full ...
-
ENVEA - Model SpeedFlow 2.0 - Velocity Measurement for Solids
Continous speed measurement for solids usable in free fall and pneumatics. Especially designed for continuous measurement of velocity of solids and particles such as granulates, powders and dusts, which are transported in free fall or in pneumatic transport. Uses triboelectric correlation ...
-
Process - Level Monitoring
-
ENVEA - Model ProGap 2.0 - Point Level Monitoring
Microwave barrier for contactless detection of dry bulk solids in containers, pipes or chutes. Reliable fill level and limit ...
-
ENVEA - Model ProGap 2.0-BS - Point Level Monitoring
Microwave barrier for contactless detection of dry bulk solids with ...
-
ENVEA - Model Nico 120 - Continuous Level Monitoring
Radar sensor for measuring the level in silos and containers. Available for silos up to 120 m height. Can be used for a wide variety of materials, regardless of the size or composition of the ...
-
ENVEA - Model ProGap 2.0-BS - Bulk Solids Level Detection
Microwave barrier for the contactless detection of dry bulk solids in containers, piping or ...
-
Process - Emissions Gas Monitors
-
ENVEA - Model LAS 300 RK - Extractive TDLAS Gas Analyzer
High precision measurements of selective compounds such as: HF, HCl, NH3, O2, NO, CO and H2O. Other gases on request. Ideal for applications which require reliable and specific measurements, this gas monitor is suitable for monitoring ppb and ppm concentrations in emissions, ambient. Air or process monitoring. It uses rapid laser tuning and direct absorption spectroscopy to achieve very stable ...
-
ENVEA - Model LAS 300 XD - In-Situ Cross-Duct TDLAS Analyzer
TDL monitor for in-situ non-invasive measurement of NH3 & H2O, HCl & H2O, HF as well as low or high concentrations of CO and O2 in process or CEMS applications. The Tunable Diode Laser Spectroscopy (TDLS) is the perfect technology to use when you are looking for a selective measurement and a fast response time on some gas components as NH3, HCL, HF or even O2 when conditions are too rough for standard O2 Zirconia In-Situ ...
-
ENVEA - Model MIR 9000e - NDIR-GFC multigas analyzer
Eco-designed, smart & connected multigas monitor, the MIR 9000e is a must have for measuring combustion exhaust gases from boiler, industrial furnaces and Process Applications. It offers increased accuracy and robust operation, along with ultra low power consumption & economical, reduced maintenance. - Capable of measuring continuously up to 8 components (NOx, SO2, CO, CO2, CH4, N2O, O2 and residual H2O) incl. greenhouse gases. - Ultra-Compact 19" - 3U ...
-
Process - Gas Monitors - NO
-
ENVEA - Model TOPAZE 32M - Heated CLD NOx Analyzer
Single reaction chamber version for the monitoring of NO or NOx, or dual chamber for NO, NOx and NO2 measurements. Exist in 2 different versions: TOPAZE 52M-S : NO or NOx monitoring. TOPAZE 52M-D : NO-NOx and NO2 simultaneous ...
-
Process - Filter Performance Monitors
-
ENVEA - Model PCME LEAK LOCATE 662 - Filter Performance Monitors
Controller based filter dust leak monitor (0-100%) for filter emissions monitoring after bag houses, cartridge filters, cyclones ...
-
ENVEA - Model PCME LEAK LOCATE 320 - ElectroDynamic Multi-chamber Filter Performance Monitor
Controller based filter dust leak monitor (0-100%) for filter emissions monitoring after bag houses, cartridge filters, cyclones ...
-
Process - Broken Bag Detection
-
ENVEA - Model PCME STACK 990 - ElectroDynamic Approved Particulate CEM
QAL1 TÜV approved particulate monitor providing high quality emission measurement for low dust concentrations from dry industrial processes including Baghouses and Cartridge ...
-
ENVEA - Model PCME DUST ALARM 40 - ElectroDynamic Bag Filters Failure Detectors
Controller based Gross filter failure detector. Detects significant increases in particulate loading providing warnings of filter media degradation in baghouses and cartridge ...
-
ENVEA - Model Dusty C - Compact Sensor for Broken Bag Detection
Continuously monitors particulate flow for signs of filter damage or broken filter bags. Compact and cost effective. The Dusty C has been specially developed to monitor clean sides after filters with high reliability and without time delay for filter breaks. It can be used in metallic ducts in which dust particles will be detected in the gas flow. Its area of application begins at dust levels of 0.1 ...
-
ENVEA - Model Dusty - Broken Bag Detection
Cost effective broken bag detection. A simple solution to identify failure of a fabric filter baghouse, cartridge filters or cyclones. Ideally suited to applications from 0.1 mg/m3, it provides an immediate alarm in case of a filter ...
-
Process - Leak Monitors
-
ENVEA - Model PCME LEAK ALERT 65-02 - ElectroDynamic Filter Dust/Leak Monitor
Controller based filter dust leak monitor (0-100%) for filter emissions monitoring after bag houses, cartridge filters, cyclones etc. where performance approvals are not ...
-
ENVEA - Model PCME LEAK ALERT 73 - Dust Filter Leak Monitors
Stand alone filter dust leak monitor (0-100%) for filter emissions monitoring after baghouses, cartridge filters, cyclones etc. where performance approvals are not ...
-
ENVEA - Model PCME LEAK ALERT 75 - ElectroDynamic Filter Dust/Leak Monitor
Stand alone TÜV approved filter dust leak monitor suited to the monitoring of filter emissions (0-100%) after bag houses, cartridge filters, cyclones ...
-
ENVEA - Model PCME LEAK ALERT 80 - ElectroDynamic Filter Dust Leak Monitor
Stand alone TÜV approved filter dust monitor suited to the measurement of filter emissions after bag houses, cartridge filters, cyclones ...
-
Process - Dust Monitors
-
ENVEA - Model PCME DM 170 - Light Scatter Particulate Emissions Monitor
The DM 170 is designed to comply with the TÜV suitability testing scheme to EN 15267 and for measuring dust concentrations in a wide range of industrial ...
-
ENVEA - Model PCME QAL 260 - MCERTS Approved Back Scatter Particulate CEM
MCERTS QAL1 approved, stand alone or multi-sensor Particulate CEM providing high quality emission measurement for low dust concentrations from dry industrial ...
-
ENVEA - Model PCME VIEW 580 - Dynamic Opacity Dust Monitor
Stand alone Cross Stack optical dust monitor suitable for measuring emissions after electrostatic precipitators and stacks without filtration systems. Used for emissions measurement (mg/m³) after electrostatic precipitators and baghouses or Process control applications. Advanced sensor design includes automatic drift (zero and span) ...
-
ENVEA - Model PCME VIEW 273 - ElectroDynamic Dust Monitor
Multi-sensor dust monitor for indicative emissions trending in industrial stacks after bag filters, cartridge filters, cyclones and process driers, where regulatory approvals are not necessary. Advanced Probe Electrification featuring long term data logging for process trend analysis and ...
-
ENVEA - Model PCME VIEW 820 - ElectroDynamic Dust Monitor
Certified Multi-sensor dust monitor – category 1 under ATEX / IECEx – for indicative emissions trending and measurement in hazardous zone and in dry processess with elevated pressures. Advanced Probe Electrification featuring long term data logging for process trend analysis and ...
-
ENVEA - Model PCME VIEW 800 - ElectroDynamic Multi-Sensor Dust Monitor
Multi-Sensor Dust Monitor certified to category 1 under ATEX / IECEx designed for indicative emissions trending and measurement in challenging hazardous zone. Advanced Probe Electrification technology, perfectly adapted for particulate monitoring after bag filters, cartridge filters, cyclones and process driers, where regulatory approvals are not ...
-
ENVEA - Model PCME VIEW 370 - ElectroDynamic Dust Monitor
Multi-sensor dust monitor designed for high quality emission measurement in industrial stacks after bag filters, cartridge filters, cyclones and process driers. Advanced Probe Electrification Multi-sensor dust monitor designed for high quality emission measurement in industrial stacks where regulatory approvals are not ...
-
ENVEA - Model ProSens - Dust Measurement After Filters
Provides continuous measurement values for dust concentration as a trend signal or absolute values. The ProSens has been specially developed to carry out reliable dust measurement on clean sides after filters. The measuring device provides measurement values for dust concentration, either as a trend signal or as absolute values (after calibration) for emission ...
-
ENVEA - Model Dusty - Filter Damage Monitoring
Dusty is a filter monitor that works on a triboelectric ...
-
ENVEA - Model ProSens - Dust Detection
The ProSens was specially developed to carry out reliable dust measurement on clean sides after ...
-
ENVEA - Model PCME LEAK LOCATE 320 - Filter Damage and Leak Monitoring
Electrodynamic filter damage and leakage monitoring of industrial multi chamber filter systems: proactive multi chamber filter monitoring, identification of upcoming filter damages, identification of the filter chamber affected by filter breakage, reduction of material-, downtime- and maintenance costs, flue-gas temperatures up to 150 °C (optional 250 °C), for dry applications, 4 sensors inclusive, expandable up to 32 sensors, digital inputs and ...
-
ENVEA - Model PCME DM 170 - Backscatter Dust Measurement
DM 170 is a backscatter particulate measurement sensor for measuring dust ...
-
Process - Particle Size Monitoring
-
ENVEA - Model Paddy - Particle Size Monitoring
Paddy has been developed to supply a trending information of pulverization. It measures changes in particle size for instance to detect screen breaks. Paddy is insensitive against contaminations and works without a ...
-
Process - Mercury Instruments
-
ENVEA - Model VM-3000 - Mercury Vapor Monitor for Continuous Measurements in Air and Other Gases
Perfectly adapted for continuous Air Quality monitoring, laboratories, environmental surveillance, quality control, etc. The VM-3000 Mercury Vapor Monitor measures continuously the Hg concentration in air and other gases. It is used for laboratory applications as well as installed at places where mercury has to be monitored. It is a great tool for many different fields of applications in scientific research or the industrial ...
-
ENVEA - Model PA-2 / PA2 - Gold Mercury Analyzer for Water and Aqueous Solutions in Process Applications
The mercury analyzer PA-2 is used for continuous monitoring of mercury concentrations in industrial processes. The PA-2 was specially designed for process analysis and operation under harsh industrial condition. The system comes with either the VM-3000 or the UT-3000 photometer to meet different requirements regarding accuracy and sensitivity of ...
-
Emissions & Process - Gas Monitors
-
ENVEA - Model Graphite 52M - VOC - THC - CH4 Heated Flame Ionization Detection (FID) Analyzer
One of the sole QAL 1 certified FID analyzers on the market, also available in a transportable version for the measurement of: THC or simultaneous THC, nmHC & CH4. Perfactly suited to continuously monitor COV removal systems efficiency in all type of ...
-
ENVEA - Model MIR IS - In-Situ Close-Coupled Multi-Gas Analyzer
A complete “all in one compact” system, for multi-gas measurements, based on the field-proven MIR 9000 analyzer and on-board SEC sampling ...
-
ENVEA - Model SM-4 - Total Mercury Emissions Monitor in Stack Flue Gases
Continuous, accurate and reliable measurement of total mercury emissions, even in very low concentrations and within complex matrices (SO2, NOx, HCl, etc.). With over 20 years experience, Mercury Instruments (part of ENVEA Group) were the first to develop mercury monitors and mercury analyzers using a dry thermocatalytic method instead of wet chemistry. The SM-4 Mercury Monitor is QAL1 certified and is ready to meet future regulatory requirements ...
-
ENVEA - Model MIR 9000 CLD - Multi-Gas Analyzer Infra-Red GFC (CLD-Chemiluminescence Option)
A unique multi-gaz analyzer for the continuous monitoring of: NO, NO2, NOx, N2O, CO, CO2, SO2, HCl, HF, CH4, TOC and O2 in process applications and for stack emission compliance. Optional measurement of NOX by ...
-
Emissions - Particulate CEMS
-
ENVEA - Model PCME STACK 710 - Opacity Approved Particulate CEM
QAL1 approved particulate CEM which meets US EPA PS-1 requirements for Opacity monitoring from combustion stacks. Robust multi corner cube reflector provides truer reflection of transmitted light compared to traditional “mirror type” reflectors providing greater confidence in measurement. ...
-
ENVEA - Model PCME STACK 602 - Dynamic opacity Approved Particulate CEM
TÜV approved DynamicOpacity™ particulate monitor for emission measurement of dust from large dry industrial processes including Baghouses and Electrostatic ...
-
ENVEA - Model PCME STACK 980 - ElectroDynamic Approved Particulate CEM
MCERTS EN 15859 Filter Dust Approved Particulate monitoring system providing high quality emission measurement for low dust concentrations from dry industrial processes including Baghouses and Cartridge ...
-
ENVEA - Model PCME QAL 991 - ElectroDynamic Approved Particulate CEM
QAL1 approved particulate CEM providing high quality emission measurement for low dust concentrations from dry industrial processes including Baghouses and Cartridge ...
-
ENVEA - Model PCME QAL 360 - QAL1 Approved Back Scatters Particulate CEM
TUV QAL1 and MCERTS Approved, Stand alone or networked system option Particulate CEM providing high quality emission measurement for dust concentrations from industrial processes. Having a 0–7.5 mg/m³ certification range, the QAL 360 sensor can be used at low or high dust levels meeting the tightened minimum emission limit value of 5 mg/m³ for Large Combustion Plant specified in the Industrial Emissions Directive. ...
-
ENVEA - Model PCME STACK 181 - PS11 Capable Forward Scatter Particulate CEM
US EPA PS11 compliant ProScatter™ particulate CEM providing high quality emission measurement for low dust concentrations from industrial processes. Utilising the patented ProScatterTM Forward Scatter measurement technique for measuring particulate concentration levels, typically between 0.06 mg/m3 to 300 mg/m3, this measurement technique offers improved levels of performance which make the PCME STACK 181 very suitable for use as a PM CPMS or PM ...
-
ENVEA - Model PCME QAL 181 QAL1 - Forward Scatter Particulate CEM
QAL1 Approved ProScatter particulate CEM providing high quality emission measurement of low dust concentrations from dry industrial ...
-
ENVEA - Model PCME STACK 181 WS - Particulate CEM for Wet Gas Stream
US EPA PS11 capable ProScatter™ particulate CEM for the extractive sampling and measurement of particulate in saturated wet gas ...
-
ENVEA - Model PCME QAL 182 WS - Particulate CEM for Wet Gas Streams
QAL1 approved ProScatterTM particulate CEM for the extractive sampling and measurement of particulate in saturated wet gas streams. Continuous Particulate Monitoring for saturated wet stack applications typically found after wet scrubbers, wet electrostatic precipitators and wet flue gas desulphurisation ...
-
Emissions - Mercury Instruments
-
ENVEA - Model Mercury Instruments SM-3 - Stack Gas Monitor
The SM-3 mercury analyzer measures continuously the elemental, bound and ionic mercury in stack fluegas. The operating principle of the SM-3 is based on a completely new technique: mercury compounds cracking and the reduction of ionic mercury contained in stack gas is performed applying the thermocatalytic method. Wet chemical sample gas treatment using reagents and bubblers is avoided. Maintenance and servicing of the SM-3 are therefore extremely ...
-
ENVEA - Model SM-4 Mobile - Modular Mercury Stack Gas Monitor QAL 1 Certified
Technically identical to the SM-4, this device is ideal for mercury determination at varying sites. The SM-4 Mobile by Mercury Instruments has been developed on the basis of the well proven SM-4 mercury stack gas monitor. Its measurement principle and technique, its thermocatalytic reactor, the detector and the sample probe are identical with those of the stationary ...
-
ENVEA - Model SM-5 Hg CEMS - Total Mercury Emissions Monitor in Stack Flue Gases
Beneficiary of over 20 years of experience in mercury measurement, the new SM-5 CEMS Hg analyzer is designed to provide extremely accurate and reliable continuous measurements of very low concentrations of Hg in flue gas emissions. The SM-5 features short response times, dynamic ranges and stable measurement under all ...
-
Emissions - Permanent Samplers
-
ENVEA - Model Amesa-B - Continuous Monitoring of Biogenic CO2‚ Emissions
Biogenic or carbon-neutral stack CO2 gas can be deductible from any company’s greenhouse gas inventory which is required for reporting under various ...
-
ENVEA - Model Amesa-D - Dioxins and Furans Permanent Sampler
Continuous dioxin and furan emission monitoring by long-term sampling. TÜV and MCERTs certified, ETV EPA approved. The AMESA-D utilizes the water cooled probe method with Isokinetic sampling system coupled with XAD-II adsorbent cartridge for Long-term sampling of dioxins (PCDD), furans (PCDF) and other persistent organic contaminant (POPs). AMESA-D is the most utilized dioxin monitoring system worldwide in all ...
-
ENVEA - Model Amesa-M - Mercury Sorbent Trap System
Meets the US EPA Performances Standard 12 B mentioned in the US Portland Cement Rules and the new MATS (Mercury and Air Toxics ...
-
Emissions - Flue Gas Velocity CEMS
-
ENVEA - Model StackFlow 100 - Micro-Venturi Flue Gas Velocity CEM
Flue gas flowmeter for continuous measurement of gas velocity, temperature and pressure in exhaust gas ducts (chimneys or flue pipes). Micro-Venturi technology. The StackFlow 100 is a compact flowmeter for continuous measurement of velocity, temperature and static pressure in exhaust gas ducts ( stacks or flue gas ducts) using the Micro-Venturi technology. From these measurements, StackFlow 100 allows to determine the flue gas volume flow rate via an ...
-
Emissions - Sampling Systems
-
ENVEA - Model MVS - Multiplexing CEMS Management System
MVS 2M is a multichannel system allowing to distribute two, three or four channels of fluids and signals to a gas monitoring system (GMS). Its function is to link the GMS with the sampling systems for gas and span gas, and to allow the redundancy ...
-
ENVEA - Model HOFI BOX - Heated Sampling System
The HOFI BOX offers an exclusive sampling system dedicated to heated analyzers. Ideal for corrosive gases. (Plug & play sampling solution for: MIR FT, MIR 9000H, Graphite 52M, Topaze ...
-
ENVEA - Model SEC BOX - Stack Gas Sampling System
The dry extractive SEC system dries the gas sample at the sampling point, eliminating the necessity of an expensive heated sampling line. It uses an exclusive high performance permeation technique, designed to meet almost all gas sample conditions. Ideal for highly soluble and corrosive gases. Optional built-in temperature & velocity sensors or STACKFLOW 200 flow meter on the same ...
-
Emissions - Engine Exhausts Monitoring
-
ENVEA - Model LGD 2M - Laser Gas Detection Module NH3 (TDLS)
Rack 3U monitor using the TDL extractive technology to measure online the NH3 pre and/or post catalyst: SCR (Selective Catalytic Reduction) or SNCR (Selective Non-Catalytic Reduction) ENVEA is offering Laser Gas Detection (LGD) modules with exceptional advantages and value for the customer. Tunable Diode Laser Spectrometry (TDLS), enhanced by proprietary technology, is used for the measurement of CO2, NH3, CH4, HCl, ...
-
ENVEA - Model BERYL 92M FTUV - Ammonia (NH3) Analyzer (Fourier Transform technology)
Ultra-fast NH3 measurement (Ultra-fast response time : < 2 seconds). The use of the UV range for the measurement of NH3 has been specifically selected to avoid any interference with other major emission gases (CO, CO2, H2O etc..) that do not absorb in the ...
-
ENVEA - Model EGAS 2M - Engine Exhaust Gas Analysis Systems (EGAS)
The only system allowing the measurement of 1 or 2 independent streams in a single analysis ...
-
ENVEA - Model Mini DeNOx - Cabinet Heated Turnkey Gas Analysis System
Heated Turnkey Gas Analysis System ideally suited for fast, continuous and simultaneous measurements of NH3 and NOx in DeNOx applications (SCR and SNCR). In DeNOx systems using urea injection with ammonia (NH3) as a reducing agent, the flow rate and control of NH3 must be continuously adjusted and controlled to prevent excess NH3 emissions (slip), to reduce environmental impact and cost of reagents. To optimize this process, it is essential to use an ...
-
ENVEA - Model MIR 2M - CO, CO2 and O2 Multi-Gas Infra-Red Analyzer
Exists in single or dual stream version and “Ultra Low” version for low CO concentration measurements (0-10 to 0-50 ppm) Installed downstream a chiller, controlled at ...
-
Ambient - Air Quality Gas Monitors - O3
-
ENVEA - Model O342e e-Series - Ozone analyzer O3
LED based, UV Photometric Ozone Analyzer providing accurate, stable and repeatable O3 measurements in the range of 0-500 ppb or 0-10 ppm. Eco-designed, reference air quality monitor using patented technology. QAL1 certified by the TUV, US-EPA ...
-
ENVEA - Model O342e - e-Series Ozone analyzer O3
LED based, UV Photometric Ozone Analyzer providing accurate, stable and repeatable O3 measurements in the range of 0-500 ppb or 0-10 ppm. Eco-designed, reference air quality monitor using LED based UV Photometry technology (patented). QAL1 certified by the TUV, US-EPA ...
-
Ambient - Air Quality Gas Monitors - SO2
-
ENVEA - Model AF22e e-Series - Sulfur dioxide Analyzer SO2
UV Fluorescence gas monitor offering excellent performances for the monitoring of SO2 in the range 0-10 ppm or 0-1 ppm. Eco-designed, reference air quality monitor, QAL1 certified by the TÜV, US-EPA approved. Utilizes the standard method for the measurement of sulfur dioxides(EN 14212). With its ultra low power consumption & 24 V supply (option), the AF22e is the sole SO2 monitor on the market able to measure without being connected to the power ...
-
Ambient - Air Quality Gas Monitors - NO/NO2/NOx
-
ENVEA - Model AS32M - CAPS Nitrogen Dioxide Analyzer NO2
Gas monitor for fast, precise, direct and continuous measurement of NO2 concentrations in the range 0-1000 ppb. Visible (450 nm) absorption measurement using patented Cavity Attenuated Phase Shift (CAPS) technology. QAL1 certified by the TÜV, US-EPA approved. Fast and direct measurement of the sample – no chemical conversion required, no Toxic Gas ...
-
Ambient - Air Quality Gas Monitors - VOC
-
ENVEA - Model VOC72e - Volatil Organic Compounds Analyzer BTEX
Gas chromatography (GC) coupled with a PID detector. VOC monitor QAL1 certified to EN 14662-3 standard for benzene measurement. Compact and fully automated analyser providing equal performance to the laboratory chromatographs; particularly well-suited for fixed or mobile ambient air quality monitoring stations. Standard measured compounds: Benzene, Toluene, Ethylbenzene, m+p-Xylene, o-Xylene, 1-3 Butadiene (other compounds on ...
-
Ambient - Hg Monitors - Mercury
-
ENVEA - Model Mercury Tracker-3000 XS - All-in-One Portable Real-Time Hg Monitor
Very small, ultra-light, with on-board GPS, data logger, battery pack and color TFT display for very comfortable and easy mercury monitoring in ambient air and other gases. Portable mercury monitoring and detection is made easy with the Mercury Tracker 3000 XS. Lightweight, rugged construction and compact, the instrument is perfect for indoor and outdoor screening of mercury concentration in ambient air and detecting mercury spills. ...
-
ENVEA - Model MMS - Automatic Mercury Monitoring in Air and Gases
The MMS basically comprises a multiplexer-valve unit and a highly accurate and selective mercury detector (VM-3000 Vapor Monitor) for measurements in air and other gases. Each mercury on-line system will differ in sample characteristics as well as installation conditions and operating environment. We have the experience to design systems that fully meet the requirements of your particular mercury monitoring ...
-
Ambient air quality - Particulate monitors - PM10 / PM2.5
-
ENVEA - Model MP101M - Continuous, Automatic Suspended Particulate Monitor
PM10, PM2.5 and PM1 fine dust concentration measurement in the range 0-10,000 μg/m3 using the Standard Reference Method. The MP101M particulate analyzer uses the standard ISO 10473 beta gauge measurement method for the continuous measurement of the concentration of fine dust in ambient air. The instrument is certified equivalent to the reference method in accordance with the EN12341 European standards for measuring PM10 and PM2.5 respectively EN14907 ...
-
ENVEA - Model MP101M with OPM (Optical Particulate Monitor) - Automatic & Real-Time Particulate Monitor
Hybrid monitor utilizing ISO 10473 SRM Method & optical technology for Automatic & Real-Time measurement of PM10, PM2.5 and PM1 fine dust. The standard Beta gauge measurement Method ISO 10473 of the MP101M analyzer allows, when used with the patented optical technology of the OPM module, the continuous and simultaneous measurement of fine dust. Combination of both technologies provide a real-time indication of particles for PM10, PM2.5 and PM1 ...
-
Ambient air quality - Particulate Monitors
-
ENVEA - Model AirSafe 2 - Ambient Air Dust Monitoring
Continuous dust monitoring in ambient air: control system areas, silo areas, boiler houses, work stations. AirSafe 2 is an electrodynamic dust sensor monitoring leakages and dust concentration in ambient air in production facilities or workplaces. This versatile sensor allows you to keep under control your ambient environment. An alarm is generated when a threshold is ...
-
ENVEA - Model PM162M - Automatic Sequential Particulate Sampler
Designed to automatically sample particulates on filters using a TSP, PM10, PM2.5 or PM1 inlet. PM162M is a sequential automatic sampling device for particulate matter in the ambient air. The particles are sampled at constant flow rate (1 m3/h or 2.3 m3/h) and collected on filters for gravimetric weighing and possible physicochemical laboratory ...
-
Ambient - Air quality monitoring & Laboratory Mercury Instruments
-
ENVEA - Model UT-3000 NG - Mobile Mercury Ultratrace Analyzer for Natural Gas
Perfectly adapted to monitor the efficiency of different Mercury Removal Units (MRUs) in natural gas processing plants. Each mercury on-line system will differ in sample characteristics as well as installation conditions and operating environment. We have the experience to design systems that fully meet the requirements of your particular mercury monitoring ...
-
ENVEA - Model MMS-NG - Automatic Mercury Monitoring in Natural Gas
Automatic systemdesigned for continuous mercury monitoring in natural gas even in hazardous zones (ATEX, IEC-Ex). Each mercury on-line system will differ in sample characteristics as well as installation conditions and operating environment. We have the experience to design systems that fully meet the requirements of your particular mercury monitoring ...
-
ENVEA - Model AULA-254 Gold - Gold Automatic Laboratory Mercury Analyzer
The AULA-254 Gold is a fully automated system for analyzing traces of mercury in aqueous and digested samples. In contrast to a typical multi-element AAS the AULA is specially designed for mercury determination. The use of a highly stable low-pressure electrodeless mercury discharge lamp (EDL) in connection with the latest UV detector techniques result in excellent baseline stability and low detection limits. The AULA-254 Gold system meets current ...
-
ENVEA - Model LabAnalyzer 254 - Fast Mercury Determination in Analytical Applications
The LabAnalyzer is the perfect solution for quantitative determination of mercury in aqueous samples and sample digests in the laboratory. In contrast to a typical multi-element AAS the LabAnalyzer 254 is specially designed for elemental mercury. This allows top performance in analytical applications. The use of a specially developed highly stable mercury lamp in connection with thermostat-controlled UV sensors results in a detection limit of a few ppt of ...
-
ENVEA - Model UT-3000 - Total Gaseous Mercury (TGM) Ultratracer
Measuring of Total Gaseous Mercury (TGM) in air and other gases. Reliable for measurements at ultra-trace levels (sub-ng/m³) according to EN 15852. The UT-3000 operates automatically. All functions are controlled by an embedded microprocessor. When measurements are carried out, all parameters and results are stored in the integrated data logger. With standard settings the data logger has a recording capacity of 5000 measurements (approx. 2 ...
-
Ambient - Odors detection & Air quality monitoring Micro-Sensors
-
ENVEA - Model Cairsens PM - Miniature Solution for Real-Time Continuous PM1, PM2.5 & PM10 Monitoring
The last generation of Cairsens micro-sensors for Particulate Matters (PM) monitoring operates without any influence from moisture in ambient air. They measure PM1 and PM10 concentrations, with increased precision for PM2.5. The Cairsens allows a year of continuous maintenance-free operation, even in highly polluted and humid atmospheres. Thanks to its robust and miniature design, it is fully compatible with ENVEA’s turnkey AQMS station Cairnet. It ...
-
ENVEA - Model Cairsens nmVOC - Miniature Solution for Real-Time Continuous nmVOC Monitoring
The Cairsens© sensor allows specific pollutant measurement comparable to reference methods. The high quality sensors are renowned worldwide by our customers looking for the newest technologies in air quality monitoring. They offer precise and reliable measurement, and are calibrated using a reference-standard value. They come with a unique calibration certificate and don’t need any more calibration after installation during their lifetime ...